ChipFind - документация

Электронный компонент: GI754

Скачать:  PDF   ZIP
GI750 THRU GI758
HIGH CURRENT PLASTIC RECTIFIER
Reverse Voltage - 50 to 800 Volts Forward Current - 6.0 Amperes
FEATURES
Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
High forward current capability
Diffused junction
Construction utilizes void-free
molded plastic technique
High surge current capability
High temperature soldering guaranteed:
250C/10 seconds, 0.375" (9.5mm) lead length,
5 lbs. (2.3kg) tension
MECHANICAL DATA
Case: Void-free molded plastic body
Terminals: Plated axial leads, solderable per MIL-STD-750,
Method 2026
Polarity: Color band denotes cathode end
Mounting Position: Any
Weight: 0.07 ounce, 2.1 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25C ambient temperature unless otherwise specified.
SYMBOLS
GI750
GI751
GI752
GI754
GI756
GI758
UNITS
Maximum repetitive peak reverse voltage
V
RRM
50
100
200
400
600
800
Volts
Maximum RMS voltage
V
RMS
35
70
140
280
420
560
Volts
Maximum DC blocking voltage
V
DC
50
100
200
400
600
800
Volts
Maximum non-repetitive peak reverse voltage
V
RSM
60
120
240
480
720
1200
Volts
Maximum average forward rectified current at
T
A
=60C, P.C.B. mounting
(FIG. 1)
6.0
T
L
=60C, 0.125" (3.18mm) lead length
(FIG. 2)
I
(AV)
22.0
Amps
Peak forward surge current
8.3ms single half sine-wave superimposed on
I
FSM
400.0
Amps
rated load (JEDEC Method)
Maximum instantaneous forward voltage at 6.0A
0.90
0.95
100A
V
F
1.25
1.30
Volts
Maximum DC reverse current
T
A
=25C
5.0
A
at rated DC blocking voltage
T
A
=100C
I
R
1.0
mA
Typical junction capacitance
(NOTE 1)
C
J
150.0
pF
Typical reverse recovery time
(NOTE 2)
t
rr
2.5
s
Typical thermal resistance
(NOTE 3)
R
JA
20.0
R
JL
4.0
C/W
Operating junction and storage temperature range
T
J
, T
STG
-50 to +150
C
NOTES:
(1) Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts
(2) Reverse recovery test conditions: I
F
=0.5A, I
R
=1.0A, Irr=0.25A
(3) Thermal resistance from junction to ambient and from junction to lead at 0.375" (9.5mm) lead length,
P.C.B. mounted with 1.1 x 1.1" (30 x 30mm) copper pads
10/12/98
0.052 (1.32)
0.048 (1.22)
0.360 (9.1)
0.340 (8.6)
DIA.
1.0 (25.4)
MIN.
0.360 (9.1)
0.340 (8.6)
1.0 (25.4)
MIN.
Case style P600
Dimensions are in inches and (millimeters)
0
20
40
60
80 100 120 140 160 180 200
0
20
40
60
80
100 120 140 160 180 200
0
4.0
8.0
12
16
20
24
28
1
0.01
0.1
1
10
100
0.1
1
10
100
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.01
0.1
1
10
100
10
100
600
100
50
0
20
60
80
100
100
10
1
0.1
0.01
40
RATINGS AND CHARACTERISTIC CURVES GI750 THRU GI758
FIG.1 - MAXIMUM FORWARD CURRENT
DERATING CURRENT
AMBIENT TEMPERATURE, C
A
VERA
GE FOR
W
ARD RECTIFIED CURRENT
,
AMPERES
60 H
Z
RESISTIVE or
INDUCTIVE LOAD
A
VERA
GE FOR
W
ARD CURRENT
,
AMPERES
LEAD TEMPERATURE,
C
T
J
=25C
PULSE WIDTH=300
s
1% DUTY CYCLE
FIG. 2 - MAXIMUM FORWARD CURRENT DERATING
CURVE
FIG. 3 - MAXIMUM PEAK FORWARD SURGE CURRENT
NUMBER OF CYCLES AT 60 H
Z
PEAK FOR
W
ARD SURGE CURRENT
AMPERES
T
J
=150C
NON-REPETITIVE
REPETITIVE
T
J
=25C
1.1 x 1.1" (30 x 30mm)
COPPER PADS
T
J
=25C
T
J
=150C
L=0.625"(15.8mm)
L=0.125" (3.18mm)
60 H
Z
RESISTIVE or
INDUCTIVE LOAD
BOTH LEADS
ATTACHED to HEAT
SINKS with LENGTH
as SHOWN "L"
L=0.25"
(6.35mm)
L=0.375"
(9.5mm)
T
J
=100C
T
J
=125C
T
J
=25C
V
RRM
may be APPLIED
BETWEEN EACH CYCLE of
SURGE, the T
J
NOTED is T
J
PRIOR to SURGE
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG. 4 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
INST
ANT
ANEOUS FOR
W
ARD CURRENT
,
AMPERES
FIG. 6 - TYPICAL TRANSIENT THERMAL IMPEDANCE
t, PULSE DURATION, sec.
TRANSIENT THERMAL
IMPED
ANCE,
C/W
FIG. 5 - TYPICAL REVERSE CHARACTERISTICS
PERCENT OF RATED PEAK REVERSE VOLTAGE, %
INST
ANT
ANEOUS REVERSE CURRENT
,
MICR
O
AMPERES