ChipFind - документация

Электронный компонент: 1N748A

Скачать:  PDF   ZIP
SYMBOL
VALUE
UNIT
Zener Current (see Table "Characteristics")
Power Dissipation at T
L
= 75C
P
tot
500
(1)
mW
Maximum Junction Temperature
T
j
175
C
Storage Temperature Range
T
S
65 to +175
C
NOTES:
(1) T
L
is measured 3/8" from body.
FEATURES
Silicon Planar Power Zener Diodes
Standard Zener voltage tolerance is 5% for
"A" suffix. Other tolerances are available upon
request.
MECHANICAL DATA
Case: DO-35 Glass Case
Weight: approx. 0.13 g
MAXIMUM RATINGS
Ratings at 25C ambient temperature unless otherwise specified.
1N746 THRU 1N759
ZENER DIODES
1/6/98
SYMBOL
MIN.
TYP.
MAX.
UNIT
Thermal Resistance
R
thJA
300
(1)
C/W
Junction to Ambient Air
Forward Voltage
V
F
1.5
Volts
at I
F
= 200 mA
NOTES:
(1) Valid provided that leads at a distance of 3/8" from case are kept at ambient temperature.
NEW PRODUCT
NEW PRODUCT
NEW PRODUCT
mi
n. 1.083 (
27.5)
mi
n. 1.083
(
2
7
.
5)
max
. .
150 (
3.8)
max.
Cathode
.020 (0.52)
Mark
max.
.079 (2.0)
DO-35
Dimensions are in inches and (millimeters)
1N746 THRU 1N759
ELECTRICAL CHARACTERISTICS
Ratings at 25C ambient temperature unless otherwise specified.
Type
Number
Nominal
Zener Voltage
V
Z
@ I
ZT
(3)
(Volts)
Test
Current
I
ZT
(mA)
Maximum Zener Impedance
Z
ZT
@ I
ZT
(1)
(
)
Maximum
Regulator Current
I
ZM
(2)
(mA)
Maximum Reverse Leakage Current
T
A
= 25C
I
R
@ V
R
= 1V
(
A)
T
A
= 150C
I
R
@ V
R
= 1V
(
A)
1N746A
3.3
20
28
110
10
30
1N747A
3.6
20
24
100
10
30
1N748A
3.9
20
23
95
10
30
1N749A
4.3
20
22
85
2
30
1N750A
4.7
20
19
75
2
30
1N751A
5.1
20
17
70
1
20
1N752A
5.6
20
11
65
1
20
1N753A
6.2
20
7
60
0.1
20
1N754A
6.8
20
5
55
0.1
20
1N755A
7.5
20
6
50
0.1
20
1N756A
8.2
20
8
45
0.1
20
1N757A
9.1
20
10
40
0.1
20
1N758A
10
20
17
35
0.1
20
1N759A
12
20
30
30
0.1
20
NOTES:
(1) The Zener Impedance is derived from the 1 KH
Z
AC voltage which results when an AC current having an RMS value equal to 10% of the Zener current (I
ZT
) is
superimposed on I
ZT
. Zener Impedance is measured at two points to insure a sharp knee on the breakdown curve and to eliminate unstable units.
(2) Valid provided that leads at a distance of 3/8" from case are kept at ambient temperature.
(3) Measured with device junction in thermal equilibrium.