ChipFind - документация

Электронный компонент: MKW2547

Скачать:  PDF   ZIP
Dual Output
+Vo
PWM
Isolation
Ref.Amp
LC
Filter
+Vin
-Vin
Com.
-Vo
Single Output
PWM
Isolation
Ref.Amp
LC
Filter
+Vin
-Vin
-Vo
+Vo
Block Diagram
Remote on/off
EN55022
EMI
I/O Isolation
1500
VDC
More Power
High
Power
Density
Wide Range
2:1
Minmax's MKW2500 series, comprising 21 different models, has
been conceived as an application specific range of DC/DC converters,
specially addressing data communication equipments, mobile battery
driven equipments, distributed power systems, telecommunication
equipments, mixed analog/digital subsystems, process/machine control
equipments, computer peripheral systems and industrial robot systems.
Packing up to 15W of power into a 2x1x0.4 inch package, with
efficiency as high as 86%, the MKW2500 has wide input ranges of
9-18VDC, 18-36VDC and 36-75VDC which is available in output
voltages of 3.3V, 5V, 5.1V, 12V, 15V, {12V and {15VDC.
Other feathers include continuous short circuit protection, remote
on/off, six-sided shielded case and EN55022 Class A conducted noise
compliance minimize design-in time, cost and eliminate the need for
external filtering.
Internal SMD Construction
UL 94V-0 Package Material
Remote On/Off Control
Six-Sided Shielding
Complies with EN55022 Class A
CSA1950 Safety Approval
2:1 Wide Input Range
MTBF > 700,000 Hours
1500VDC Isolation
Efficiency up to 86%
Key Features
15W, Wide Input Range, Single & Dual Output DC/DC Converters
MKW2500 Series
REV:0 2005/04
MINMAX
1
81
393
300
3000
5.1
MKW2549
86
363
{50
{500
{15
MKW2547
86
363
{62.5
{625
{12
MKW2546
86
363
100
1000
15
MKW2544
86
363
125
1250
12
MKW2543
82
381
300
3000
5
MKW2542
78
30
10
264
300
3000
3.3
48
( 36 ~ 75 )
MKW2541
81
787
300
3000
5.1
MKW2539
86
726
{50
{500
{15
MKW2537
86
726
{62.5
{625
{12
MKW2536
86
726
100
1000
15
MKW2534
86
726
125
1250
12
MKW2533
82
762
300
3000
5
MKW2532
78
40
20
528
300
3000
3.3
24
( 18 ~ 36 )
MKW2531
81
1574
300
3000
5.1
MKW2529
86
1452
{50
{500
{15
MKW2527
86
1452
{62.5
{625
{12
MKW2526
86
1452
100
1000
15
MKW2524
86
1452
125
1250
12
MKW2523
82
1524
300
3000
5
MKW2522
78
50
30
1057
300
3000
3.3
12
( 9 ~ 18 )
MKW2521
% (Typ.)
mA (Typ.)
mA (Typ.)
mA (Typ.)
mA
mA
VDC
VDC
@Max. Load
@No Load
@Max. Load
Min.
Max.
Efficiency
Reflected
Ripple
Current
Input Current
Output Current
Output
Voltage
Input
Voltage
Model
Number
Model Selection Guide
EN55022 Class A
Conducted EMI
Six-Sided Shielded, Metal Case
RFI
Free-Air Convection
Cooling
%
95
---
Humidity
]
+125
-50
Storage Temperature
]
+100
-40
Case
Operating Temperature
]
+60
-40
Ambient
Operating Temperature
Unit
Max.
Min.
Conditions
Parameter
Environmental Specifications
Exceeding the absolute maximum ratings of the unit could cause damage.
These are not continuous operating ratings.
mW
5,000
---
Internal Power Dissipation
]
260
---
Lead Temperature (1.5mm from case for 10 Sec.)
VDC
100
-0.7
48VDC Input Models
VDC
50
-0.7
24VDC Input Models
VDC
25
-0.7
12VDC Input Models
Input Surge Voltage
( 1000 mS )
Unit
Max.
Min.
Parameter
Notes :
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Transient recovery time is measured to within 1%
error band for a step change in output load of 75%
to 100%.
3. Ripple & Noise measurement bandwidth is 0-20
MHz.
4. These power converters require a minimum output
loading to maintain specified regulation.
5. Operation under no-load conditions will not damage
these modules; however, they may not meet all
specifications listed.
6. All DC/DC converters should be externally fused at
the front end for protection.
7. Other input and output voltage may be available,
please contact factory.
8. To order the converter with Remote On/Off function,
please add a suffix -RC (e.g. MKW2521-RC).
9. To order the converter with EN55022 Class A
function, please add a suffix A (e.g. MKW2521A).
10. Specifications subject to change without notice.
Absolute Maximum Ratings
MKW2500 Series
2
MINMAX
REV:0 2005/04
Pi Filter
Input Filter
mW
3500
---
---
Short Circuit Input Power
A
1
---
---
All Models
Reverse Polarity Input Current
34
29
25
48V Input Models
17
15
13
24V Input Models
8.5
8
7
12V Input Models
Under Voltage Shutdown
36
33
30
48V Input Models
18
17
15
24V Input Models
VDC
9
8.5
8
12V Input Models
Start Voltage
Unit
Max.
Typ.
Min.
Model
Parameter
Input Specifications
Continuous
Output Short Circuit
%/]
{0.02
{0.01
---
Temperature Coefficient
%
{4
{2
---
Transient Response Deviation
uS
500
300
---
25% Load Step Change
Transient Recovery Time
%
---
---
120
Over Power Protection
mV rms
15
---
---
Ripple & Noise (20MHz)
mV P-P
100
---
---
Over Line, Load & Temp
Ripple & Noise (20MHz)
mV P-P
80
55
---
Ripple & Noise (20MHz)
%
{1.0
{0.5
---
Io=10% to 100%
Load Regulation
%
{0.5
{0.1
---
Vin=Min. to Max.
Line Regulation
%
{2.0
{0.5
---
Dual Output, Balanced Loads
Output Voltage Balance
%
{2.0
{1.0
---
Output Voltage Accuracy
Unit
Max.
Typ.
Min.
Conditions
Parameter
Output Specifications
K Hours
---
---
700
MIL-HDBK-217F @ 25], Ground Benign
MTBF
KHz
400
330
290
Switching Frequency
pF
1500
1200
---
100KHz,1V
Isolation Capacitance
M[
---
---
1000
500VDC
Isolation Resistance
VDC
---
---
1650
Flash Tested for 1 Second
Isolation Voltage Test
VDC
---
---
1500
60 Seconds
Isolation Voltage Rated
Unit
Max.
Typ.
Min.
Conditions
Parameter
General Specifications
Referenced to Negative Input
Control Common
mA
-1
---
---
Vin-RC=0V
Control Input Current ( off )
uA
50
---
---
Vin-RC=5.0V
Control Input Current ( on )
mA
10
---
---
Standby Input Current
VDC
0.8
---
-0.7
Supply Off
2.5 to 5.5VDC or Open Circuit
Supply On
Unit
Max.
Typ.
Min.
Conditions
Parameter
Remote On/Off Control
MKW2500 Series
REV:0 2005/04
MINMAX
3
# For each output
uF
220
220
470
470
470
470
470
Maximum Capacitive Load
Unit
{15V #
{12V #
15V
12V
5.1V
5V
3.3V
Models by Vout
Capacitive Load
750mA Slow - Blow Type
1250mA Slow - Blow Type
2500mA Slow - Blow Type
48V Input Models
24V Input Models
12V Input Models
Input Fuse Selection Guide
Vin ( VDC )
10uS
150
140
130
120
110
100
90
80
70
60
100uS
1mS
10mS
100mS
50
40
30
20
10
0
48VDC Input Models
24VDC Input Models
12VDC Input Models
Input Voltage Transient Rating
MKW2500 Series
4
MINMAX
REV:0 2005/04
Derating Curve
]
Ambient Temperature
Output Power (%)
0
20
40
60
80
100
-40
50
60
80
100
110
90
70
400LFM
200LFM
100LFM
Natural
convection
Efficiency vs Output Load ( Dual Output )
Efficiency vs Output Load ( Single Output )
30
40
50
60
70
80
90
100
Load Current (%)
Efficiency (%)
100
60
40
20
10
80
30
40
50
60
70
80
90
Load Current (%)
Efficiency (%)
100
60
40
20
10
80
Efficiency vs Input Voltage ( Dual Output )
Efficiency vs Input Voltage ( Single Output )
50
60
70
80
90
100
Input Voltage (V)
Efficiency (%)
Nom
Low
High
50
60
70
80
90
100
Input Voltage (V)
Efficiency (%)
Nom
Low
High
MKW2500 Series
REV:0 2005/04
MINMAX
5