KBPC3500S
THRU
KBPC3510S
35 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
Features
Maximum Ratings
Operating Temperature: -55
C to +150
C
Storage Temperature: -55
C to +150
C
MCC
Catalog
Number
Device
Marking
Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
KBPC3500S KBPC3500S
50V 35V 50V
KBPC3501S KBPC3501S
100V 70V 100V
KBPC3502S KBPC3502S
200V 140V 200V
KBPC3504S KBPC3504S

400V 280V 400V
KBPC3506S KBPC3506S
600V 420V 600V
KBPC3508S KBPC350 8S
800V 560V 800V
KBPC3510S KBPC3510S
1000V 700V 1000V
Electrical Characteristics @ 25
C Unless Otherwise Specified
Average Forward
Current
I
F(AV)
35.0A T
C
=
60
C
Peak Forward Surge
Current
I
FSM
400A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element
V
F
1.2V I
FM
= 17.5A per
element;
T
A
= 25
C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
R
10
A
1.0mA
T
A
= 25
C
T
A
= 100
C
*Pulse test: Pulse width 300
sec, Duty cycle 1%
KBPC
Ideal for Printed Circuit Boards
Designed for Saving Mounting Space
Low Forward Voltage Drop
High Current Capability
High Reliability
High Surge Current Capability
www.
mccsemi
.com
INCHES
MM
DIM
MIN
MAX
MIN
MAX
NOTE
A 1.12 1.13 28.40 28.70
B .432 .442 10.97 11.23
C .547 --- 13.90 ---
D .752 --- 19.10 ---
E .201 --- 5.10 ---
G .047 --- 1.20 ---
H .120 .142 3.05 3.60
DIMENSIONS
omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
M C C
KBPC3500S thru KBPC3510S
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes
versus
Case Temperature -
C
Figure 3
Forward Derating Curve
25
50
100
150
175
0
0
10
20
30
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
C
75
40
50
60
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.2
1.2
.4
.6
.8
1.0
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25
C
40
60
100
1.4
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
Amps
20
120
40
60
80
100
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
140
T
A
=25
C
1
100
4
0
100
200
300
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10
20
60 80
40
00
400
500
600
M C C
www.
mccsemi
.com