1
Precision EdgeTM
SY10ELT20V
SY100ELT20V
Micrel
Pin
Function
Q
Differential PECL Output
D
TTL Input
V
CC
+5V/+3.3V Supply
GND
Ground
DESCRIPTION
s
3.3V and 5V power supply options
s
300ps typical propagation delay
s
Low power
s
Differential PECL output
s
PNP TTL input for minimal loading
s
Flow-through pinouts
s
Available in 8-pin SOIC package and in die form
The SY10/100ELT20V is a single TTL-to-differential
PECL translator. Because PECL (Positive ECL) levels
are used, either +5V or +3.3V and ground are required.
The small outline 8-lead SOIC package and low skew
single gate design make the ELT20V ideal for applications
that require the translation of a clock or data signal where
minimal space, low power, and low cost are critical.
The ELT20V is available in both ECL standards: the
10ELT is compatible with positive ECL 10H logic levels,
while the 100ELT is compatible with positive ECL 100K
logic levels.
FEATURES
PIN NAMES
PIN CONFIGURATION/BLOCK DIAGRAM
SOIC
TOP VIEW
Precision EdgeTM
SY10ELT20V
SY100ELT20V
1
NC
Q
Q
NC
8
V
CC
D
NC
GND
7
6
5
2
3
4
PECL
TTL
Rev.: C
Amendment: /0
Issue Date:
June 2003
Precision Edge is a trademark of Micrel, Inc.
Precision EdgeTM
5V/3.3V TTL-TO-DIFFERENTIAL
PECL TRANSLATOR
2
Precision EdgeTM
SY10ELT20V
SY100ELT20V
Micrel
T
A
= 40
C
T
A
= 0
C
T
A
= +25
C
T
A
= +85
C
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
Condition
I
CC
Power Supply Current
--
20
--
20
--
--
20
--
20
mA
--
TRUTH TABLE
D
Q
Q
H
H
L
L
L
H
Open
H
L
DC ELECTRICAL CHARACTERISTICS
V
CC
= +3.3V
10% or +5.0V
10%
Symbol
Paramter
Value
Unit
V
CC
Power Supply Voltage
0.5 to +7.0
V
V
I
TTL Input Voltage
0.5 to V
CC
V
I
I
TTL Input Current
30 to +5.0
mA
I
OUT
PECL Output Current
mA
Continuous
50
Surge
100
T
store
Storage Temperature
65 to +150
C
T
A
Operating Temperature
40 to +85
C
ABSOLUTE MAXIMUM RATINGS
(Note 1)
T
A
= 40
C
T
A
= 0
C
T
A
= +25
C
T
A
= +85
C
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
Condition
V
IH
Input HIGH Voltage
2.0
--
2.0
--
2.0
--
2.0
--
V
--
V
IL
Input LOW Voltage
--
0.8
--
0.8
--
0.8
--
0.8
V
--
I
IH
Input HIGH Current
--
20
--
20
--
20
--
20
A
V
IN
= 2.7V
--
100
--
100
--
100
--
100
V
IN
= V
CC
I
IL
Input LOW Current
--
0.2
--
0.2
--
0.2
--
0.2
mA
V
IN
= 0.5V
V
IK
Input Clamp Voltage
--
1.2
--
1.2
--
1.2
--
1.2
V
I
IN
= 18mA
TTL DC ELECTRICAL CHARACTERISTICS
V
CC
= +3.3V
10% or +5.0V
10%
T
A
= 40
C
T
A
= 0
C
T
A
= +25
C
T
A
= +85
C
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
Condition
V
OH
Output HIGH Voltage
(Note 2)
mV
10ELT
3920
4110
3980
4160
4020
--
4190
4090
4280
100ELT
3915
4120
3975
4120
3975
--
4120
3975
4120
V
OL
Output LOW Voltage
(1)
mV
10ELT
3050
3350
3050
3370
3050
--
3370
3050
3405
100ELT
3170
3445
3190
3380
3190
--
3380
3190
3380
PECL DC ELECTRICAL CHARACTERISTICS
V
CC
= +3.3V
10% or +5.0V
10%
3
Precision EdgeTM
SY10ELT20V
SY100ELT20V
Micrel
PRODUCT ORDERING INFORMATION
(NOTE 1)
Ordering
Package
Operating
Marking
Code
Type
Range
Code
SY10ELT20VZC
Z8-1
Commercial
HEL20V
SY10ELT20VZCTR
(3)
Z8-1
Commercial
HEL20V
SY100ELT20VZC
Z8-1
Commercial
XEL20V
SY100ELT20VZCTR
(3)
Z8-1
Commercial
XEL20V
T
A
= 40
C
T
A
= 0
C
T
A
= +25
C
T
A
= +85
C
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max. Unit
Condition
t
PLH
Propagation Delay
(Note 3)
100
600
100
600
100
--
600
100
600
ps
50
to V
CC
2.0V
t
PHL
t
skpp
Part-to-Part Skew
(Note 4)
--
500
--
500
--
--
500
--
500
ps
50
to V
CC
2.0V
f
MAX
Maximum Input Frequency
350
--
350
--
350
--
--
350
--
MHz
50
to V
CC
2.0V
t
r
Output Rise/Fall Time
200
500
200
500
200
--
500
200
500
ps
50
to V
CC
2.0V
t
f
(20% to 80%)
AC ELECTRICAL CHARACTERISTICS
(Note 3)
V
CC
= +3.3V
10% or +5.0V
10%
Ordering
Package
Operating
Marking
Code
Type
Range
Code
SY10ELT20VZI
(2)
Z8-1
Industrial
HEL20V
SY10ELT20VZITR
(2,3)
Z8-1
Industrial
HEL20V
SY100ELT20VZI
(2)
Z8-1
Industrial
XEL20V
SY100ELT20VZITR
(2,3)
Z8-1
Industrial
XEL20V
SY100ELT20VXC
DIE
25
C
--
Note 1.
Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded. This is a stress rating only and functional operation
is not implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to ABSOLUTE MAXIMUM
RATlNG conditions for extended periods may affect device reliability.
Note 2.
These values are for VCC = 5.0V. Level Specifications will vary 1:1 with VCC.
Note 3.
Input Rise Time < 1.0ns.
Note 4.
Guaranteed by design. Not tested in production.
4
Precision EdgeTM
SY10ELT20V
SY100ELT20V
Micrel
TOPOGRAPHIES AND PAD COORDINATES
V
CC
(Pad 7)
D
(Pad 8)
NC
(Pad 9)
GND
(Pad 10)
GND
(Pad 1)
NC
(Pad 2)
NC
(Pad 3)
/Q
(Pad 4)
Q
(Pad 5)
V
CC
(Pad 6)
0.850 mm
0.850 mm
Figure 1. Chip Topographies
PAD COORDINATES TABLE
Pad Number
Coordinates (
m)
(4)
1
619.5, 344.5
2
396.5, 344.5
3
130.5, 344.5
4
135.5, 344.5
5
401.5, 344.5
6
619.5, 344.5
7
619.5, 344.5
8
427.5, 344.5
9
427.5, 344.5
10
619.5, 344.5
CHIP INFORMATION
Transistor Count:
98
Substrate:
Connect to GND
Process:
Bipolar
Note 1.
Contact factory for die availability. Die is guaranteed at T
A
= 25
C, DC electricals only. Shipped in waffle pack.
Note 2.
Recommended for new designs.
Note 3.
Tape and Reel.
Note 4.
Coordinates reference from the center of the die.
5
Precision EdgeTM
SY10ELT20V
SY100ELT20V
Micrel
8 LEAD SOIC .150" WIDE (Z8-1)
Rev. 03
MICREL, INC.
1849 FORTUNE DRIVE
SAN JOSE, CA 95131
USA
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 944-0970
WEB
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser's
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser's own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
2003 Micrel, Incorporated.