ChipFind - документация

Электронный компонент: 8GBU10

Скачать:  PDF   ZIP
8.0 Amps Single Phase Full Wave
Bridge Rectifier
I
O(AV)
= 8A
V
RRM
= 50/ 1200V
8GBU Series
1
Bulletin I2719 rev. F 11/02
www.irf.com
Features
Diode chips are glass passivated
Suitable for Universal hole mounting
Easy to assemble & install on P.C.B.
High Surge Current Capability
High Isolation between terminals and molded case (1500 V
RMS
)
Lead free terminals solderable as per MIL-STD-750 Method 2026
Terminals suitable for high temperature soldering at 260C for 8-10 secs
UL E160375 approved
Description
These GBU Series of Single Phase Bridges consist
of four glass passivated silicon junction connected
as a Full Wave Bridge. These four junctions are
encapsulated by plastic molding technique. These
Bridges are mainly used in Switch Mode power
supply and in industrial and consumer equipment.
Parameters
8GBU
Units
Major Ratings and Characteristics
I
O
8
A
@ T
C
100
C
I
FSM
@
50Hz
200
A
@ 60Hz
210
A
I
2
t
@ 50Hz
200
A
2
s
@ 60Hz
184
A
2
s
V
RRM
range
50 to 1200
V
T
J
- 55 to 150
o
C
8GBU
8GBU Series
2
Bulletin I2719 rev. F 11/02
www.irf.com
I
O
Maximum DC output current
8.0
A
T
C
= 100C, Resistive & inductive load
6.4
T
C
= 100C, Capacitive load
I
FSM
Maximum peak, one-cycle
200
t = 10ms
non-repetitive surge current,
following any rated load condition
210
t = 8.3ms
T
J
= 150C
and with rated V
RRM
reapplied
I
2
t
Maximum I
2
t for fusing,
200
A
2
s
t = 10ms
initial T
J
= T
J
max
184
t = 8.3ms
V
FM
Maximum peak forward voltage
1.0
V
T
J
= 25
o
C, I
FM
= 8A
per diode
I
RM
Typical peak reverse leakage
5.0
A
T
J
= 25
o
C, 100% V
RRM
curren t per diode
400
T
J
= 150
o
C, 100% V
RRM
V
RRM
Maximum repetitive peak
50 to 1200
V
reverse voltage range
Forward Conduction
Voltage V
RRM
, max repetitive V
RSM
, max non-repetitive V
RMS
, max RMS
I
RRM
max.
I
RRM
max.
Type number
Code
peak rev. voltage
peak rev. voltage
voltage
@ rated V
RRM
@ rated V
RRM
T
J
= T
J
max.
T
J
= T
J
max.
T
J
= T
J
max.
T
J
= 25C
T
J
= 150C
V
V
V
V
A
A
8GBU
005
50
80
35
5
400
01
100
150
70
5
400
02
200
300
140
5
400
04
400
500
280
5
400
06
600
725
420
5
400
08
800
900
560
5
400
10
1000
1100
700
5
400
12
1200
1300
850
5
400
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Parameters
8GBU
Unit
Conditions
Thermal and Mechanical Specifications
Note (1): Bridge mounted on Aluminun heat sink of dim 82x82x3.0mm, use silicon thermal compound heat
transfer and bolt down using 3mm screw
T
J
Operating and storage
-55 to 150
o
C
T
stg
temperature range
R
thJC
Max. thermal resistance
2.2
C/ W
DC rated current through bridge (1)
junction to case
R
thJA
Thermal resistance,
21
C/ W
DC rated current through bridge (1)
junction to ambient
W
Approximate weight
4 (0.14)
g (oz)
T
Mounting Torque
1.0
Nm
Bridge to Heatsink
9.0
Lb.in
Parameters
8GBU
Unit
Conditions
8GBU Series
3
Bulletin I2719 rev. F 11/02
www.irf.com
1
-
Bridge current
2
-
Basic Part Number
3
-
Voltage Code: code x 100 = V
RRM
8
GBU
12
1
2
3
Ordering Information Table
Device Code
Outline Table
All dimensions are in millimeters
8GBU Series
4
Bulletin I2719 rev. F 11/02
www.irf.com
Fig. 2 - Forward Voltage Drop Characteristics
Fig. 1 - Current Ratings Characteristics
Fig. 4 - Maximum Non-Repetitive Surge Current
Instantaneous Forward Voltage (V)
Instantaneous Forward Current (A)
Maximum Allowable Case Temperature (C)
Average Forward Current (A)
Number of Equal Amplitude Half Cycle Current Pulses (N)
Peak Half Sine Wave Forward Current (A)
Fig. 3 - Total Power Loss Characteristics
Maximum Average Forward Power Loss (W)
Average Forward Current (A)
90
100
110
120
130
140
150
160
0
1
2
3
4
5
6
7
8
9
180
(Sine)
180
(Rect)
8GBU Series
0.1
1
10
100
1000
0.5
1
1.5
2
2.5
3
3.5
T = 25C
J
T = 150C
J
8GBU Series
0
2
4
6
8
10
12
14
16
0
1
2
3
4
5
6
7
8
180
(Sine)
180
(Rect)
8GBU Series
T = 150C
J
60
80
100
120
140
160
180
200
220
1
10
100
At Any Rated Load Condition And With
Rated Vrrm Applied Following Surge.
Initial Tj = 150C
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
8GBU Series
8GBU Series
5
Bulletin I2719 rev. F 11/02
www.irf.com
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 11/02
Data and specifications subject to change without notice.
This product has been designed and qualified for Multiple Level.
Qualification Standards can be found on IR's Web site.