ChipFind - документация

Электронный компонент: SL1003A300

Скачать:  PDF   ZIP
Gas Discharge Tubes
331
w w w . l i t t e l f u s e . c o m
3 ELECTRODE GDT
GRAPHICAL SYMBOL
1003
Voltage
Type
3 Pole Arrester
A XXX
Pin Configuratio
C= Core
R= Leaded
n
SL
ORDERING INFORMATION
All dimensions in mm
GreentubeTM SL1003 Series Gas Plasma Arresters
High Performance Beta Range
The SL1003 series has been especially developed for Broadband
equipment. Unique design features offer high levels of perform-
ance on fast rising transients in the domain of 100V/
S to
1KV/
S, which are those most likely from induced Lightning dis-
turbances. These devices have Ultra low capacitance ( typically
1.2pF or less ) and present insignificant signal losses up to
1.5GHz. These devices are extremely robust and are able to
divert a 5000A pulse without destruction. For AC Power Cross of
long duration, overcurrent protection is recommended.
FEATURES
RoHS
compliant
Low insertion loss
Surface mountable
5KA surge capability tested with 8/20
S pulse as defined by
IEC 61000-4-5
GHz working frequency.
Excellent response to fast rising transients.
Can be used to meet Telcordia GR1089 without
series resistance
10/700 6KV capability, as per ITUT k.21, enhanced test level
2000 Amp 2/10
S surge rating
Applications:
Broadband equipment.
ADSL equipment.
XDSL equipment.
Satellite and CATV equipment.
General telecom equipment.
Pb
RoHS
Gas Discharge Tubes
332
w w w . l i t t e l f u s e . c o m
8
G
A
S
D
I
S
C
H
A
R
G
E
T
U
B
E
S
Nominal
On-State
Voltage @
1A (V)
20
20
20
20
20
20
20
20
LITTELFUSE 3 TERMINAL MINI ARRESTER SERIES
TOTALLY NON-RADIOACTIVE, UL RECOGNIZED
Notes:
(1) Tested according to ITU-T Rec.K12
(2) 10 shots, 8/20s wave form per IEC 61000-4-5
(3) Measured @ 100 Volts
(4) Measured @ 1 MHz, 0 volt bias
(5) Measured with 2/10s wave form
(6) Measured with 10/350s wave form
(7) Measured @ 100VDC except 90V which is measured at 50VDC
Part Number
SL1003A090
SL1003A230
SL1003A250
SL1003A260
SL1003A300
SL1003A350
SL1003A400
SL1003A450
DC Voltage
@100V/sec
(V)
90
230
250
260
300
350
400
450
Max Dynamic
Breakover
Voltage @
100 V/s (Vbr)
600
350
400
420
450
500
550
650
Max Dynamic
Breakover
Voltage @
1 kV/s (Vbr)
700
500
600
600
650
700
800
800
Max Repetitive
Impulse
Discharge
Current
2
(kA)
5
5
5
5
5
5
5
5
Insulation
Resistance
7
(
)
1x10
9
@50V
1x10
9
@100V
1x10
9
@100V
1x10
9
@100V
1x10
9
@100V
1x10
9
@100V
1x10
9
@100V
1x10
9
@100V
Max
Capacitance
4
(pF)
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
Holdover
Voltage
1
(V)
50
135
135
135
135
135
135
135
GreentubeTM SL1003 Series Gas Plasma Arresters
High Performance Beta Range
Alternating
Discharge
Current
3
(A)
5
5
5
5
5
5
5
5
V
o
l
t
a
g
e
(
V
)
Time (ns)
0
200 400 600 800 1000
1200
Max dynamic breakover
voltage
Hold-over voltage
On-State voltage
Voltage vs Time Characteristic
Typical Inser
tion loss figures
@1.0 GHz = 0.01dB
@1.4 GHz = 0.1dB
@1.8 GHz = 0.53dB
@2.1 GHz = 0.81dB
@2.45 GHz = 1.0dB
@2.8 GHz = 1.2dB
@3.1 GHz= 1.5dB
@3.5 GHz = 2.1dB
Pb
RoHS
Gas Discharge Tubes
High Performance Beta Range
333
w w w . l i t t e l f u s e . c o m
GreentubeTM SL1003 Series Gas Plasma Arresters
Pb
RoHS
Solder
T
1
max = 266
o
C
Flow Area
T
1
= 239
o
C
200
300
Tm = 179
o
C
Forced Cooling
Preheating
Area
100
10
20
30
40
Time (seconds)
T
e
m
p
e
r
a
t
u
r
e
(

C
)
Profile for wave soldering
Notes:
T
1
max
= Maximum Tab Temperature = 266
o
C
T
1
= Flow Tempearture of Solder = 239
o
C
Tm
= Melting Point of Solder = 179
o
C
Tamb
= 25
o
C
Maximum permissible rate of temperature change = 7
o
C / sec
0
0
2 5
5 0
7 5
100
125
150
175
200
225
250
50
100
150
200
250
300
350
400
450
500
Time in seconds
T
e
m
p
e
r
a
t
u
r
e

C
Profile for reflow soldering