ChipFind - документация

Электронный компонент: HMS91C7432

Скачать:  PDF   ZIP
Hynix semiconductor
1
INTRODUCTION
From now on, you can hook your product onto the inter-net directly.
Put the PC aside, HMS91C7432 do all the jobs that the PC do for
inter-net connection.
HMS91C7432 is a CMOS IC with a complete TCP/IP protocol suite to facilitate
inter-net connection for embedded application. The built-in email engine can
transform any ASCII message to standard email format. It sends and receives
email; conduct the whole log on process automatically. Built-in PPP protocol
handle user-ISP handshaking and authentication process automatically. The
HMS91C7432 also includes the MODEM driver, no code should write to drive
the MODEM (parameter of modem must be transferred by the host to make
HMS91C7432 works with your modem).
Using HMS91C7432 is easy, a simple 8 bit parallel port (8 bit data plus 4 control
lines) bridge the IC with your application. A serial DTE port is ready for directly
connect to an onboard modem or through DTE interface to a serial modem.
Make your product inter-net able, just add an HMS91C7432 on your BOM.
Hynix semiconductor
2
HMS91C7432 features and functions
z
Implementation of the complete TCP/IP protocol suite
z
Built-in Email sending and reception function.
z
Standard SMTP protocol stack.
z
Standard POP3 protocol stack.
z
Standard PPP protocol stack to facilitate dial-up network log on.
z
Standard DNS protocol stack, resolve URL with dynamic DNS server.
z
Serial modem driver built-in.
z
Support V.90 56Kflex modem or lower.
z
8 bit parallel interface to the user application.
z
Serial DTE port for ease of modem interface.
z
5V or 3.3V operation voltage
z
20 pins SOP package
Detail description of HMS91C7432 function and its application
TCP/IP protocol suite is the key to inter-net
access. Email; Home Page materials and all
the data traffic on the inter-net are carry out
by using the TCP/IP well defined format.
Time before HMS91C7432 exist, most inter-
net connection were to be handled by the PC.
Hand held devices and equipments must be
attached to the PC to get access to the
inter-net. Now the era of "PC-free" inter-net
connection has come. With HMS91C7432,
you can make your product be able to send
and receive email; surf on the WWW and
even "TALK" to another device through the
inter-net, by just plugging the telephone line
onto it.
The core of the HMS91C7432 is a complete
TCP/IP protocol suite. Files and messages
pass to the HMS91C7432 will be transformed
into the appropriate format and packets to
conform the inter-net standard. This
transformation is transparent to the user's
application.
On top of the TCP/IP core, there is an Email
engine built-in. User's program just needed
to inform the HMS91C7432 an email is going
to send and follow with the email body.
HMS91C7432 will then wake up the modem
and dial the ISP to log on the mail server. The
mail will be sent when log on has success.
HMS91C7432 complete this whole process
fully automatic.
Reception of Email is as simple as getting
email on the PC. The application program
send a "Receive Email" command to the
HMS91C7432, it dial up the ISP and log on
the server, then it check and download any
email automatically. Each message will be
stored in the RAM buffer, HMS91C7432 will
notify the application program an email has
come and waiting for retrieve.
The built-in PPP module handles the "Log on
process". This is a standard protocol to pass
the user's account ID and the password to
the ISP. This module handles the
authentication and "Handshaking". User's
program just pass the user's ID and
password to HMS91C7432 and the PPP do it
all.
HMS91C7432 (later version only) also equip
with a FTP module to facilitate file transfer
and file downloading from the FTP site. This
function is especially good for remote system
update and game download for hand-held
game inter-net access.
The standard serial DTE interface on the
HMS91C7432 ease the modem connection.
The built-in modem driver support V.90 and
56K flex dual modem or lower.
HMS91C7432 is controlled by an 8 bit
data/command port. This port accepts
command passed by the host MCU.
Incoming and outgoing message will be
passed between the host and the
HMS91C7432 through this port as well.
Hynix semiconductor
3
Specifications of HMS91C7432
The HMS91C7432 TCP/IP communication controller is manufactured in advance CMOS
process.
The HMS91C7432 implement complete TCP/IP protocol suite includes PPP; IP; ICMP;TCP;
UDP; DNS; SMTP; POP3 protocol and additionally a general MODEM driver.
The HMS91C7432 is built-in with 96Kb SRAM (12K x 8) for communication and buffering, A full
duplex UART as DTE for ease of serial modem connection.
The HMS91C7432 has an 8 bits Data/Command port and 4 control pins to facilitate control and
communication between the Host MCU and the modem. There are only 20 simple commands,
each of which is a single byte long, to establish and to complete the whole internet
communication. 45 respond codes for the Host MCU to monitor the communication status.
Extremely low external component count. Very low power consumption.
Features :
y
Implement TCP/IP protocol suit.
y
SMTP for sending email
y
POP3 for receiving email
y
PPP for dialup network log on
and hand shaking.
y
DNS protocol to resolve IP
address from URL
y
Full static operation
y
Full Duplex 56K/115Kbps UART
port for modem DTE connection.
y
Speed range up to 22.118MHz
y
8 bits Bi-directional Data/Command bus.
y
Modem driver included
y
Power control modes
9
Active mode
9
Power-down
mode
y
Dissipating
Current
Active 25mA
Power-down
10uA
max.
y
20 single byte easy commands
y
45
respond
codes
y
Package type 20-SOP
y
Operating voltage
3.3V +/- 10%
Dissipating Current
Active mode
25 mA
Power down mode
10uA max.
Oscillation Frequency
11.0592 Mhz
Operating Temperature
-40 to +85
C
Storage Temperature
-65 to +150
C
D0
D1
D2
D3
D4
D5
D6
D7
Test
VCC
RXD
TXD
Reset
Strobe
WR
INT
Wait
Xtal 2
Xtal 1
Vss
HMS91C7432
SOP 20
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
13
12
11
Hynix semiconductor
4
Specifications of HMS91C7432
MNEMONIC
PIN
TYPE
NAME AND FUNCTION
Vss
14
Ground : 0V reference.
Vcc
9
Power Supply : This is the power supply voltage for
normal, and power-down operation.
D0 to D7
1 8
I/O
Data/Command Port : This is an 8 bit bi-directional I/O
port with internal pull-ups. This port is for data transfer
between Host MCU, it also serves as command reception
and responds code issuance port from and to the Host
MCU.
WAIT
14
Out
WAIT : Handshake signal. When low it indicates that is
OK to start a cycle (assert a strobe), when high it
indicates that it is OK to end the cycle (de-assert a
strobe).
INT
15
Out
INT : Active LOW Output a request to the Host MCU if
data/respond code are to be sent.
WR
16
In
WRITE : Active LOW write enable pin.
Set this pin LOW
for a write cycle. Set this pin HIGH for a read cycle.
STROBE
17
In
STROBE : Data strobe signal.
Active low indicates a
Data_Read or Data_Write operation is in process.
RXD
20
In
RXD : UART serial input port.
TXD
19
Out
TXD : UART serial output port.
RESET
13
In
RESET : A high level on this pin for 2us while the
oscillator is running resets the device.
TEST
10
In
TEST : Test pin, should be stuck at zero when normal
operation.
XTAL 1
11
In
XTAL1 : Input to the inverting oscillator amplifier and
input to the internal clock generator circuits.
XTAL 2
12
Out
XTAL2 : Output to the inverting oscillator amplifier.
Table 1. Pin descriptions
Hynix semiconductor
5
Figure 1. Data Write Cycle waveform
WR
Strobe
Wait
Data[7:0]
1 2 3 4 5 6
Valid data
Specifications of HMS91C7432
Data Write cycle phase transitions:
1. The Write line is asserted and the data is output to the parallel port
2. The data strobe is asserted, since WAIT is asserted low
3. The port waits for the acknowledge from the HMS91C7432 (WAIT de-asserted)
4. The data strobe is de-asserted
5. The write cycle ends
6. WAIT is asserted low to indicate that the next cycle may begin
Data Read cycle phase transitions:
1. The Write line is set to HIGH to indicate read request
2. The data strobe is asserted, since WAIT is asserted low
3. The port waits for the acknowledge from the HMS91C7432 (WAIT de-asserted)
4. The data strobe is de-asserted after data is stored and the read cycle ends
5. WAIT is asserted low to indicate that the next cycle may begin
Figure 2. Data Read Cycle waveform
WR
Strobe
Wait
Data[7:0]
1 2 3 4
5
Valid data
Hynix semiconductor
6
Specifications of HMS91C7432
(Ta = -20 To +85 , Vcc = 5V 10%, Vss = 0V)
t
DC Characteristics
SYMBOL
PARAMETER
UNIT
LIMITS
Vcc+0.5
-0.5
MIN
MAX
CONDITIONS
TEST
V
V
IL
Input low voltage,except Reset
V
IH1
Input high voltage,Xtal1
V
IH
Input high voltage,except Xtal1,Reset
0.2Vcc-0.1
0.7Vcc
Vcc+0.5
V
V
V
OL
Output low voltage,D0~D7,Strobe,
WR,INT,Wait
1.0
V
V
OH
Output high voltage, D0~D7,Strobe,
WR,INT,Wait
I
OH
= -25
A
0.75Vcc
V
I
IL
Logical 0 input current, D0~D7,Strobe,
WR,INT,Wait
V
IN
= 0.45V
A
-50
I
TL
Logical 1-to-0 input current,
D0~D7,Strobe,WR,INT,Wait
V
IN
= 3.0V
A
-650
I
CC
Power supply current :
Active mode@11.0592MHz
Power-down mode @11.0592MHz
16
10
A
mA
-0.5
V
V
IL1
Input low voltage,Reset
0.2Vcc+0.1
V
IH2
Input high voltage, Reset
0.6Vcc
Vcc+0.5
V
I
OL
= 3.5mA
-10
-65
Vcc = 5V
NOTES :
1. See Figure 3 through 5 for Icc test conditions. Minimum Vcc for power down is 2V.
2. Under steady state (non-transient) conditions,I
OL
must be externally limited as follows :
Maximum I
OL
per port : 10mA
Maximum I
OL
per 8-bit port D0~D7,Strobe,WR,INT,Wait : 15mA
Maximum total I
OL
for all output pins : 71mA
If I
OL
exceeds the test condition,V
OL
may exceed the related specification.Pins are not
guaranteed to sink current greater than the listed test conditions.
0.7Vcc
Hynix semiconductor
7
Specifications of HMS91C7432
(Ta = -20 To +85 , Vcc = 3.3V 10%, Vss = 0V)
t
DC Characteristics(Cont.)
SYMBOL
PARAMETER
UNIT
LIMITS
Vcc+0.3
-0.5
MIN
MAX
CONDITIONS
TEST
V
V
IL
Input low voltage,except Reset
V
IH
Input high voltage,except Xtal1,Reset
0.8
0.7Vcc
V
V
OL
Output low voltage,D0~D7,Strobe,
WR,INT,Wait
0.45
V
OH
Output high voltage, D0~D7,Strobe,
WR,INT,Wait
I
OH
= -20
A
2.7
V
I
IL
Logical 0 input current, D0~D7,Strobe,
WR,INT,Wait
V
IN
= 0.45V
A
-50
I
TL
Logical 1-to-0 input current,
D0~D7,Strobe,WR,INT,Wait
V
IN
= 2.0V
A
-250
I
CC
Power supply current :
Active mode@11.0592
Power-down mode
10
10
A
mA
I
OL
= 1.6mA
V
-6
-40
Vcc = 3.3V
-0.5
V
V
IL1
Input low voltage, Reset
0.8
Vcc+0.3
V
IH1
Input high voltage,Xtal1
0.7Vcc
V
Vcc+0.3
V
IH2
Input high voltage,Reset
0.6Vcc
V
Hynix semiconductor
8
Specifications of HMS91C7432
DC Characteristics(Cont.)
Vcc
Icc
Vcc
Reset
Xtal2
Xtal1
Vss
(NC)
CLOCK
SIGNAL
Figure 3. Icc Test Condition,Active Mode
Vcc
Icc
Reset
Xtal2
Xtal1
Vss
(NC)
Figure 4. Icc Test Condition,Power Down Mode
All other pins are disconnected.
All other pins are disconnected.
Vcc-0.5
0. 5V
0.7Vcc
0.2Vcc-0.1
tCHCL
tCLCX
tCLCH
tCHCX
tCLCL
Figure 5. Clcok signal Wavefoerm for Icc Tests in Active Mode
tCLCH = tCHCL = 5ns
NOTES :
1. Icc(active mode) is measured with:
Xtal1 driven with tCLCH = tCHCL = 5ns, VIL = Vss + 0.5V, VIH = Vcc - 0.5V, X2 = N.C.
Reset = Vcc, all other pins are disconnected.
Icc would be slightly higher if a crystal oscillator is used (appr. 1mA)
2. Icc(power down mode) is measured with:
Xtal1 = Vss, Xtal2 = N.C., Reset = Vss, all other pins are disconnected.
Hynix semiconductor
9
Specifications of HMS91C7432
AC ELECTRICAL CHARACTERISTICS
(Ta = -20
o
C To +85
o
C, Vcc = 5.0V + 10%, 3.3V + 10%, Vss = 0V)
High Time
Symbol
Parameter
Min
Max
Min
Max
Unit
1/t
CLCL
t
CHCX
t
CLCX
t
CLCH
t
CHCL
Osc. Feq.
Low Time
Rise Time
Fall Time
5.0V +/- 10%
3.3V +/- 10%
MHz
ns
ns
ns
ns
EXTERNAL CLOCK DRIVE
3.5
25
3.5
20
20
20
20
20
25
25
15
15
Vcc-
0.45
t
CLCX
t
CLCH
t
CHCX
t
CLCL
0.7V
0.2Vcc-
t
CHCL
EXTERNAL CLOCK DRIVE WAVEFORM
Hynix semiconductor
10
Specifications of HMS91C7432
Data format for communication between HMS91C7432 and the host MCU
Sync 1
0x7E
Sync 2
0xFE
Contro
l code
Length Data 0
Max 131 bytes for data
Data 130
Data
ID
Data
flag
Reserv
ed
Data 0
Max 128 bytes for data
Data
127
Figure 3. Data packet format
Field description :
Field
Description
Value
Sync 1
Synconization for start of Command/Data packet.
Always set to 0x7E
Sync 2
As above
Always set to 0xFE
Control code
This is the command code field in simple command
mode. Specify the "Type of command" in complex
command mode.
In simple command
mode 0x80 ~ 0x89.
In complex command
mode 0x00 ~ 0x06
Refer to table 3
Length
Specify the length of the Data field.
0 ~ 131
Data fields
Max. length of 131 octets for each packet containing
structures for complex command data; setup
parameters; reponse code and mail text contents in
various communication mode accordingly.
Refer to the explaination
of the communication
mode.
Data ID
Specify the types of data containing in the current
packet.
0x00 ~ 0x34
refer to the table 4
Data Flag
Specify whether the current packet is the last packet or
more packet follow.
0x00 more packet follow
0x01 last packet
Reserved
Reserved for test purpose. Disregard this field in
normal operation.
Not applicable
Data 0 ~ 127 Contain max 128 octets of data
Single byte data
Table 2. Field descriptions for communication packet
Hynix semiconductor
11
Specifications of HMS91C7432
Table 3. Listing of Control Code
Control
Code
Description
Direction
0x00
Use this control code for complex command mode and mail text
transfer. This is a bi-directional command code. HMS91C7432
uses this code to pass mail's information and mail's body to the
host.
Bi-directional
depending on
the Data ID
0x01
For HMS91C7432 to issue complex command to the host to
request for Line Connection Info (refer to Table 5 for Info Listing).
HMS91C7432
To Host
0x02
For HMS91C7432 to issue Result Code to the host (refer to Table
6 for Result Code Listing).
HMS91C7432
To Host
0x03
For HMS91C7432 to issue the Connection Status to the host
(refer to Table 7 for Connection Status Listing). The issuance of
the Connection Status is in respond to the Host's request using
Control Code 0x04 in the complex command mode.
HMS91C7432
To Host
0x04
Host use this control code to request the report for Connection
Status. This code is to be used in Simple Command mode.
Host to
HMS91C7432
0x05
Host use this control code to request the report for SMTP
Processing Status. This code is to be used in Simple Command
Mode.
Host to
HMS91C7432
0x06
For HMS91C7432 to issue the SMTP Processing Status (refer to
Table 8 for the SMTP Status Listing). The issuance of the SMTP
Processing Status is in respond to the Host's request using
Control Code 0x05 in the complex command mode.
HMS91C7432
To Host
0x80
Initiate Modem host's command in Simple Command mode.
Instruct the HMS91C7432 to initialize the Modem and send the
pre-set AT initializing string. This command must be issued after
the AT initializing string has been passed.
Host to
HMS91C7432
0x81
Terminate host's command in Simple Command mode. Instruct
the HMS91C7432 to terminate the current process.
Host to
HMS91C7432
0x82
Log In ISP host's command in Simple Command mode. Instruct
the HMS91C7432 to Login to the ISP. When the command is
accepted, HMS91C7432 will run the login process automatically
and report to the host by using Control Code 0x02 complex
command. The whole login process consists of the following
steps, and Connection Status will be reported on each step.
1.
Modem off hook
2.
Dial up ISP
3. Modem
handshake
4.
Logon and authentication check using PPP
The Login process ends when the authentication check is passed
or in any cases a connection failure occurs.
This command must be issued after the Login information have
been passed, otherwise, HMS91C7432 will issue request using
Control Code 0x01 for missing info.
Host to
HMS91C7432
Hynix semiconductor
12
Specifications of HMS91C7432
Continue of Table 3. Listing of Control Code
0x83
Quit ISP Host's command in Simple Command mode. Instruct
the HMS91C7432 to end the current ISP session. When the
command is accepted, HMS91C7432 will run the Disconnect
process automatically and report to the host by using Control
Code 0x02 complex command. The whole Disconnect process
consists of the following steps, and Connection Status will be
reported on each step.
1.
Quit the ISP internet connection
2.
Disconnect the telephone line
3.
Hang up the modem and modem go On Hook
The Quit process ends when the modem responds with On Hook
OK, or in any cases a connection failure occurs.
Host to
HMS91C7432
0x84
Login SMTP Server - Host's command in Simple Command
mode. Instruct the HMS91C7432 to login to the dedicated SMTP
server. Upon the command is accepted, HMS91C7432 will run the
following steps, and Connection Status will be reported on each
step.
1.
Run DNS protocol to resolve for the SMTP server's IP
address.
2.
Register to the SMTP server.
The Login SMTP process ends when the SMTP server returns an
OK response code, or in any cases a Logon failure occurs.
Host to
HMS91C7432
0x85
Quit SMTP Server - Host's command in Simple Command mode.
Instruct the HMS91C7432 to end the current SMTP session. Upon
the command is accepted, HMS91C7432 will quit the SMTP
Server and keep ON LINE (keep connection with the internet).
Quit SMTP OK will be reported to the host by using Control Code
0x02 complex command.
Host to
HMS91C7432
0x86
Send Mail Request - Host's command in Simple Command
mode. Instruct the HMS91C7432 to get permission from the
SMTP server for sending mail. Upon the command is accepted,
HMS91C7432 will run the following steps, and Connection Status
will be reported on each step.
1.
Send the "Send Mail" request to the SMTP server
2.
Pass Sender email address; Recipient email address
to the SMTP server for validation.
3.
Wait for permission to send the mail's body.
When the SMTP server accept all the mail info and an OK to send
is received, HMS91C7432 will issue Ready to send response
using Control Code 0x02 to the host. DO NOT send the mail body
before this response is issued.
Host to
HMS91C7432
Hynix semiconductor
13
Specifications of HMS91C7432
Continue of Table 3. Listing of Control Code
0x87
Login POP3 server - Host's command in Simple Command
mode. Instruct the HMS91C7432 to login to the dedicated POP3
server. Upon the command is accepted, HMS91C7432 will run the
following steps, and Connection Status will be reported on each
step.
1.
Run DNS protocol to resolve for the POP3 server's IP
address.
2.
Register to the POP3 server and run the authentication
check process
3.
If authentication check is passed, request the POP3
server to return the number of mail contain in the
mailbox.
4.
If UIDL option is set (refer to Table 4 for explanation of
UIDL option), request the POP3 server to return the
Length and UID for each mail in the mailbox.
The Login POP3 process ends when the POP3 server returns the
number of mail and or the UIDL, or in any cases a Logon failure
occurs. Upon receipt of the "Number of Mail" info and the UIDL
info, HMS91C7432 will pass these info to the host by using
Complex Command mode with Control Code 0x00.
The Login POP3 command must be issued after the POP3 Login
information have been passed, otherwise, HMS91C7432 will
issue request using Control Code 0x01 for missing info.
Host to
HMS91C7432
0x88
Quit POP3 Server - Host's command in Simple Command mode.
Instruct the HMS91C7432 to end the current POP3 session. Upon
the command is accepted, HMS91C7432 will quit the POP3
Server and keep ON LINE (keep connection with the internet).
Quit POP3 OK will be reported to the host by using Control Code
0x02 complex command.
Host to
HMS91C7432
0x89
Shut Down HMS91C7432 - Host's command in Simple
Command mode. Instruct the HMS91C7432 to enter the Power
Down mode. Make sure the SMTP session or the POP3 session is
terminated and the line is disconnected before the Shut Down
command is issued.
Host to
HMS91C7432
Hynix semiconductor
14
Specifications of HMS91C7432
Table 4. Listing of Data ID
Data ID
Description
Command mode
0x00
Baud rate for HMS91C7432 serial UART port setting.
Host command
0x01
Modem AT initialize string
""
0x02
Modem Result Code listing
""
0x03
HMS91C7432 clock selection
""
0x04
POP3 UIDL return option
""
0x05~0x20 Reserved by the system. Do Not Use.
""
0x21
Telephone Number for dialup network.
""
0x22
User ID for the dialup network account
""
0x23
Password for the dialup network account
""
0x24
IP address for the DNS server (if not specified, dynamic DNS
server search will be used).
""
0x25
SMTP port (if not specified, use default value port 25)
""
0x26
POP3 port (if not specified, use default value port 110)
""
0x27
SMTP server domain name
""
0x28
POP3 server domain name
""
0x29
User ID for POP3 account
""
0x2A
Password for POP3 account
""
0x2B
Sender's email address
""
0x2C
Recipient's email address
""
0x2D
Mail text body
Host command /
HMS91C7432
data returns
0x2E
Reserved
N.A
0x2F
Reserved
N.A.
0x30
Number of mail in POP3 server
HMS91C7432
returns
0x31
UID listing
HMS91C7432
returns
0x32
Get Mail (followed with the mail number)
Host command
0x33
Delete Mail from server (followed with the mail number)
Host command
0x34
Get UID for a particular mail on the server (followed with the
mail number)
Host command
Hynix semiconductor
15
Specifications of HMS91C7432
Table 5. Listing of Info code for complex request mode made by HMS91C7432
Data ID
Description
Data_ID.0
Requesting Recipient's and Sender's email address
Data_ID.1
Requesting Password for POP3 account
Data_ID.2
Requesting User ID for POP3 account
Data_ID.3
Requesting Domain Name for POP3 server
Data_ID.4
Requesting Domain Name for SMTP server
Data_ID.5
Requesting Password for dialup network account
Data_ID.6
Requesting User ID for dialup network account
Data_ID.7
Requesting Telephone number for dialup account
Note on use: Whenever the HMS91C7432 needs network connection info, and it is missing or
corrupted in HMS91C7432 memory, HMS91C7432 will issue a request using complex
command mode with Control Code 0x01 following with the above Data ID for necessary
information return. Each bit of the Data ID, if set, indicates the co-responding info is needed.
Table 6. Listing of Response Code issued by HMS91C7432
In respond to the host's command, the HMS91C7432 always return the following Response
Code by using complex command mode with Control Code 0x02. The time taking to a response
is variable and mostly depending on the physical connection and the network traffic. Make sure
a response code is received before issuing a new command.
Response
Code
Description
Related layer and
protocol
0x40
Modem is ready
Modem initialization
0x41
Connected modem is connected to the remote terminal
Modem Dialup
0x42
Modem not ready modem is not presented or modem does
not return a correct response
Modem initialization
0x43
No Carrier No carrier signal is detected. Modem will hang
up automatically.
Modem Dialup
0x44
Error Modem internal error or unknown modem error.
Modem Dialup
0x45
No Dial tone No dial tone is detected. Possibly the phone
line is not connected.
Modem Dialup
0x46
Busy Line is busy.
Modem Dialup
0x47
No answer phone is no answer
Modem Dialup
0x48
Modem Hang Up The modem is disconnected.
Modem Dialup
0x49
Internet Logon OK The internet account authentication is
passed, Logon success.
PPP
Hynix semiconductor
16
Specifications of HMS91C7432
Continue to Table 6. Listing of Response Code issued by HMS91C7432
0x4A
ISP No Response ISP has no response after a long time
out.
PPP
0x4B
Authentication Fail Invalid User ID or invalid password
PPP
0x4C
Logon Fail Unable to logon to the internet for other reason PPP
0x4D
Internet Quit OK Disconnect from the internet and go Off
Line.
PPP
0x4E
Reserved
0x4F
Reserved
0x50
Mail Sent OK a mail is sent successfully
SMTP
0X51
SMTP Logon Fail Fail to logon to the SMTP server
SMTP
0x52
Mail Received OK A mail is received successfully
POP3
0x53
POP3 Logon Fail Fail to logon to the POP3 server
POP3
0x54
POP3 Authentication Fail Invalid POP3 User ID or invalid
POP3 password
POP3
0x55
Transmission Data Error Data passed to the server is not
accepted (e.g. un-resolvable email address)
SMTP
0x56
Reception Data Error Invalid data is received.
POP3
0x57
NO New Mail POP3 mail box is empty
POP3
0x58
SMTP Logon OK Successfully Logon to the SMTP server SMTP
0x59
POP3 Logon OK Successfully Logon to the POP3 server POP3
0x5A
DNS Fail Unable to locate DNS server or DNS server return
invalid data
DNS
0x5B
SMTP Quit Exit SMTP server
SMTP
0x5C
POP3 Quit Exit POP3 server
POP3
0x5D
Mail Deleted A mail is deleted from the POP3 mail box
POP3
0x5E
Mail Deleted Fail Unable to delete the mail, either the mail
number is not exist or the mail is locked by the server
POP3
0x5F
Wrong Mail Number The mail number not exist in the
mailbox.
POP3
0x60
SMTP Ready to Send HMS91C7432 is ready to accept
next packet of the mail text body.
SMTP
0x61
SMTP Buffer Overflow HMS91C7432 outgoing buffer is
full. Last packet received is invalid. Host must resend the
previous packet.
SMTP
0x62
SMTP Buffer full HMS91C7432 outgoing buffer is nearly
full and can not accept more data. The last packet is
accepted.
SMTP
Hynix semiconductor
17
Specifications of HMS91C7432
Table 7. List of Response Code for Network Status
Upon receipt of a "Network Status Request" issued by the host with Control Code 0x04, the
HMS91C7432 respond the request by returning the following code using complex command
mode with Control Code 0x03.
Response
Code
Mnemonics
Descriptions
0x00
Wait
Network is on hold or in processing, waiting for the
network to return instruction or data.
0x01
Dialing
HMS91C7432 is connecting the internet service.
0x02
Logon ISP in progress
Passing Logon info and authentication check in
progress
0x03
Logon ISP OK
System is On Line and the network is connected.
0x04
Logon SMTP in progress
Resolving SMTP IP address and waiting for SMTP
server to respond.
0x05
Logon SMTP OK
System has logon to the SMTP server. Ready to send
mail (send the mail header for validation first).
0x06
Mail Header is accepted
SMTP server has validated the addresses
0x07
Sending Mail
Sending Mail in progress
0x08
Quitting SMTP server
Quit command has been issued to the SMTP server,
waiting for response.
0x09
Logon POP3 in progress
Resolving POP3 server's IP address and waiting for
the result of the authentication check.
0x0A
Logon POP3 Ok
System has logon to the POP3 server.
0x0B
Getting Uid
Waiting for return of Unique ID of a mail.
0x0C
Requesting Mail
Mail request was sent, waiting for server to return
mail.
0x0D
Retrieving Mail
Mail reception in progress.
0x0E
Deleting Mail
Delete Mail request was sent, waiting for server to
return result.
0x0F
Quitting POP3 server
Quit command has been issued to the POP3 server,
waiting for response.
0x10
Network disconnecting
Quit command has been issued to the ISP, waiting for
server to respond.
0x11
Modem disconnecting
Hanging up the modem and waiting for the modem to
respond.
Hynix semiconductor
18
Specifications of HMS91C7432
Table 8. List of SMTP status response
HMS91C7432 return the following response code when the host makes a
request by using simple command mode with control code 0x05. HMS91C7432
return the response by using complex command mode with control code 0x06.
Response
code
Mnemonics
Description
0x60
SMTP Ready to Send
HMS91C7432 is ready to accept next packet of the mail
text body.
0x61
SMTP Buffer Overflow
HMS91C7432 outgoing buffer is full. Last packet
received is invalid. Host must resend the previous packet.
0x62
SMTP Buffer full
HMS91C7432 outgoing buffer is nearly full and can not
accept more data. The last packet is accepted.
Examples of inter-chip communication session:
Example 1. Commands issued by the host using Simple Command Mode
Sync 1
Sync 2
Control code
Length
0x7E
0xFE
0x80 ~ 0x89
0x00
The following command string instructs the HMS91C7432 to logon to the ISP
0x7E
0xFE
0x82 0x00
Example 2. Command issued by the host that using Complex Command Mode
Sync 1 Sync 2 Control Length Data ID Data Flag Reserved Data 0 ................ Data 127
0x7E
0xFE
0x00
Value 0 ~ 34h 0 or 1
NA
The following command string instructs the HMS91C7432 to retrieve a the mail #2 from the
POP3 server. Note that the Mail number must be defined as an integer (2 bytes long).
Sync 1
Sync 2
Control Length
Data ID Data Flag Reserved Data 0
Data 1
0x7E
0xFE
0x00
0x05
0x32
0x01
0x00
0x00
0x02
Example 3. A packet of mail text body received from HMS91C7432
This packet is passed from the HMS91C7432 in Complex Data Mode, Data ID 0x2D indicate
that the packet contain portion of a mail body. Data Flag is `0' indicates that more packet will
follow. Length is `0x83' indicates that there are 131 bytes after the length field. The actual text
data occupy 128 bytes only. Use the same format to pass outgoing mail body to the
HMS91C7432.
Sync 1 Sync 2 Control Length Data ID Data Flag
Reserved
Data 0 Data 1
........
Data 127
0x7E 0xFE
0x00
0x83
0x2D
0
0
T
e
Ascii
x
Hynix semiconductor
19
Specifications of HMS91C7432
Example 4. HMS91C7432 request for missing connection info
When the HMS91C7432 is going to make a connection to the internet or to a mail server, it will
check if all necessary info is available. The connection info may be erased due to memory
overlaying. Upon an internet session is ended, HMS91C7432 will clear its memory pool for
another session. Whenever connection info is needed, HMS91C7432 will issue a request to the
host for such info. The request will be made using complex command mode with control code
0x01 followed by a Data ID as listed in Table 5.
Sync 1
Sync 2
Control
Length
Data ID
0x7E
0xFE
0x01
0x01
0x08
This example demostrates a request made by the HMS91C7432 for the POP3 server's domain
name when it is going to logon to the POP3 server.
Example 5. HMS91C7432 returning result code to the host
There are sets of Result Code coresponding to each command issued by the host to the
HMS91C7432. The HMS91C7432 returns at least one result code to each command, to report
the result of execution or the status of the connection. HMS91C7432 returns the result code by
using complex command mode with control code 0x02 followed by the result code (in the Data
ID field) as listed in Table 6.
Sync 1
Sync 2
Control
Length
Data ID
0x7E
0xFE
0x02
0x01
0x49
This example demonstrates a result code returned from HMS91C7432 to report that the
authentication check is passed and the system is ON LINE (Logon to the ISP is success).
Example 6. Host requesting Connection Status and the HMS91C7432 returns
User may make a request for the connection status at any time during the internet session. The
host may make its request by using Simple Command Mode with Control Code 0x04. The
HMS91C7432 will return the connection status by Complex Command Mode with Control Code
0x03 followed by the connection status code as listed in Table 7.
This example demonstrates how the host makes a connection status request and how the
HMS91C7432 responds to this request. The host made the request after a successful logon to
the POP3 server. The HMS91C7432 report that the system has logon to the POP3 server.
Host requesting command format:
Sync 1
Sync 2
Control
Length
0x7E
0xFE
0x04
0x00
HMS91C7432 return the connection status:
Sync 1
Sync 2
Control
Length
Data ID
0x7E
0xFE
0x03
0x01
0x0A
Hynix semiconductor
20
Specifications of HMS91C7432
Example 7. Host requesting SMTP Connection Status and the HMS91C7432 returns
When sending out an email during SMTP session, the host should know when can it pass the
mail header and when can it pass the mail body to the HMS91C7432. Usually, depending on the
traffic of the network, it takes a longer time to be successfully logon to the SMTP server. The
host should frequently check the connection status to determine the time to pass the mail
header or to determine when to terminate the logon process if a time out is up. The host may
make such a report by using Simple Command Mode with Control Code 0x05. The
HMS91C7432 will return the SMTP connection status by Complex Command Mode with Control
Code 0x06 followed with the SMTP status code as listed in Table 8.
This example demonstrates how the host makes a SMTP connection status request and how
the HMS91C7432 responds to this request. The host made the request after a successful logon
to the SMTP server. The HMS91C7432 report that it is ready to accept the mail body. If the
request is made during the mail sending session, the following connection status indicates the
HMS91C7432 is ready to accept more packets (Outgoing buffer is not full).
Host requesting command format:
Sync 1
Sync 2
Control
Length
0x7E
0xFE
0x05
0x00
HMS91C7432 return the connection status:
Sync 1
Sync 2
Control
Length
Data ID
0x7E
0xFE
0x06
0x01
0x60
Hynix semiconductor
21
Specifications of HMS91C7432
Plastic Package P-DIP-20
(Plastic Dual In Package)
UNIT : INCH
* 1.043
1.010
* 1.043
1.010
0.180MAX
0.100 PITCH 0.140
0.120
0.021
0.015
**0.270
0.245
0.065
0.050
0.015MIN
0.014
0.008
0
~
15
0.300BSC.
**0.270
0.245
- NOTE -
1. DIMENSION * MARK DOES NOT INCLUDE MOLD
PROTRUSION
MAXIMUM ALLOWABLE PROTRUSION IS 0.010 INCH
PER SIDE.
2. DIMENSION ** MARK DOES NOT INCLUDE MOLD
Hynix semiconductor
22
Specifications of HMS91C7432
Plastic Package P-SOP-20
(Plastic Small Outline
Package)
UNIT : INCH
0.419
0.398
* 0.5118
0.4961
0.020
0.013
0.050 PITCH
0.104
0.093
0.0118
0.004
* 0.5118
0.4961
0.0125
0.0091
0.042
0.016
**0.299
0.291
* *0.299
0.291
- NOTE -
1. DIMENSION * MARK DOES NOT INCLUDE MOLD PROTRUSION
MAXIMUM ALLOWABLE PROTRUSION IS 0.006 INCH PER SIDE.
2. DIMENSION ** MARK DOES NOT INCLUDE MOLD PROTRUSION
MAXIMUM ALLOWABLE PROTRUSION IS 0.010 INCH PER SIDE.
3. DIMENSIONING AND TOLERANCING PER ANSI Y14.5M-1982
Hynix semiconductor
23
Application examples
0
RGHP
+06<4&:
765
(0$,/
&+,3
Host MCU
for
embedded
application
LCD panel
Keyboard
RAM
EEPROM
An example block diagram for a Data Bank Email Composer
0
RGHP
+06<4&:
765
(0$,/
&+,3
Host MCU
for home
appliance
control
LCD panel
Keyboard
Fan m
o
to
r
Heat
e
r
cooler
Hynix semiconductor
24
6SHDN
HU
3KRQH 0
RGHP
+06<4&:
765
(0$,/
&+,3
Host MCU
for
embedded
application
LCD panel
Keyboard
RAM
EEPROM
An example block diagram for an Email Phone
M