ChipFind - документация

Электронный компонент: 157.5700.5351

Скачать:  PDF   ZIP
Mae in mm / Dimensions in mm / Dimensions en mm
Schmelzzeit-Grenzwerte / Pre-arcing time - limits / Temps de fusion limits
Normen / Specifications / Normes
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership,we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
WebSite
www.littelfuse.com
157.5700.5351
157.5700.5401*
157.5700.5501
157.5700.5631
157.5700.5801
157.5700.6101
157.5700.6121
157.5700.6131*
157.5700.6141*
157.5700.6151*
157.5700.6161
157.5700.6171*
157.5700.6201
157.5700.6231*
157.5700.6251
157.5700.6271*
157.5700.6301
157.5700.6331*
157.5700.6351
157.5700.6401*
157.5700.6421
157.5700.6501*
35 A
40 A
50 A
63 A
80 A
100 A
125 A
130 A
135 A
150 A
160 A
175 A
200 A
225 A
250 A
275 A
300 A
325 A
355 A
400 A
425 A
500 A
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
125 mV
157.5916.5351*
157.5916.5501*
157.5916.5631*
157.5916.5801*
157.5916.6101*
157.5916.6121*
157.5916.6131 *
157.5916.6141*
157.5916.6151*
157.5916.6161*
157.5916.6171*
157.5916.6201*
157.5916.6251*
a = 11 mm
a = 9 mm*
Artikel-Nr.
Article-No.
Rf. d'article
Spannungsfall
Voltage drop
Chute de tension
U
D
Nennstrom
Rated current
Intensit nom.
I
N
/I
rat
PUDENZ
max.
* in der Normreihe nicht verzeichnet / not mentioned in the standards / pas mentionn dans la norme
zugehriger Halter siehe Seite 52-53 / corresponding holder see page 52-53 / porte-fusible correspondant voir page 52-53
Sicherungsstreifen
Sicherungsstreifen
Sicherungsstreifen
Sicherungsstreifen
Sicherungsstreifen
fr Flurfrderzeuge fr Nennspannungen bis 80 V /
Fuse strips
Fuse strips
Fuse strips
Fuse strips
Fuse strips
for batterie-powered vehicles for rated voltage up to 80 V /
Fusibles-lames
Fusibles-lames
Fusibles-lames
Fusibles-lames
Fusibles-lames
pour vhicules batterie pour tension nom. jusqu' 80 V
Metallteile / Metal parts / Pices mtalliques:
35 A - 80 A:
Zn-Legierung / Zinc-alloy / Zinc-alliage
100A - 425 A:
Kupfer Cu, gal. Sn / Copper Cu, gal. Sn / Cuivre Cu, gal. Sn
Verpackungseinheit / Packaging unit / Emballage:
50 Stck / pieces / pices
min.
max.
1,50 I
N
/ I
rat
2,20 I
N
/ I
rat
4,00 I
N
/ I
rat
35 A - 200 A
225 A - 425 A
35 A - 200 A
225 A - 425 A
35 A - 200 A
225 A - 425 A
35 A - 200 A
225 A - 425 A
1 h
60 s (1,6In)
-
-
-
-
800 ms
-
250 ms
250 ms
60 s
60 s
10 s
10 s
2 s
2 s
2,50 I
N
/ I
rat
DIN
43560/1
F
I
= 1,00 (max. Dauerstrom / max. operating current / max. courant permanent: 1,0 x I
rat
bei / at / 23C)