ChipFind - документация

Электронный компонент: DR754

Скачать:  PDF   ZIP
DR750
THRU
DR7510
Passivated Rectifier
50 - 1000 Volts
R-6
Features
Low Cost
High Current Capability
High Surge Current Capability
Low Leakage
DIMENSIONS
INCHES
MM
DIM
MIN
MAX
MIN
MAX
NOTE
A
.340
.360
8.60
9.10
B
.340
.360
8.60
9.10
C
.048
.052
1.20
1.30
D
1.000
---
25.40
---
Maximum Ratings
Operating Temperature: -50
C to +150
C
Storage Temperature: -50
C to +150
C
Maximum Thermal Resistance; 10
C/W Junction To Ambient
MCC
Catalog
Number
Device
Marking
Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
DR750 --- 50V 35V 50V
DR751 --- 100V 70V 100V
DR752 --- 200V 140V 200V
DR754 --- 400V 280V 400V
DR756 --- 600V 420V 600V
DR758 --- 800V 560V 800V
DR7510 --- 1000V 700V 1000V
Electrical Characteristics @ 25
C Unless Otherwise Specified
Average Forward
Current
I
F(AV)
6.0A
T
A
= 60
C
Peak Forward Surge
Current
I
FSM
200A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
V
F
1.1V I
FM
= 6.0A;
T
J
= 25
C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
R
10
A
1mA
T
J
= 25
C
T
J
= 100
C
Typical Junction
Capacitance
C
J
100pF Measured at
1.0MHz, V
R
=4.0V
*Pulse test: Pulse width 300
sec, Duty cycle 1%
A
B
D
D
C
Cathode
Mark
www.
mccsemi
.com
6 Amp Glass
omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
M C C
DR750 thru DR7510
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
C
Figure 2
Forward Derating Curve
0
175
50
75
100
125
0
1
2
3
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
C
150
4
5
6
Thermal Resistance -
C/W
versus
Equal Lead Length To Heat Sink - Inches
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
40
60
200
100
Amps
.6
.8
1.0
1.2
1.4
1.6
.1
.2
.4
.6
1
2
4
6
10
20
25
C
Volts
Figure 3
Typical Thermal Resistance versus Lead Length
.1
.2
.3
.5
.6
.7
.4
.8
.9
0
10
20
C/W
Inches
15
5
1.0
1.1
PC BOARD
PC BOARD
www.
mccsemi
.com
M C C
1
100
4
0
50
5
100
150
8
Figure 5
Maximum Non-Repetitive Forward Surge Current
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20
60 80
40
200
250
300
Figure 4
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Volts
4
6
20
10
Amps
20
120
40
60
80
100
.01
.02
.04
.06
.1
.2
.4
.6
1
2
T
J
=25
C
40
60
100
140
T
J
=100
C
www.
mccsemi
.com
M C C
DR750 thru DR7510