ChipFind - документация

Электронный компонент: RL203

Скачать:  PDF   ZIP
RL201
THRU
RL207
2 Amp
Silicon Rectifier
50 to 1000 Volts
Features
Low Cost
Low Leakage
Low Forward Voltage Drop
High Current Capability
DIMENSIONS
INCHES
MM
DIM
MIN
MAX
MIN
MAX
NOTE
A
.230
.300
5.80
7.60
B
.104
.140
2.60
3.60
C
.026
.034
.70
.90
D
1.000
---
25.40
---
Maximum Ratings
Operating Temperature: -55
C to +150
C
Storage Temperature: -55
C to +150
C
Typical Thermal Resistance (R
JA
) 40
C/W
MCC
Catalog
Number
Device
Marking
Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
RL201
---
50V
35V
50V
RL202
---
100V
70V
100V
RL203 --- 200V 140V 200V
RL204
---
400V
280V
400V
RL205
---
600V
420V
600V
RL206
---
800V
560V
800V
RL207
---
1000V
700V
1000V
Electrical Characteristics @ 25
C Unless Otherwise Specified
Average Forward
Current
I
F(AV)
2 A
T
A
= 75
C
Peak Forward Surge
Current
I
FSM
60A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
V
F
1.0V
I
FM
= 2.0A;
T
A
= 25
C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
R
5.0
A
50
A
T
A
= 25
C
T
A
= 100
C
Typical Junction
Capacitance
C
J
20pF
Measured at
1.0MHz, V
R
=4.0V
*Pulse Test: Pulse Width 300
sec, Duty Cycle 1%
DO-15
A
B
C
D
D
Cathode
Mark
www.
mccsemi
.com
omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
M C C
RL201 thru RL207
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
C
Figure 2
Forward Derating Curve
0
175
50
75
100
125
0
.5
1.0
1.5
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
C
150
2.0
2.5
3.0
Junction Capacitance - pF
versus
Reverse Voltage - Volts
Instantaneous Forward Current - MicroAmperes
versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
4
6
20
10
Amps
.2
.4
.6
.8
1.0
1.2
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25
C
Volts
Figure 3
Junction Capacitance
.1
.2
1
.4
2
10
20
40
4
100 200
1
2
6
10
20
100
pF
Volts
60
40
4
400
1000
T
J
=25
C
www.
mccsemi
.com
M C C
RL201 thru RL207
1
100
4
0
20
40
60
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20
60 80
40
80
100
120
Figure 4
Typical Reverse Characteristics
Volts
.4
.6
2
1
Amps
20
120
40
60
80
100
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
140
T
J
=25
C
T
J
=100
C
Instantaneous Reverse Current - Amps
versus
Percent Of Rated Peak Reverse Voltage - Volts
www.
mccsemi
.com
M C C