Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
1
R e v . C
04/16/03
IS42S16400A
ISSI
Copyright 2003 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make changes to this specification and its products at any time without notice. ISSI assumes no
liability arising out of the application or use of any information, products or services described herein. Customers are advised to obtain the latest version of this device specification before relying on
any published information and before placing orders for products.
FEATURES
Clock frequency:166, 133, 100 MHz
Fully synchronous; all signals referenced to a
positive clock edge
Internal bank for hiding row access/precharge
Single 3.3V power supply
LVTTL interface
Programmable burst length
(1, 2, 4, 8, full page)
Programmable burst sequence:
Sequential/Interleave
Self refresh modes
4096 refresh cycles every 64 ms
Random column address every clock cycle
Programmable
CAS
latency (2, 3 clocks)
Burst read/write and burst read/single write
operations capability
Burst termination by burst stop and precharge
command
Byte controlled by LDQM and UDQM
Industrial temperature availability
(133MHz, 100MHz)
Package: 400-mil 54-pin TSOP II,
a lead-free package is available.
OVERVIEW
ISSI
's 64Mb Synchronous DRAM IS42S16400A is organized
as 1,048,576 bits x 16-bit x 4-bank for improved
performance. The synchronous DRAMs achieve high-speed
data transfer using pipeline architecture. All inputs and
outputs signals refer to the rising edge of the clock input.
1 Meg Bits x 16 Bits x 4 Banks (64-MBIT)
SYNCHRONOUS DYNAMIC RAM
April 2003
PIN CONFIGURATIONS
54-Pin TSOP (Type II)
VCC
I/O0
VCCQ
I/O1
I/O2
GNDQ
I/O3
I/O4
VCCQ
I/O5
I/O6
GNDQ
I/O7
VCC
LDQM
WE
CAS
RAS
CS
BA0
BA1
A10
A0
A1
A2
A3
VCC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
GND
I/O15
GNDQ
I/O14
I/O13
VCCQ
I/O12
I/O11
GNDQ
I/O10
I/O9
VCCQ
I/O8
GND
NC
UDQM
CLK
CKE
NC
A11
A9
A8
A7
A6
A5
A4
GND
PIN DESCRIPTIONS
A0-A11
Address Input
BA0, BA1
Bank Select Address
I/O0 to I/O15
Data I/O
CLK
System Clock Input
CKE
Clock Enable
CS
Chip Select
RAS
Row Address Strobe Command
CAS
Column Address Strobe Command
WE
Write Enable
LDQM
Lower Bye, Input/Output Mask
UDQM
Upper Bye, Input/Output Mask
Vcc
Power
GND
Ground
Vcc
Q
Power Supply for I/O Pin
GND
Q
Ground for I/O Pin
NC
No Connection
IS42S16400A
ISSI
2
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
R e v . C
04/16/03
GENERAL DESCRIPTION
The 64Mb SDRAM is a high speed CMOS, dynamic
random-access memory designed to operate in 3.3V
memory systems containing 67,108,864 bits. Internally
configured as a quad-bank DRAM with a synchronous
interface. Each 16,777,216-bit bank is organized as 4,096
rows by 256 columns by 16 bits.
The 64Mb SDRAM includes an AUTO REFRESH MODE,
and a power-saving, power-down mode. All signals are
registered on the positive edge of the clock signal, CLK.
All inputs and outputs are LVTTL compatible.
The 64Mb SDRAM has the ability to synchronously burst
data at a high data rate with automatic column-address
generation, the ability to interleave between internal banks
to hide precharge time and the capability to randomly
change column addresses on each clock cycle during
burst access.
A self-timed row precharge initiated at the end of the burst
sequence is available with the AUTO PRECHARGE
function enabled. Precharge one bank while accessing one
of the other three banks will hide the precharge cycles and
provide seamless, high-speed, random-access operation.
SDRAM read and write accesses are burst oriented starting
at a selected location and continuing for a programmed
number of locations in a programmed sequence. The
registration of an ACTIVE command begins accesses,
followed by a READ or WRITE command. The ACTIVE
command in conjunction with address bits registered are
used to select the bank and row to be accessed (BA0, BA1
select the bank; A0-A11 select the row). The READ or
WRITE commands in conjunction with address bits reg-
istered are used to select the starting column location for
the burst access.
Programmable READ or WRITE burst lengths consist of
1, 2, 4 and 8 locations or full page, with a burst terminate
option.
CLK
CKE
CS
RAS
CAS
WE
A11
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
BA0
BA1
A10
COMMAND
DECODER
&
CLOCK
GENERATOR
MODE
REGISTER
REFRESH
CONTROLLER
REFRESH
COUNTER
SELF
REFRESH
CONTROLLER
ROW
ADDRESS
LATCH
MUL
TIPLEXER
COLUMN
ADDRESS LATCH
BURST COUNTER
COLUMN
ADDRESS BUFFER
COLUMN DECODER
DATA IN
BUFFER
DATA OUT
BUFFER
DQM
I/O 0-15
Vcc/Vcc
Q
GND/GNDQ
11
11
8
11
11
8
16
16
16
16
256K
(x 16)
4096
4096
4096
R
O
W DECODER
4096
MEMORY CELL
ARRAY
BANK 0
SENSE AMP I/O GATE
BANK CONTROL LOGIC
ROW
ADDRESS
BUFFER
FUNCTIONAL BLOCK DIAGRAM
IS42S16400A
ISSI
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
3
R e v . C
04/16/03
PIN FUNCTIONS
Symbol
Pin No.
Type
Function (In Detail)
A0-A11
23 to 26
Input Pin
Address Inputs: A0-A11 are sampled during the ACTIVE
29 to 34
command (row-address A0-A11) and READ/WRITE command (A0-A7
22, 35
with A10 defining auto precharge) to select one location out of the memory array
in the respective bank. A10 is sampled during a PRECHARGE command to
determine if all banks are to be precharged (A10 HIGH) or bank selected by
BA0, BA1 (LOW). The address inputs also provide the op-code during a LOAD
MODE REGISTER command.
BA0, BA1
20, 21
Input Pin
Bank Select Address: BA0 and BA1 defines which bank the ACTIVE, READ,
WRITE or PRECHARGE command is being applied.
CAS
17
Input Pin
CAS
, in conjunction with the
RAS
and
WE
, forms the device command. See the
"Command Truth Table" for details on device commands.
CKE
37
Input Pin
The CKE input determines whether the CLK input is enabled. The next rising edge
of the CLK signal will be valid when is CKE HIGH and invalid when LOW. When
CKE is LOW, the device will be in either power-down mode, clock suspend mode,
or self refresh mode. CKE is an asynchronous input.
CLK
38
Input Pin
CLK is the master clock input for this device. Except for CKE, all inputs to this
device are acquired in synchronization with the rising edge of this pin.
CS
19
Input Pin
The
CS
input determines whether command input is enabled within the device.
Command input is enabled when
CS
is LOW, and disabled with
CS
is HIGH. The
device remains in the previous state when
CS
is HIGH.
I/O0 to
2, 4, 5, 7, 8, 10,
I/O Pin
I/O0 to I/O15 are I/O pins. I/O through these pins can be controlled in byte units
I/O15
11,13, 42, 44, 45,
using the LDQM and UDQM pins.
47, 48, 50, 51, 53
LDQM,
15, 39
Input Pin
LDQM and UDQM control the lower and upper bytes of the I/O buffers. In read
UDQM
mode, LDQM and UDQM control the output buffer. When LDQM or UDQM is
LOW, the corresponding buffer byte is enabled, and when HIGH, disabled. The
outputs go to the HIGH impedance state when LDQM/UDQM is HIGH. This
function corresponds to
OE
in conventional DRAMs. In write mode, LDQM and
UDQM control the input buffer. When LDQM or UDQM is LOW, the corresponding
buffer byte is enabled, and data can be written to the device. When LDQM or
UDQM is HIGH, input data is masked and cannot be written to the device.
RAS
18
Input Pin
RAS
, in conjunction with
CAS
and
WE
, forms the device command. See the
"Command Truth Table" item for details on device commands.
WE
16
Input Pin
WE
, in conjunction with
RAS
and
CAS
, forms the device command. See the
"Command Truth Table" item for details on device commands.
V
CCQ
3, 9, 43, 49
Power Supply Pin
V
CCQ
is the output buffer power supply.
V
CC
1, 14, 27
Power Supply Pin
V
CC
is the device internal power supply.
GND
Q
6, 12, 46, 52
Power Supply Pin
GND
Q
is the output buffer ground.
GND
28, 41, 54
Power Supply Pin
GND is the device internal ground.
IS42S16400A
ISSI
4
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
R e v . C
04/16/03
FUNCTION (In Detail)
A0-A11 are address inputs sampled during the ACTIVE
(row-address A0-A11) and READ/WRITE command (A0-A7
with A10 defining auto PRECHARGE). A10 is sampled during
a PRECHARGE command to determine if all banks are to
be PRECHARGED (A10 HIGH) or bank selected by BA0,
BA1 (LOW). The address inputs also provide the op-code
during a LOAD MODE REGISTER command.
Bank Select Address (BA0 and BA1) defines which bank the
ACTIVE, READ, WRITE or PRECHARGE command is
being applied.
CAS
, in conjunction with the
RAS
and
WE
, forms the
device command. See the "Command Truth Table" for
details on device commands.
The CKE input determines whether the CLK input is
enabled. The next rising edge of the CLK signal will be
valid when is CKE HIGH and invalid when LOW. When
CKE is LOW, the device will be in either power-down
mode, CLOCK SUSPEND mode, or SELF-REFRESH
mode. CKE is an asynchronous input.
CLK is the master clock input for this device. Except for
CKE, all inputs to this device are acquired in synchroni-
zation with the rising edge of this pin.
The
CS
input determines whether command input is
enabled within the device. Command input is enabled
when
CS
is LOW, and disabled with
CS
is HIGH. The
device remains in the previous state when
CS
is HIGH. I/
O0 to I/O15 are I/O pins. I/O through these pins can be
controlled in byte units using the LDQM and UDQM pins.
LDQM and UDQM control the lower and upper bytes of the
I/O buffers. In read mode, LDQM and UDQM control the
output buffer. When LDQM or UDQM is LOW, the corre-
sponding buffer byte is enabled, and when HIGH, dis-
abled. The outputs go to the HIGH Impedance State when
LDQM/UDQM is HIGH. This function corresponds to
OE
in conventional DRAMs. In write mode, LDQM and UDQM
control the input buffer. When LDQM or UDQM is LOW,
the corresponding buffer byte is enabled, and data can be
written to the device. When LDQM or UDQM is HIGH,
input data is masked and cannot be written to the device.
RAS
, in conjunction with
CAS
and
WE
, forms the device
command. See the "Command Truth Table" item for
details on device commands.
WE
, in conjunction with
RAS
and
CAS
, forms the device
command. See the "Command Truth Table" item for
details on device commands.
V
CCQ
is the output buffer power supply.
V
CC
is the device internal power supply.
GND
Q
is the output buffer ground.
GND is the device internal ground.
READ
The READ command selects the bank from BA0, BA1
inputs and starts a burst read access to an active row.
Inputs A0-A7 provides the starting column location. When
A10 is HIGH, this command functions as an AUTO
PRECHARGE command. When the auto precharge is
selected, the row being accessed will be precharged at
the end of the READ burst. The row will remain open for
subsequent accesses when AUTO PRECHARGE is not
selected. DQ's read data is subject to the logic level on
the DQM inputs two clocks earlier. When a given DQM
signal was registered HIGH, the corresponding DQ's will
be High-Z two clocks later. DQ's will provide valid data
when the DQM signal was registered LOW.
WRITE
A burst write access to an active row is initiated with the
WRITE command. BA0, BA1 inputs selects the bank, and
the starting column location is provided by inputs A0-A7.
Whether or not AUTO-PRECHARGE is used is deter-
mined by A10.
The row being accessed will be precharged at the end of
the WRITE burst, if AUTO PRECHARGE is selected. If
AUTO PRECHARGE is not selected, the row will remain
open for subsequent accesses.
A memory array is written with corresponding input data
on DQ's and DQM input logic level appearing at the same
time. Data will be written to memory when DQM signal is
LOW. When DQM is HIGH, the corresponding data inputs
will be ignored, and a WRITE will not be executed to that
byte/column location.
PRECHARGE
The PRECHARGE command is used to deactivate the
open row in a particular bank or the open row in all banks.
BA0, BA1 can be used to select which bank is precharged
or they are treated as "Don't Care". A10 determined
whether one or all banks are precharged. After executing
this command, the next command for the selected banks(s)
is executed after passage of the period t
RP
, which is the
period required for bank precharging. Once a bank has
been precharged, it is in the idle state and must be
activated prior to any READ or WRITE commands being
issued to that bank.
AUTO PRECHARGE
The AUTO PRECHARGE function ensures that the
precharge is initiated at the earliest valid stage within a
burst. This function allows for individual-bank precharge
without requiring an explicit command. A10 to enables the
AUTO PRECHARGE function in conjunction with a spe-
cific READ or WRITE command. For each individual
READ or WRITE command, auto precharge is either
IS42S16400A
ISSI
Integrated Silicon Solution, Inc. -- www.issi.com --
1-800-379-4774
5
R e v . C
04/16/03
enabled or disabled. AUTO PRECHARGE does not apply
except in full-page burst mode. Upon completion of the
READ or WRITE burst, a precharge of the bank/row that
is addressed is automatically performed.
AUTO REFRESH COMMAND
This command executes the AUTO REFRESH operation.
The row address and bank to be refreshed are automatically
generated during this operation. The stipulated period (t
RC
)
is required for a single refresh operation, and no other
commands can be executed during this period. This com-
mand is executed at least 4096 times every 64ms. During
an AUTO REFRESH command, address bits are "Don't
Care". This command corresponds to CBR Auto-refresh.
SELF REFRESH
During the SELF REFRESH operation, the row address to
be refreshed, the bank, and the refresh interval are
generated automatically internally. SELF REFRESH can
be used to retain data in the SDRAM without external
clocking, even if the rest of the system is powered down.
The SELF REFRESH operation is started by dropping the
CKE pin from HIGH to LOW. During the SELF REFRESH
operation all other inputs to the SDRAM become "Don't
Care".The device must remain in self refresh mode for a
minimum period equal to t
RAS
or may remain in self refresh
mode for an indefinite period beyond that.The SELF-
REFRESH operation continues as long as the CKE pin
remains LOW and there is no need for external control of
any other pins.The next command cannot be executed
until the device internal recovery period (t
RC
) has elapsed.
Once CKE goes HIGH, the NOP command must be
issued (minimum of two clocks) to provide time for the
completion of any internal refresh in progress. After the
self-refresh, since it is impossible to determine the ad-
dress of the last row to be refreshed, an AUTO-REFRESH
should immediately be performed for all addresses.
BURST TERMINATE
The BURST TERMINATE command forcibly terminates
the burst read and write operations by truncating either
fixed-length or full-page bursts and the most recently
registered READ or WRITE command prior to the BURST
TERMINATE.
COMMAND INHIBIT
COMMAND INHIBIT prevents new commands from being
executed. Operations in progress are not affected, apart
from whether the CLK signal is enabled
NO OPERATION
When
CS
is low, the NOP command prevents unwanted
commands from being registered during idle or wait
states.
LOAD MODE REGISTER
During the LOAD MODE REGSITER command the mode
register is loaded from A0-A11. This command can only
be issued when all banks are idle.
ACTIVE COMMAND
When the ACTIVE COMMAND is activated, BA0, BA1
inputs selects a bank to be accessed, and the address
inputs on A0-A11 selects the row. Until a PRECHARGE
command is issued to the bank, the row remains open for
accesses.