ChipFind - документация

Электронный компонент: IZ7007

Скачать:  PDF   ZIP
IZ7007
1
Circuit for electron pedometer - ergmeter
Short characteristics

Functions performed:

- 5 functions for counting time and calendar with indication of hours, minutes, seconds,
month, date ,
- count the quantity of steps by means of evaluation and counting pulses from external
sensor ;
- count and indication of steps, calories, kilometers , miles during current day and night
(mode DAILY STEPS COUNTER);
- summing up at changing 24 hours, steps , calories, kilometers , miles with values
stored previous ( mode TOTAL STEPS COUNTER).
Features:

- imbed in chip element of quartz generator with operating frequency of 32768 Hz,
capacity, resistor, and voltage doubler;
- operation from one battery with the voltage of 1.5V, low consumption power;
- availability of circuits of contacts bracing suppression on buttons inputs;
- frequency of registered pulses from external sensor at counting steps is no more than
6Hz at duration of time between the end of previous and beginning of counted pulse no
less than 100 ms;
- conversion of quantity of steps into calories , kilometres and miles according to the
following ratios:
(10 steps = 0.24 calorie
= 0.0073 klm
= 0.0045 mile ;
1000 steps = 24 calorie
= 0.73 klm
= 0.456 mile );
- indication of distance in miles and kilometers starting from 0.001, calories, starting
from 0.1.
Operating temperatures range
operating temperatures range from -0 to +70
.
IZ7007
2
able 1 - Limiting and extreme modes
Extreme mode
Limiting mode
Symbol in
letters
Name of parameter, mode , unit
of measurement
min
max
min
max
U
CC1
Primary supply voltage from the
source of voltage, V
1,2 1,8 -0,3 2,0
U
CC2
Secondary supply voltage, V
2U
CC1
-0,3 2U
CC1
-0,3 4,0
U
IH
Input voltage of high level, V
U
CC1
-0,3 U
CC1
-0,3
U
CC1
+0,3
U
IL
Input voltage of low level, V
Uss
Uss+0,3
-0,3
U
CC1
+0,3
ble 2 - Electric parameters
(mb = 25
)
Standard
Name of the parameter
in letters
min
max
mode of
measurement
unit of
measurement
Consumption current in primary supply
voltage chain from voltage source
I
CC1
- 0.6
U
CC1
=1.8 V
Consumption current in secondary supply
voltage chain
I
CC2
- 1.2
U
CC1
=1.8 V
dynamic consumption current
I
CCO
- 3.0
without load
U
CC1
=1.65 V
Input current of low level on
inputs S, M, D, COUNT
I
IL
- 5
U
CC1
=1.65 V
U
IL
=0.3 V
-
8
U
CC1
=1.8 V
U
IL
=0.3 V
Voltage of quartz generator start
U
OSC
- 1.45 t
5
V
voltage of quartz generator break-down
U
OSP
- 1.2
-
V










Figure1 - Format LCD
ble 3 - LCD segments State
F
G
A
B
E
D
C
P
AM
TODAY
TOTAL
ST
CALLS
KM
MILIS
1
2
3
4
5
6
COL
P3
P4
P5
P6
IZ7007
3
Segment COM1 COM2
Segment COM1 COM2
SEG28
AM PM
SEG14
P4
D4
SEG27 BC1 E2
SEG13 KM
E5
SEG26
ST
F2 SEG12
A5
F5
SEG25 A2 G2
SEG11 B5 G5
SEG24 B2 C2
SEG10 C5 D5
SEG23
COL
D2 SEG9
F6
P5
SEG22 F3 E3
SEG8 A6 E6
SEG21
CALLS
A3 SEG7
B6
G6
SEG20 B3 G3
SEG6 C6 D6
SEG19 C3 D3
SEG5 P6 TOTAL
SEG18 P3
TODAY
SEG4
MILIS
E7
SEG17 F4 E4
SEG3 A7 F7
SEG16 A4 G4
SEG2 B7 G7
SEG15 B4 C4
SEG1 C7 D7
Quartz resonator characteristics
Fp = 32768Hz
C
L
= 10pF
C
1
= 0.004pF
C
O
= 2.5pF
Rs = 35kOhm
Q = 35000
Figure 2 - application diagram
Iz7007
COM2
COM1
SEGMENTS
COUNT
OSCI
GND
.
Ucc
1
CAP1
CAP2
Quartz
resonator
C1: 0.1 F
C2: 0.1 F
1.5 V
+
-
LCD
Ucc2
IZ7007
4
Figure 3 -Control algorithm
*) The seconds will be reset to 00 and 1 will be added
to minutes if the current seconds is between 30 and 59
**) Current data reset with adding it to total data
***) Reset
CALENDAR
D
D
*)
PRESENT TIME
SET OF SECONDS
S
S
S
SET OF HOURS
SET OF MINUTES
S
SET OF MONTH
SET OF DATE
D
D
D
D
M
D
D
COUNT
QUANTITY OF STEPS
D
COUNT QUANTITY
OF CALORIES
COUNT DISTANCE
IN KILOMETERS
S
DATA OF CURRENT DAY
S
**)
M
D
D
D
D
S
***)
M
4
D
COUNT DISTANCE
IN MILES
TOTAL DATA
COUNT
QUANTITY OF STEPS
COUNT QUANTITY
OF CALORIES
COUNT DISTANCE
IN KILOMETERS
COUNT DISTANCE
IN MILES
IZ7007
5
Figure 4 - Control algorithm and display of date
*) The seconds will be reset to 00 and 1 will be added
to minutes if the current seconds is between 30 and 59
**) Current data reset with adding it to total data
***) Reset
D

*)
S
S
S1
S1
D
D
D
D
M
S
M
4
D
TOTAL DATA
D
DATA OF CURRENT DAY
S
**)
M
1 2 3 4 5 6 7
CALLS
TODAY
1 2 3 4 5 6 7
TODAY
D
1 2 3 4 5 6 7
TODAY
D
D
KM
MILIS
D
S
**)
1 2 3 4 5 6 7
ST
TOTAL
1 2 3 4 5 6 7
CALLS
1 2 3 4 5 6 7
D
1 2 3 4 5 6 7
D
D
KM
MILIS
TOTAL
TOTAL
TOTAL
1 2 3 4 5 6 7
1 2 3 4 5 6 7
ST
TODAY
1 2 3 4 5 6 7
AM
1 2 3 4 5 6 7
AM
1 2 3 4 5 6 7
AM
1 2 3 4 5 6 7
AM
S
1 2 3 4 5 6 7
1 2 3 4 5 6 7
S
D
S
D
D
D
D
.
COUNT
T > 166mc
t> 100mc
Figure 5 - Timing diagram