ChipFind - документация

Электронный компонент: IRKD600-12

Скачать:  PDF   ZIP
600 A
STANDARD DIODES
Bulletin I27402 rev. A 09/97
1
IRKD600.. SERIES
SUPER MAGN-A-pak
TM
Power Modules
www.irf.com
Major Ratings and Characteristics
Parameters
IRKD600..
Units
I
F(AV)
600
A
@ T
C
100
C
I
F(RMS)
942
A
@ T
C
100
C
I
FSM
@ 50Hz
19.0
KA
@ 60Hz
20.1
KA
I
2
t
@ 50Hz
1805
KA
2
s
@ 60Hz
1683
KA
2
s
I
2
t
18050
KA
2
s
V
RRM
range
800 to 2000
V
T
STG
range
- 40 to 150
C
T
J
range
- 40 to 150
C
Features
High current capability
3000 V
RMS
isolating voltage with non-toxic substrate
High surge capability
High voltage ratings up to 2000V
Industrial standard package
UL E78996 approved
Typical Applications
Rectifying bridge for large motor drives
Rectifying bridge for large UPS
IRKD600.. Series
2
Bulletin I27402 rev. A 09/97
www.irf.com
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Voltage
V
RRM
, maximum repetitive
V
RSM
, maximum non-
I
RRM
max.
Type number
Code
peak reverse voltage
repetitive peak rev. voltage
@ T
J
max.
V
V
mA
08
800
900
12
1200
1300
16
1600
1700
20
2000
2100
IRKD600..
50
I
F(AV)
Maximum average forward current
600
A
180 conduction, half sine wave
@ Case temperature
100
C
I
F(RMS)
Maximum RMS forward current
942
A
180 conduction, half sine wave @ T
C
= 100C
I
FSM
Maximum peak, one-cycle forward,
19.0
KA
t = 10ms
No voltage
non-repetitive surge current
20.1
t = 8.3ms
reapplied
16.2
t = 10ms
100% V
RRM
17.2
t = 8.3ms
reapplied
Sinusoidal half wave,
I
2
t
Maximum I
2
t for fusing
1805
KA
2
s
t = 10ms
No voltage
Initial T
J
= T
J
max.
1683
t = 8.3ms
reapplied
1319
t = 10ms
100% V
RRM
1230
t = 8.3ms
reapplied
I
2
t
Maximum I
2
t for fusing
18050
KA
2
s t = 0.1 to 10ms, no voltage reapplied
V
F(TO)1
Low level value of threshold voltage
0.70
V
(16.7% x
x I
F(AV)
< I <
x I
F(AV)
), T
J
= T
J
max.
V
F(TO)2
High level value of threshold voltage
0.77
(I >
x I
F(AV)
), T
J
= T
J
max.
r
f1
Low level value of forward slope resistance
0.28
m
(16.7% x
x I
F(AV)
< I <
x I
F(AV)
), T
J
= T
J
max.
r
f2
High level value of forward slope resistance
0.25
(I >
x I
F(AV)
), T
J
= T
J
max.
V
FM
Maximum forward voltage drop
1.24
V
I
pk
= 1800A, T
J
= 25C, t
p
= 10ms sine pulse
Parameter
IRKD600..
Units Conditions
Forward Conduction
V
INS
RMS isolation voltage
3000
V
t = 1 s
I
RRM
Maximum peak reverse and off-state
50
mA
T
J
= T
J
max., rated V
RRM
applied
leakage current
Parameter
IRKD600..
Units Conditions
Blocking
IRKD600.. Series
3
Bulletin I27402 rev. A 09/97
www.irf.com
Parameter
IRKD600..
Units Conditions
Thermal and Mechanical Specifications
T
J
Max. junction operating temperature range
- 40 to 150
C
T
stg
Max. storage temperature range
- 40 to 150
R
thJC
Max. thermal resistance, junction to
0.065
K/W
Per junction, DC operation
case
R
thC-hs
Max. thermal resistance, case to
0.02
K/W
heatsink
T
Mounting torque 10%SMAP to heatsink
6 - 8
Nm
busbar to SMAP
12 - 15
wt
Approximate weight
1500
g
Case style
SUPER MAGN-A-pak
See outline table
IRK
D
600
-
20
1
2
3
1
-
Module type
2
-
Circuit configuration D = 2 diodes in series
3
-
Current rating
4
-
Voltage code: Code x 100 = V
RRM
(See Voltage Ratings Table)
4
Device Code
Ordering Information Table
R
thJC
Conduction
(The following table shows the increment of thermal resistance R
thJC
when devices operate at different conduction angles than DC)
Conduction angle
Sinusoidal conduction Rectangular conduction
Units
Conditions
180
0.009
0.006
120
0.011
0.011
90
0.014
0.015
K/W
T
J
= T
J
max.
60
0.021
0.022
30
0.037
0.038
+
-
~
1
2
3
A mounting compound is recommended and the
torque should be rechecked after a period of 3 hours
to allow for the spread of the compound
IRKD600.. Series
4
Bulletin I27402 rev. A 09/97
www.irf.com
Outline Table
All dimensions in millimeters (inches)
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Current Ratings Characteristics
80
90
100
110
120
130
140
150
0
100
200
300
400
500
600
700
30
60
90
120
180
M
a
x
i
m
u
m

A
l
low
a
b
l
e
C
a
s
e
Te
m
p
e
r
a
t
u
r
e (
C
)
Conduction Angle
Average Forward Current (A)
IRKD600.. Series
R (DC) = 0.065 K/W
thJC
80
90
100
110
120
130
140
150
0
200
400
600
800
1000
DC
30
60
90
120
180
M
a
x
i
m
u
m
A
l
l
o
wabl
e

C
a
se
T
e
m
pe
r
a
t
u
r
e

(
C
)
Conduction Period
Average Forward Current (A)
IRKD600.. Series
R (DC) = 0.065 K/W
thJC
IRKD600.. Series
5
Bulletin I27402 rev. A 09/97
www.irf.com
Fig. 4 - Forward Power Loss Characteristics
Fig. 3 - Forward Power Loss Characteristics
Fig. 5 - Maximum Non-Repetitive Surge Current
Fig. 6 - Maximum Non-Repetitive Surge Current
Fig. 7 - Forward Power Loss Characteristics
0
100
200
300
400
500
600
700
0
100
200
300
400
500
600
Average Forward Current (A)
RMS Limit
M
a
x
i
m
u
m
A
v
e
r
ag
e
F
o
r
w
ar
d P
o
w
e
r
Lo
ss
(
W
)
Conduction Angle
180
120
90
60
30
IRKD600.. Series
Per Junction
T = 150C
J
0
100
200
300
400
500
600
700
800
900
1000
0
200
400
600
800
1000
DC
180
120
90
60
30
Average Forward Current (A)
RMS Limit
M
a
x
i
m
u
m
A
v
e
r
ag
e
F
o
r
w
a
r
d
P
o
we
r
Lo
ss
(
W
)
Conduction Period
IRKD600.. Series
Per Junction
T = 150C
J
4000
6000
8000
10000
12000
14000
16000
18000
1
10
100
P
e
ak
Hal
f
S
i
ne
W
a
v
e

F
o
r
war
d C
u
r
r
e
nt

(
A
)
Number Of Equal Amplitude Half Cycle Curre nt Pulses (N)
IRKD600.. Series
Per Junction
Initial T = 150C
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
At Any Rated Load Condition And With
Rated V Applied Following Surge.
RRM
J
0
25
50
75
100
125
150
Maximum Allowable Ambient Temperature (C)
R
=
0
.0
2
K
/W
- D
e
lta
R
th
S
A
0
.0
4 K
/W
0.
0
6
K
/W
0.0
8 K
/W
0.1
2 K
/W
0.1
6 K
/W
0.25
K/W
0.35
K/W
0.5 K/W
0
200
400
600
800
1000
0
200
400
600
800
1000
Total RMS Output Current (A)
M
a
x
i
m
u
m
T
o
t
a
l
F
o
r
war
d P
o
we
r
Lo
ss
(
W
)
IRKD600.. Series
Per Junction
T = 150C
J
180
(Sine)
DC
4000
6000
8000
10000
12000
14000
16000
18000
20000
0.01
0.1
1
P
e
ak

Hal
f S
i
ne

W
a
v
e
F
o
r
war
d C
u
r
r
e
n
t
(
A
)
Pulse Train Duration (s)
Maximum Non Repetitive Surge Current
Initial T = 150C
No Voltage Reapplied
Rated V Reapplied
RRM
Versus Pulse Train Dura tion.
J
IRKD600.. Series
Per Junction