ChipFind - документация

Электронный компонент: 24AA16SL

Скачать:  PDF   ZIP

Document Outline

1996 Microchip Technology Inc.
DS21054E-page 1
FEATURES
Single supply with operation down to 1.8V
Low power CMOS technology
- 1 mA active current typical
- 10
A standby current typical at 5.5V
- 3
A standby current typical at 1.8V
Organized as 8 blocks of 256 bytes (8 x 256 x 8)
2-wire serial interface bus, I
2
C
TM
compatible
Schmitt trigger, filtered inputs for noise suppres-
sion
Output slope control to eliminate ground bounce
100 kHz (1.8V) and 400 kHz (5V) compatibility
Self-timed write cycle (including auto-erase)
Page-write buffer for up to 16 bytes
2 ms typical write cycle time for page-write
Hardware write protect for entire memory
Can be operated as a serial ROM
ESD protection > 4,000V
10,000,000 erase/write cycles guaranteed
Data retention > 200 years
8-pin DIP, 8-lead or 14-lead SOIC packages
Available for extended temperature ranges
DESCRIPTION
The Microchip Technology Inc. 24AA16 is a 1.8 volt 16K
bit Electrically Erasable PROM. The device is orga-
nized as eight blocks of 256 x 8-bit memory with a 2-
wire serial interface. Low voltage design permits oper-
ation down to 1.8 volts with standby and active currents
of only 3
A and 1 mA, respectively. The 24AA16 also
has a page-write capability for up to 16 bytes of data.
The 24AA16 is available in the standard 8-pin DIP and
both 8-lead and 14-lead surface mount SOIC pack-
ages.
- Commercial (C):
0C to +70
C
- Industrial (I):
-40
C to +85
C
PACKAGE TYPES
BLOCK DIAGRAM
14-lead SOIC
NC
SS
CC
A0
A1
NC
A2
NC
V
1
2
3
4
5
6
7
14
13
12
NC
SCL
SDA
NC
9
8
11
10
WP
V
NC
24AA16
24AA16
A0
A1
A2
V
SS
1
2
3
4
8
7
6
5
V
CC
WP
SCL
SDA
24AA16
A0
A1
A2
V
SS
1
2
3
4
8
7
6
5
V
CC
WP
SCL
SDA
PDIP
8-lead
SOIC
HV GENERATOR
EEPROM
ARRAY
PAGE LATCHES
YDEC
XDEC
SENSE AMP
R/W CONTROL
MEMORY
CONTROL
LOGIC
I/O
CONTROL
LOGIC
WP
SDA
SCL
V
CC
V
SS
24AA16
16K 1.8V I
2
C
TM
Serial EEPROM
I
2
C is a trademark of Philips Corporation.
This document was created with FrameMaker 4 0 4
24AA16
DS21054E-page 2
1996 Microchip Technology Inc.
1.0
ELECTRICAL CHARACTERISTICS
1.1
Maximum Ratings*
V
CC
...................................................................................7.0V
All inputs and outputs w.r.t. V
SS .................
-0.6V to V
CC
+1.0V
Storage temperature ..................................... -65C to +150C
Ambient temp. with power applied ................ -65C to +125C
Soldering temperature of leads (10 seconds) ............. +300C
ESD protection on all pins
..................................................
4 kV
*Notice:
Stresses above those listed under "Maximum ratings"
may cause permanent damage to the device. This is a stress rat-
ing only and functional operation of the device at those or any
other conditions above those indicated in the operational listings
of this specification is not implied. Exposure to maximum rating
conditions for extended periods may affect device reliability
TABLE 1-1:
PIN FUNCTION TABLE
Name
Function
V
SS
Ground
SDA
Serial Address/Data I/O
SCL
Serial Clock
WP
Write Protect Input
V
CC
+1.8V to 5.5V Power Supply
A0, A1, A2
No Internal Connection
TABLE 1-2:
DC CHARACTERISTICS
FIGURE 1-1:
BUS TIMING START/STOP
V
CC
= 1.8V to +5.5V
Commercial (C): Tamb = 0C to +70C
Industrial (I): Tamb = -40
C to +85
C
Parameter
Symbol
Min
Typ
Max
Units
Conditions
WP, SCL and SDA pins:
High level input voltage
V
IH
.7 V
CC
--
V
Low level input voltage
V
IL
--
.3 V
CC
V
Hysteresis of Schmitt trigger inputs
V
HYS
.05 V
CC
--
V
(Note)
Low level output voltage
V
OL
--
.40
V
I
OL
= 3.0 mA, V
CC
= 1.8V
Input leakage current
I
LI
-10
10
A
V
IN
= .1V to V
CC
Output leakage current
I
LO
-10
10
A
V
OUT
= .1V to V
CC
Pin capacitance
(all inputs/outputs
C
IN
,
C
OUT
--
10
pF
V
CC
= 5.0V (Note 1)
Tamb = 25C, F
CLK
= 1 MHz
Operating current
I
CC
Write
I
CC
Read
--
--
--
--
--
0.5
--
0.05
3
--
1
--
mA
mA
mA
mA
V
CC
= 5.5V, SCL = 400 kHz
V
CC
= 1.8V, SCL = 100 kHz
V
CC
= 5.5V, SCL = 400 kHz
V
CC
= 1.8V, SCL = 100 kHz
Standby current
I
CCS
--
--
--
--
--
3
100
30
--
A
A
A
V
CC
= 5.5V, SDA=SCL=V
CC
V
CC
= 3.0V, SDA=SCL=V
CC
V
CC
= 1.8V, SDA=SCL=V
CC
Note: This parameter is periodically sampled and not 100% tested.
T
SU
:
STA
T
HD
:
STA
V
HYS
T
SU
:
STO
START
STOP
SCL
SDA
1996 Microchip Technology Inc.
DS21054E-page 3
24AA16
TABLE 1-3:
AC CHARACTERISTICS
FIGURE 1-2:
BUS TIMING DATA
Parameter
Symbol
STANDARD
MODE
V
CC
= 4.5-5.5V
FAST MODE
Units
Remarks
Min
Max
Min
Max
Clock frequency
F
CLK
--
100
--
400
kHz
Clock high time
T
HIGH
4000
--
600
--
ns
Clock low time
T
LOW
4700
--
1300
--
ns
SDA and SCL rise time
T
R
--
1000
--
300
ns
(Note 1)
SDA and SCL fall time
T
F
--
300
--
300
ns
(Note 1)
START condition hold
time
T
HD
:
STA
4000
--
600
--
ns
After this period the first
clock pulse is generated
START condition setup
time
T
SU
:
STA
4700
--
600
--
ns
Only relevant for repeated
START condition
Data input hold time
T
HD
:
DAT
0
--
0
--
ns
Data input setup time
T
SU
:
DAT
250
--
100
--
ns
STOP condition setup
time
T
SU
:
STO
4000
--
600
--
ns
Output valid from clock
T
AA
--
3500
--
900
ns
(Note 2)
Bus free time
T
BUF
4700
--
1300
--
ns
Time the bus must be free
before a new transmission
can start
Output fall time from V
IH
min to V
IL
max
T
OF
--
250
20 +0.1
C
B
250
ns
(Note 1), C
B
100 pF
Input filter spike suppres-
sion (SDA and SCL pins)
T
SP
--
50
--
50
ns
(Note 3)
Write cycle time
T
WR
--
10
--
10
ms
Byte or Page mode
Endurance
--
10M
--
10M
--
cycles
25
C, Vcc = 5.0V, Block
Mode (Note 4)
Note 1: Not 100% tested. C
B
= total capacitance of one bus line in pF.
2: As a transmitter, the device must provide an internal minimum delay time to bridge the undefined region
(minimum 300 ns) of the falling edge of SCL to avoid unintended generation of START or STOP conditions
3: The combined T
SP
and V
HYS
=specifications are due to new Schmitt trigger inputs which provide improved
noise and spike suppression. This eliminates the need for a T
I
specification for standard operation.
4: This parameter is not tested but guaranteed by characterization. For endurance estimates in a specific appli-
cation, please consult the Total Endurance Model which can be obtained on our BBS or website.
T
SU
:
STA
T
F
T
LOW
T
HIGH
T
R
T
HD
:
DAT
T
SU
:
DAT
T
SU
:
STO
T
HD
:
STA
T
BUF
T
AA
T
AA
T
SP
T
HD
:
STA
SCL
SDA
IN
SDA
OUT
24AA16
DS21054E-page 4
1996 Microchip Technology Inc.
2.0
FUNCTIONAL DESCRIPTION
The 24AA16 supports a Bi-directional 2-wire bus and
data transmission protocol. A device that sends data
onto the bus is defined as transmitter, and a device
receiving data as receiver. The bus has to be controlled
by a master device which generates the serial clock
(SCL), controls the bus access, and generates the
START and STOP conditions, while the 24AA16 works
as slave. Both, master and slave can operate as trans-
mitter or receiver but the master device determines
which mode is activated.
3.0
BUS CHARACTERISTICS
The following bus protocol has been defined:
Data transfer may be initiated only when the bus is
not busy.
During data transfer, the data line must remain
stable whenever the clock line is HIGH. Changes
in the data line while the clock line is HIGH will be
interpreted as a START or STOP condition.
Accordingly, the following bus conditions have been
defined (Figure 3-1).
3.1
Bus not Busy (A)
Both data and clock lines remain HIGH.
3.2
Start Data Transfer (B)
A HIGH to LOW transition of the SDA line while the
clock (SCL) is HIGH determines a START condition. All
commands must be preceded by a START condition.
3.3
Stop Data Transfer (C)
A LOW to HIGH transition of the SDA line while the
clock (SCL) is HIGH determines a STOP condition. All
operations must be ended with a STOP condition.
3.4
Data Valid (D)
The state of the data line represents valid data when,
after a START condition, the data line is stable for the
duration of the HIGH period of the clock signal.
The data on the line must be changed during the LOW
period of the clock signal. There is one clock pulse per
bit of data.
Each data transfer is initiated with a START condition
and terminated with a STOP condition. The number of
the data bytes transferred between the START and
STOP conditions is determined by the master device
and is theoretically unlimited, although only the last 16
will be stored when doing a write operation. When an
overwrite does occur it will replace data in a first in first
out fashion.
3.5
Acknowledge
Each receiving device, when addressed, is obliged to
generate an acknowledge after the reception of each
byte. The master device must generate an extra clock
pulse which is associated with this acknowledge bit.
The device that acknowledges, has to pull down the
SDA line during the acknowledge clock pulse in such a
way that the SDA line is stable LOW during the HIGH
period of the acknowledge related clock pulse. Of
course, setup and hold times must be taken into
account. A master must signal an end of data to the
slave by not generating an acknowledge bit on the last
byte that has been clocked out of the slave. In this
case, the slave must leave the data line HIGH to enable
the master to generate the STOP condition.
Note:
The 24AA16 does not generate any
acknowledge bits if an internal program-
ming cycle is in progress.
FIGURE 3-1:
DATA TRANSFER SEQUENCE ON THE SERIAL BUS
(A)
(B)
(D)
(D)
(A)
(C)
START
CONDITION
ADDRESS OR
ACKNOWLEDGE
VALID
DATA
ALLOWED
TO CHANGE
STOP
CONDITION
SCL
SDA
1996 Microchip Technology Inc.
DS21054E-page 5
24AA16
3.6
Device Addressing
A control byte is the first byte received following the start
condition from the master device. The control byte con-
sists of a 4-bit control code, for the 24AA16 this is set as
1010 binary for read and write operations. The next three
bits of the control byte are the block select bits (B2, B1,
B0). They are used by the master device to select which
of the eight 256 word blocks of memory are to be
accessed. These bits are in effect the three most signifi-
cant bits of the word address. It should be noted that the
protocol limits the size of the memory to eight blocks of
256 words, therefore the protocol can support only one
24AA16 per system.
The last bit of the control byte defines the operation to
be performed. When set to one a read operation is
selected, when set to zero a write operation is selected.
Following the start condition, the 24AA16 monitors the
SDA bus checking the device type identifier being
transmitted, upon a 1010 code the slave device outputs
an acknowledge signal on the SDA line. Depending on
the state of the R/W bit, the 24AA16 will select a read
or write operation.
FIGURE 3-2:
CONTROL BYTE
ALLOCATION
Operation
Control
Code
Block Select
R/W
Read
1010
Block Address
1
Write
1010
Block Address
0
SLAVE ADDRESS
R/W
A
START
READ/WRITE
X = Don't care
1
0
1
0
B2
B1
B0
4.0
WRITE OPERATION
4.1
Byte Write
Following the start condition from the master, the
device code (4 bits), the block address (3 bits), and the
R/W bit which is a logic low is placed onto the bus by
the master transmitter. This indicates to the addressed
slave receiver that a byte with a word address will follow
after it has generated an acknowledge bit during the
ninth clock cycle. Therefore the next byte transmitted by
the master is the word address and will be written into
the address pointer of the 24AA16. After receiving
another acknowledge signal from the 24AA16 the mas-
ter device will transmit the data word to be written into
the addressed memory location. The 24AA16 acknowl-
edges again and the master generates a stop condi-
tion. This initiates the internal write cycle, and during
this time the 24AA16 will not generate acknowledge
signals (Figure 4-1).
4.2
Page Write
The write control byte, word address and the first data
byte are transmitted to the 24AA16 in the same way as
in a byte write. But instead of generating a stop condi-
tion the master transmits up to sixteen data bytes to the
24AA16 which are temporarily stored in the on-chip
page buffer and will be written into the memory after the
master has transmitted a stop condition. After the
receipt of each word, the four lower order address
pointer bits are internally incremented by one. The
higher order seven bits of the word address remains
constant. If the master should transmit more than 16
words prior to generating the stop condition, the
address counter will roll over and the previously
received data will be overwritten. As with the byte write
operation, once the stop condition is received an inter-
nal write cycle will begin (Figure 4-2).
FIGURE 4-1:
BYTE WRITE
FIGURE 4-2:
PAGE WRITE
S
P
BUS ACTIVITY
MASTER
SDA LINE
BUS ACTIVITY
S
T
A
R
T
S
T
O
P
CONTROL
BYTE
WORD
ADDRESS
DATA
A
C
K
A
C
K
A
C
K
S
P
BUS ACTIVITY
MASTER
SDA LINE
BUS ACTIVITY
S
T
A
R
T
CONTROL
BYTE
WORD
ADDRESS (n)
DATA n
DATA n + 15
S
T
O
P
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
DATA n + 1