ChipFind - документация

Электронный компонент: S4EB-L2-24V

Скачать:  PDF   ZIP

Document Outline

219
S-RELAYS
4 AMP POLARIZED HIGH
DENSITY RELAY WITH HIGH
SENSITIVITY
mm
inch
28.0
1.102
12.0
.472
10.4
.409
FEATURES
A variety of contact arrangements 2
Form A 2 Form B, 3 Form A 1 Form B,
4 Form A
Latching types available
High sensitivity in small size 100 mW
pick-up and 200 mW nominal operating
power
High shock and vibration resistance
Shock: 50 G Vibration: 10 to 55 Hz at
double amplitude of 3 mm
.118 inch
Wide switching range From 100
A
100 mV DC to 4 A 250 V AC
Low thermal electromotive force Ap-
prox. 3
V
Dual-In-Line packaging arrangement
Amber types available
SPECIFICATIONS
Contacts
Coil (polarized) (at 20
C
68
F
)
Characteristics (at 25
C
77
F
50% Relative humidity)
Arrangement
2 Form A 2 Form B,
3 Form A 1 Form B,
4 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m
Initial contact pressure
Approx. 12 g
.42 oz
Contact material
Gold clad silver alloy
Electrostatic capacitance
Approx. 3pF
Thermal electromotive force
(at nominal coil voltage)
Approx. 3
V
Rating
(resistive)
Nominal switching capacity
4 A 250 V AC, 3 A 30 V DC
Maximum switching power
1,000 VA, 90 W
Maximum switching voltage
250 V AC, 30 V DC
(48 VDC at less than 0.5 A)
Max. switching current
4 A (AC), 3 A (DC)
Min. switching capacity**
1
100
A 100 m V DC
Expected
life (min.
operations)
Mechanical (at 50 cps)
10
8
Electrical
(at 20 cpm)
4 A 250 V AC
10
5
3 A 30 V DC
2
10
5
Single side
stable
Minimum operating power
Approx. 100 mW
Nominal operating power
Approx. 200 mW
Latching
Minimum set and reset
Approx. 100 mW
Nominal set and reset
Approx. 200 mW
Max. operating speed
20 cpm for maximum load,
50 cps for low-level load
(1 mA 1 V DC)
Initial insulation resistance*
1
10,000 M
at 500 V DC
Initial
breakdown
voltage*
2
Between open contacts
750 Vrms
Between contact sets
1,000 Vrms
Between contacts and
coil
1,500 Vrms
Operate time*
3
(at nominal voltage)(at 20
C)
Max. 15 ms (Approx. 8 ms)
Release time (without diode)*
3
(at nominal voltage)(at 20
C)
Max. 10 ms (Approx. 5 ms)
Set time*
3
(latching)
(at nominal voltage)(at 20
C)
Max. 15 ms (Approx. 8 ms)
Reset time*
3
(latching)
(at nominal voltage)(at 20
C)
Max. 15 ms (Approx. 8 ms)
Initial contact bounce, max.
1 ms
Temperature rise
(at nominal voltage)(at 20
C)
Max. 35
C with nominal coil
voltage and at maximum
switching current
Shock resistance
Functional*
4
Min. 490 m/s
2
{50 G}
Destructive*
5
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
6
176.4 m/s
2
{18 G}, 10 to 55 Hz
at double amplitude of 3 mm
Destructive
235.2 m/s
2
{24 G}, 10 to 55 Hz
at double amplitude of 4 mm
Conditions for operation,
transport and storage*
7
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
40
C to +65
C
40
F to +149
F
Humidity
5 to 85% R.H.
Unit weight
Approx. 8 g
.28 oz
Notes:
**
1
This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the ac-
tual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage "section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10
s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
TYPICAL APPLICATIONS
Telecommunications equipment, data processing equipment,
facsimiles, alarm equipment, measuring equipment.
S
220
Ex.
Contact arrangement
Classification of type
2: 2 Form A 2 Form B
3: 3 Form A 1 Form B
4: 4 Form A
EB: Amber sealed type
Operating function
Nil: Single side stable
L2: 2 coil latching
Coil voltage (DC)
3, 5, 6, 12, 24, 48 V
S
2
EB
L2
48V
(Notes) 1. Standard packing Carton: 50 pcs. Case: 500 pcs.
2. 1 coil latching also available as option. Contact our sales office for details.
3. UL/CSA approved type is standard.
TYPES AND COIL DATA at 20
C
68
F
Single side stable
2 coil latching
Note: Insert 2, 3 or 4 in
u
for contact form reguired.
Type
Nominal
voltage,
V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Nominal
operating
current,
mA
Coil resistance,
(
10%)
Inductance,
mH
Nominal
operating
power,
mW
Maximum
allowable
voltage,
V DC (40
C)
S
u
EB-3V
3
2.1
0.3
66.7
45
23
200
5.5
S
u
EB-5V
5
3.5
0.5
38.5
130
65
192
9.0
S
u
EB-6V
6
4.2
0.6
33.3
180
93
200
11.0
S
u
EB-12V
12
8.4
1.2
16.7
720
370
200
22.0
S
u
EB-24V
24
16.8
2.4
8.4
2,850
1,427
202
44.0
S
u
EB-48V
48
33.6
4.8
5.6
8,500
3,410
271
75.0
Type
Nominal voltage,
V DC
Set and reset
voltage,
V DC (max.)
Nominal operating
current,
mA
Coil resistance,
(
10%)
Inductance,
mH
Nominal
operating
power,
mW
Maximum
allowable
voltage,
V DC (40
C)
Coil I
Coil II
Coil I
Coil II
S
u
EB-L2-3V
3
2.1
66.7
45
45
10
10
200
5.5
S
u
EB-L2-5V
5
3.5
38.5
130
130
31
31
192
9.0
S
u
EB-L2-6V
6
4.2
33.7
180
180
40
40
200
11.0
S
u
EB-L2-12V
12
8.4
16.7
720
720
170
170
200
22.0
S
u
EB-L2-24V
24
16.8
8.4
2,850
2,850
680
680
202
44.0
S
u
EB-L2-48V
48
33.6
7.4
6,500
6,500
1,250
1,250
355
65.0
DIMENSIONS
General tolerance:
0.3
.012
PC board pattern (Copper-side view)
Tolerance:
0.1
.003
10
0.5
.394
0.02
12
.472
7.62
.300
1
2
3
4
5
6
12
11
10
9
8
7
3
.118
1
.039
4
.157
0.4
.016
1.4
.055
1.0
.039
5.08
.200
0.5
.020
0.5
.020
7.62
.300
28
0.5
1.102
0.02
12
.472
2.54
.100
2.54
.100
12-1.3 DIA.
.047-.051 DIA.
mm
inch
Schematic
(Bottom view)
Single side stable
Deenergized position
2a2b
3a1b
4a
1
2
3
4
5
6
12
11
10
9
8
7
-
+
1
2
3
4
5
6
12
11
10
9
8
7
-
+
1
2
3
4
5
6
12
11
10
9
8
7
-
+
2 coil latching
Diagram shows the "reset"
position when terminals 6
and 7 are energized.
Energize terminals 1 and
12 to transfer contacts.
2a2b
3a1b
4a
1
2
3
4
5
6
12
11
10
9
8
7
Set
Reset
-
+
-
+
-
Set
Reset
+
1
2
3
4
5
6
12
11
10
9
8
7
-
+
-
Set
Reset
+
1
2
3
4
5
6
12
11
10
9
8
7
-
+
ORDERING INFORMATION
S
221
REFERENCE DATA
1. Maximum switching power
2. Life curve
3. Contact reliability
Condition: 1V DC, 1mA
Detection level 10
Tasted Sample: S4EB-24V, 10pcs
100
1,000
10
0.1
1
10
Contact current, A
Contact voltage, V
DC resistive load
AC resistive load
1,000
500
100
50
30
10
0
1
2
3
4
5
Contact current, A
Life,
10
4
125 V AC
(cos
= 1.0)
250 V AC
(cos
= 1.0)
99.9
99.0
95.0
0.1
1.0
10.0
0.2
0.5
1.0
2.0
5.0
10.0
30.0
50.0
70.0
No. of operations,
10
7
m = 1.6
: 79 million time
: 51 million time
95% reliability limit:
14.6 million times
(weibul probability paper)
4.-(1) Coil temperature rise
Tested Sample: S4EB-24V, 4 Form A
4.-(2) Coil temperature rise
Tested Sample: S4EB-24V, 4 Form A
5.-(1) Operate and release time
(Single side stable type)
Tested Sample: S4EB-24V, 10pcs
4A
0A
100
0.2
0.4
0.6
0.8
1.0
1.2
90
80
70
60
50
40
30
20
10
0
Coil operating power, W
Temperature rise,
C
100
1
2
3
4
5
6
90
80
70
60
50
40
30
20
10
0
Coil operating
power, 0.2 W
Contact current, A
Temperature rise,
C
Min.
Max.
Min.
Max.
Min.
Max.
80
100
120
140
20
18
16
14
12
10
8
6
4
2
0
Coil applied voltage, %V
Operate/release time, ms
Release time (with diode)
Operate time
Release time
5.-(2) Operate time (2 coil latching type)
Tested Sample: S2EB-L2-12V
Min.
Min.
Max.
Max.
20
80
100
120
140
18
16
14
12
10
8
6
4
2
Coil applied voltage, %V
Operate/release time, ms
(with diode)
(without diode)
6. Influence of adjacent mounting
5
10
30
0
+30
5
10
30
0
+30
(1)
(2)
(3)
(1) & (3) relays
are energized
Rate of change, %
Rate of change, %
Single side stable
2 coil latching
Drop-out voltage
Pick-up voltage
Pick-up voltage
Inter-relay distance, mm
Inter-relay distance, mm
Note: When installing an S-relay near another, and there is no effect
from an external magnetic field, be sure to leave at least 10 mm
.394 inch
between relays in order to acheive the performance
listed in the catalog.
7. Thermal electromotive force
200
2
4
6
8
10
12
100
Minute
NR-H
NF relay S relay
Thermal electromotive force,
V
8. Effect from an external magnetic field
0
0
50
100
30
+30
50
100
30
+30
Rate of change, %
Rate of change, %
G
G
Pick-up voltage
Pick-up voltage
Drop-out voltage
Single side stable
2 coil latching
50
100
30
30
0
+30
50
100
0
+30
Rate of change, %
Rate of change, %
G
G
Pick-up voltage
Pick-up voltage
Drop-out voltage
Single side stable
2 coil latching
S
222
ACCESSORIES
S Relay Socket,
S-PS
Specifications
(Note: Don't insert or remove relays while in the energized condition.)
Breakdown voltage
1,500 Vrms between terminals
Insulation resistance
More than 100 M
between terminals at 500 V DC Mega
Heat resistance
150
3
C (
302
5.4
F
) for 1 hour.
Maximum continuous current
4 A
Dimensions
PC board pattern (Copper-side view)
12.4
0.6
.488
.024
18.3
0.6
.720
.024
15.5
0.6
.610
.024
3.4
0.3
.134
.012
0.4
0.1
.016
.004
1.2
0.3
.047
.012
4.85
0.3
.191
.012
5.08
0.3
.200
.012
32.4
0.6
1.276
.024
1.5
0.3
.059
.012
1.5
0.3
.059
.012
7.62
0.3
.300
.012
Terminal width: 1.3
.051
Terminal thickness: 1.2
.047
7.6
.299
5.08
.200
5.08
.200
5.08
.200
5.08
.200
5.08
.200
12-1.6 DIA. HOLE
12-.063 DIA. HOLE
mm
inch
Inserting and removing method
Inserting method: Insert the relay as
shown in Fig. 1 unit the rib of the relay
snaps into the clip of the socket.
Rib
Fig. 1
Removing method:
(1) Remove the relay straight from the
socket holding the shaded portion of the
relay as shown in Fig. 2.
Fig. 2
(2) When sockets are mounted in close
proximity, use a slotted screw driver as
shown in Fig. 3.
Fig. 3
NOTES
1. Special use of 2 coil latching types: 2
ways can be considered if 2 coil latching
types are used as 1 coil latching types.
(A) Reverse polarity is applied to the set
coil of 2 coil latching type.
(B) By shorting terminals 12 and 7, apply
plus to 1, minus to 6 at set and plus to 6,
minus to 1 at reset. Applied coil voltage
should be the same as the nominal. Oper-
ating power will be reduced to one-half.
Reset position of 2a2b type
2. Soldering operations should be accom-
plished as quick as possible; within 10
seconds at 250
C
482
F
solder tempera-
ture or 3 seconds at 350
C
662
F
. The
header portion being sealed with epoxy
resin, undue subjection to heat may
cause loss of seal. Solder should not be
permitted to remain on the header.
1
2
3
4
5
6
12
11
10
9
8
7
-
+
CAUTIONS FOR USE
Based on regulations regarding insulation distance, there is a re-
striction on same-channel load connections between terminals
No. 2, 3 and 4, 5, as well as between No. 8, 9 and 10, 11. See the
figure below for an example.
4
2
5
3
10
9
4
8
11
5
2 3
9
8
11
Between 2, 3 and 4, 5:
Between 10, 11 and 8, 9:
same channels, therefore possible
same channels, therefore possible
Between 2, 3 and 4, 5:
Between 10, 11 and 8, 9:
different channels, therefore not possible
different channels, therefore not possible
10
No good
Good
For Cautions for Use, see Relay Technical Information (Page 48 to 76).