Sep.'99 Preliminary
MITSUBISHI LSIs
MITSUBISHI
ELECTRIC
DDR SDRAM (Rev.0.0)
M2S56D20/ 30 TP
256M Double Data Rate Synchronous DRAM
1
M2S56D20TP is a 4-bank x 16777216-word x 4-bit,
M2S56D30TP is a 4-bank x 8388608-word x 8-bit,
double data rate synchronous DRAM, with SSTL_2 interface. All control and address signals are
referenced to the rising edge of CLK. Input data is registered on both edges of data strobe, and output
data and data strobe are referenced on both edges of CLK. The M2S56D20/30 TP achieves very high
speed data rate up to 133MHz, and are suitable for main memory in computer systems.
- Vdd=Vddq=2.5v0.2V
- Double data rate architecture;
two data transfers per clock cycle
- Bidirectional, data strobe (DQS) is transmitted/received with data
- Differential clock inputs (CLK and /CLK)
- DLL aligns DQ and DQS transitions
with CLK transitions edges of DQS
- Commands entered on each positive CLK edge;
- data and data mask referenced to both edges of DQS
- 4 bank operation controlled by BA0, BA1 (Bank Address)
- /CAS latency- 1.5/2.0/2.5 (programmable)
- Burst length- 2/4/8 (programmable)
- Burst type- sequential / interleave (programmable)
- Auto precharge / All bank precharge controlled by A10
- 8192 refresh cycles /64ms (4 banks concurrent refresh)
- Auto refresh and Self refresh
- Row address A0-12 / Column address A0-9,11(x4)/ A0-9(x8)
- SSTL_2 Interface
- 400-mil, 66-pin Thin Small Outline Package (TSOP II)
- FET switch control(/QFC)
- JEDEC standard
PRELIMINARY
Some of contents are subject to change without notice.
DESCRIPTION
FEATURES
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
VDD
DQ0
VDDQ
NC
DQ1
VSSQ
NC
DQ2
VDDQ
NC
DQ3
VSSQ
NC
NC
VDDQ
NC
NC
VDD
NU/QFC
NC
/WE
/CAS
/RAS
/CS
NC
BA0
BA1
A10/AP
A0
A1
A2
A3
VDD
VSS
DQ7
VSSQ
NC
DQ6
VDDQ
NC
DQ5
VSSQ
NC
DQ4
VDDQ
NC
NC
VSSQ
DQS
NC
VREF
VSS
DM
/CLK
CLK
CKE
NC
A12
A11
A9
A8
A7
A6
A5
A4
VSS
66pin TSOP(II)
400mil width
x
875mil length
0.65mm
Lead Pitch
ROW
A0-12
Column
A0-9,11(x4)
A0-9 (x8)
x8
PIN CONFIGURATION
(TOP VIEW)
Sep.'99 Preliminary
MITSUBISHI LSIs
MITSUBISHI
ELECTRIC
DDR SDRAM (Rev.0.0)
M2S56D20/ 30 TP
256M Double Data Rate Synchronous DRAM
2
CLK,/CLK
: Master Clock
CKE
: Clock Enable
/CS
: Chip Select
/RAS
: Row Address Strobe
/CAS
: Column Address Strobe
/WE
: Write Enable
DQ0-7
: Data I/O
DQS
: Data Strobe
DM
: Write Mask
/QFC
: FET Switch Control
Vref
: Reference Voltage
PIN CONFIGURATION
(TOP VIEW)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
VDD
DQ0
VDDQ
NC
DQ1
VSSQ
NC
DQ2
VDDQ
NC
DQ3
VSSQ
NC
NC
VDDQ
NC
NC
VDD
NU,/QFC
NC
/WE
/CAS
/RAS
/CS
NC
BA0
BA1
A10/AP
A0
A1
A2
A3
VDD
VSS
DQ7
VSSQ
NC
DQ6
VDDQ
NC
DQ5
VSSQ
NC
DQ4
VDDQ
NC
NC
VSSQ
DQS
NC
VREF
VSS
DM
/CLK
CLK
CKE
NC
A12
A11
A9
A8
A7
A6
A5
A4
VSS
66pin TSOP(II)
400mil width
x
875mil length
0.65mm
Lead Pitch
ROW
A0-12
Column
A0-9,11(x4)
A0-9 (x8)
VDD
NC
VDDQ
NC
DQ0
VSSQ
NC
NC
VDDQ
NC
DQ1
VSSQ
NC
NC
VDDQ
NC
NC
VDD
NU,/QFC
NC
/WE
/CAS
/RAS
/CS
NC
BA0
BA1
A10/AP
A0
A1
A2
A3
VDD
VSS
NC
VSSQ
NC
DQ3
VDDQ
NC
NC
VSSQ
NC
DQ2
VDDQ
NC
NC
VSSQ
DQS
NC
VREF
VSS
DM
/CLK
CLK
CKE
NC
A12
A11
A9
A8
A7
A6
A5
A4
VSS
x8
x4
A0-12
: Address Input
BA0,1
: Bank Address Input
Vdd
: Power Supply
VddQ
: Power Supply for Output
Vss
: Ground
VssQ
: Ground for Output
Sep.'99 Preliminary
MITSUBISHI LSIs
MITSUBISHI
ELECTRIC
DDR SDRAM (Rev.0.0)
M2S56D20/ 30 TP
256M Double Data Rate Synchronous DRAM
3
Type Designation Code
This rule is applied to only Synchronous DRAM family.
Mitsubishi Main Designation
Speed Grade 10: 125MHz@CL=2.5,100MHz@CL=2.0
75: 133MHz@CL=2.5,100MHz@CL=2.0
Package Type TP: TSOP(II)
Process Generation
Function Reserved for Future Use
Organization 2n 2: x4, 3: x8
DDR Synchronous DRAM
Density 56: 256M bits
Interface V:LVTTL, S:SSTL_3, _2
Memory Style (DRAM)
M 2 S 56 D 3 0
TP -
BLOCK DIAGRAM
/CS /RAS /CAS /WE
DM
Memory
Array
Bank #0
DQ0 - 7
I/O Buffer
Memory
Array
Bank #1
Memory
Array
Bank #2
Memory
Array
Bank #3
Mode Register
Control Circuitry
Address Buffer
A0-12
BA0,1
Clock Buffer
CLK,/CLK
CKE
Control Signal Buffer
/QFC
QFC&QS Buffer
DQS
DLL
Sep.'99 Preliminary
MITSUBISHI LSIs
MITSUBISHI
ELECTRIC
DDR SDRAM (Rev.0.0)
M2S56D20/ 30 TP
256M Double Data Rate Synchronous DRAM
4
PIN FUNCTION
CLK,/CLK
Input
Clock: CLK and /CLK are differential clock inputs. All address and control
input signals are sampled on the crossing of the positive edge of CLK and
negative edge of /CLK. Output (read) data is referenced to the crossings of
CLK and /CLK (both directions of crossing).
CKE
Input
Clock Enable: CKE controls internal clock. When CKE is low, internal clock
for the following cycle is ceased. CKE is also used to select auto / self
refresh. After self refresh mode is started, CKE becomes asynchronous
input. Self refresh is maintained as long as CKE is low.
/CS
Input
Chip Select: When /CS is high, any command means No Operation.
/RAS, /CAS, /WE
Input
Combination of /RAS, /CAS, /WE defines basic commands.
A0-12
Input
A0-12 specify the Row / Column Address in conjunction with BA0,1. The
Row Address is specified by A0-12. The Column Address is specified by
A0-9,11(x4) and A0-9(x8). A10 is also used to indicate precharge option.
When A10 is high at a read / write command, an auto precharge is
performed. When A10 is high at a precharge command, all banks are
precharged.
BA0,1
Input
DQ0-7(x8),
DQ0-3(x4)
Input / Output
DQS
Vdd, Vss
Power Supply
Power Supply for the memory array and peripheral circuitry.
VddQ, VssQ
Power Supply
VddQ and VssQ are supplied to the Output Buffers only.
Bank Address: BA0,1 specifies one of four banks to which a command is
applied. BA0,1 must be set with ACT, PRE, READ, WRITE commands.
Data Input/Output: Data bus
Data Strobe: Output with read data, input with write data. Edge-aligned
with read data, centered in write data. Used to capture write data.
SYMBOL
TYPE
DESCRIPTION
/QFC
Output
FET Control: Optional. Output during every Read and Write access. Can
be used to control
isolation switches on modules. Open drain output.
DM
Input
Input Data Mask: DM is an input mask signal for write data. Input data is
masked when DM is sampled HIGH along with that input data during a
WRITE access. DM is sampled on both edges of DQS. Although DM pins
are input only, the DM loading matches the DQ and DQS loading.
Input / Output
Vref
Input
SSTL_2 reference voltage.
Sep.'99 Preliminary
MITSUBISHI LSIs
MITSUBISHI
ELECTRIC
DDR SDRAM (Rev.0.0)
M2S56D20/ 30 TP
256M Double Data Rate Synchronous DRAM
5
BASIC FUNCTIONS
The M2S56D20/30TP provides basic functions, bank (row) activate, burst read / write, bank (row)
precharge, and auto / self refresh. Each command is defined by control signals of /RAS, /CAS and /WE at
CLK rising edge. In addition to 3 signals, /CS ,CKE and A10 are used as chip select, refresh option, and
precharge option, respectively. To know the detailed definition of commands, please see the command
truth table.
/CS
Chip Select : L=select, H=deselect
/RAS
Command
/CAS
Command
/WE
Command
CKE
Refresh Option @refresh command
A10
Precharge Option @precharge or read/write command
CLK
define basic commands
Activate (ACT) [/RAS =L, /CAS =/WE =H]
ACT command activates a row in an idle bank indicated by BA.
Read (READ) [/RAS =H, /CAS =L, /WE =H]
READ command starts burst read from the active bank indicated by BA. First output data appears after
/CAS latency. When A10 =H at this command, the bank is deactivated after the burst read (auto-
precharge,READA)
Write (WRITE) [/RAS =H, /CAS =/WE =L]
WRITE command starts burst write to the active bank indicated by BA. Total data length to be written
is set by burst length. When A10 =H at this command, the bank is deactivated after the burst write (auto-
precharge, WRITEA).
Precharge (PRE) [/RAS =L, /CAS =H, /WE =L]
PRE command deactivates the active bank indicated by BA. This command also terminates burst read
/write operation. When A10 =H at this command, all banks are deactivated (precharge all, PREA).
Auto-Refresh (REFA) [/RAS =/CAS =L, /WE =CKE =H]
REFA command starts auto-refresh cycle. Refresh address including bank address are generated
internally. After this command, the banks are precharged automatically.
/CLK