ChipFind - документация

Электронный компонент: LX24T3

Скачать:  PDF   ZIP
Technical Information
No. FO 5042
Linear Excimer Lamp
Edition: 03/03
- subject to change
Supersedes:
Status: initial
LINEX
LX24T3/956/A4
Photo Optics Berlin
Product description
The OSRAM LINEX
LX24T3/956/A4 is a dielectric barrier discharge lamp system. It consists of an aperture lamp
and an inverter. It is especially used for the exposure process in digital copiers and scanners. The lamp provides
an illuminance of 48,000 lux in white (triphosphor). The Xenon gas discharge enables instant light within a few
milliseconds. The light output shows no temperature dependence as well as a steady light emission. Since OSRAM
patented internal electrodes are used no high voltage isolation is needed.
235
15
15
2
8
2
3.1
11.5
5
13
13
Lamp technical data
1
Order reference
LX24T3/956/A4
Lamp overall length Lo
mm
267,5
System power consumption W 24
Inner emission length Li
mm
Lamp operating frequency
KHz > 80
80% of center illuminance
mm
180
Rated lamp voltage
KV < 3
Outer diameter base D
mm
Illuminance
2
Lx
48,000
Outer diameter glass tube
mm
10.0
Color coordinates
2
: x / y
0.324 / 0.336
Aperture
deg.
75
Maintenance >80%
Hrs. 1000
Lamp weight
g 24
Cable length mm
230
1
ambient room temperature of 25C
Note: lamp base design on customer request possible
2
measured at a distance of 8mm from the aperture by Minolta T-1M
DC-HV inverter technical data
1
Order reference
QT LINEX
1x24/24
Inverter size
Mm
135 (L) x 40 (W) x 28 (H)
Inverter weight G
110
Nominal/Min./Max. input voltage
Vdc
24 / 21.6 / 26.4
Nominal/Maximum input current
A
1.0 / 1.1
Typical input inrush current
3
A 2
3
switch on by lamp enable

The inverter provides an electrical pulse wave to the lamp.
The lamp system is covered by one or more of the following patents:
WO 94/23442, WO 98/49712. Other patents not listed may apply or pending.
75
Technical Information
No. FO 5042
Linear Excimer Lamp
Edition: 03/03
- subject to change
Supersedes:
Status: initial
LINEX
LX24T3/956/A4
Photo Optics Berlin
Lamp spectrum
0
1
2
3
4
5
6
350
400
450
500
550
600
650
700
750
800
850
wavelength [nm]
intensity

Connection drawing
+24V input
voltage
Enable
connected to ground = operating
open = non operating
0V ground
NC not
connected
Output
Input