ChipFind - документация

Электронный компонент: 100302

Скачать:  PDF   ZIP
100302
Low Power Quint 2-Input OR/NOR Gate
General Description
The 100302 is a monolithic quint 2-input OR/NOR gate with
common enable. All inputs have 50 k
pull-down resistors
and all outputs are buffered.
Features
n
43% power reduction of the 100102
n
2000V ESD protection
n
Pin/function compatible with 100102
n
Voltage compensated operating range = -4.2V to -5.7V
n
Standard Microcircuit Drawing
(SMD) 5962-9152802
Logic Symbol
Pin Names
Description
D
na
D
ne
Data Inputs
E
Enable Input
O
a
O
e
Data Outputs
O
a
O
e
Complementary Data Outputs
Truth Table
D
1X
D
2X
E
O
X
O
X
L
L
L
L
H
L
L
H
H
L
L
H
L
H
L
L
H
H
H
L
H
L
L
H
L
H
L
H
H
L
H
H
L
H
L
H
H
H
H
L
H = HIGH Voltage Level
L = LOW Voltage Level
DS100303-1
August 1998
100302
Low
Power
Quint
2-Input
OR/NOR
Gate
1998 National Semiconductor Corporation
DS100303
www.national.com
Connection Diagrams
24-Pin DIP
DS100303-2
24-Pin Quad Cerpak
DS100303-3
www.national.com
2
Absolute Maximum Ratings
(Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Above which the useful life may be impaired
Storage Temperature (T
STG
)
-65C to +150C
Maximum Junction Temperature (T
J
)
Ceramic
+175C
V
EE
Pin Potential to
Ground Pin
-7.0V to +0.5V
Input Voltage (DC)
V
EE
to +0.5V
Output Current (DC Output HIGH)
-50 mA
ESD (Note 2)
2000V
Recommended Operating
Conditions
Case Temperature (T
C
)
Military
-55C to +125C
Supply Voltage (V
EE
)
-5.7V to -4.2V
Note 1: Absolute maximum ratings are those values beyond which the de-
vice may be damaged or have its useful life impaired. Functional operation
under these conditions is not implied.
Note 2: ESD testing conforms to MIL-STD-883, Method 3015.
Military Version
DC Electrical Characteristics
V
EE
= -4.2V to -5.7V, V
CC
= V
CCA
= GND, T
C
= -55C to +125C (Note 5)
Symbol
Parameter
Min
Max
Units
T
C
Conditions
Notes
V
OH
Output HIGH Voltage
-1025
-870
mV
0C to +125C
-1085
-870
mV
-55C
V
IN
= V
IH(Max)
Loading with
(Notes 3, 4,
5)
V
OL
Output LOW Voltage
-1830 -1620
mV
0C to +125C
or V
IL
(Min)
50
to -2.0V
-1830 -1555
mV
-55C
V
OHC
Output HIGH Voltage
-1035
mV
0C to +125C
-1085
mV
-55C
V
IN
= V
IH(Max)
Loading with
(Notes 3, 4,
5)
V
OLC
Output LOW Voltage
-1610
mV
0C to +125C
or V
IL
(Min)
50
to -2.0V
-1555
mV
-55C
V
IH
Input HIGH Voltage
-1165
-870
mV
-55C to +125C
Guaranteed HIGH Signal
(Notes 3, 4,
5, 6)
for All Inputs
V
IL
Input LOW Voltage
-1830 -1475
mV
-55C to +125C
Guaranteed LOW Signal
(Notes 3, 4,
5, 6)
for All Inputs
I
IL
Input LOW Current
0.50
A
-55C to +125C
V
EE
= -4.2V
(Notes 3, 4,
5)
V
IN
= V
IH
(Max)
I
IH
Input HIGH Current
240
A
0C to +125C
V
EE
= -5.7V
(Notes 3, 4,
5)
340
A
-55C
V
IN
= V
IL(Min)
I
EE
Power Supply Current
-48
-17
mA
-55C to +125C
Inputs Open
(Notes 3, 4,
5, 6)
Note 3: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals -55C), then testing immediately
without allowing for the junction temperature to stabilize due to heat dissipation after power-up. This provides "cold start" specs which can be considered a worst case
condition at cold temperatures.
Note 4: Screen tested 100% on each device at -55C, +25C, and +125C, Subgroups 1, 2, 3, 7, and 8.
Note 5: Sample tested (Method 5005, Table I) on each manufactured lot at -55C, +25C, and +125C, Subgroups A1, 2, 3, 7, and 8.
Note 6: Guaranteed by applying specified input condition and testing V
OH
/V
OL
.
AC Electrical Characteristics
V
EE
= -4.2V to -5.7V, V
CC
= V
CCA
= GND
Symbol
Parameter
T
C
= -55C
T
C
= +25C
T
C
= +125C
Units
Conditions
Notes
Min
Max
Min
Max
Min
Max
t
PLH
Propagation Delay
0.30
1.80
0.40
1.50
0.40
1.70
ns
(Notes 7, 8,
9, 10, 11)
t
PHL
Data to Output
t
PLH
Propagation Delay
0.60
2.60
0.80
2.30
0.80
2.80
ns
Figures 1, 2
t
PHL
Enable to Output
t
TLH
Transition Time
0.30
1.20
0.30
1.20
0.30
1.20
ns
(Note 10)
t
THL
20% to 80%, 80% to 20%
Note 7: F100K 300 Series cold temperature testing is performed by temperature soaking (to guarantee junction temperature equals -55C), then testing immediately
after power-up. This provides "cold start" specs which can be considered a worst case condition at cold temperatures.
3
www.national.com
AC Electrical Characteristics
(Continued)
Note 8: Screen tested 100% on each device at +25C temperature only, Subgroup A9.
Note 9: Sample tested (Method 5005, Table I) on each manufactured lot at +25C, Subgroup A9, and at +125C and -55C temperatures, Subgroups A10 and A11.
Note 10: Not tested at +25C, +125C, and -55C temperature (design characterization data).
Note 11: The propagation delay specified is for single output switching. Delays may vary up to 100 ps with multiple outputs switching.
Test Circuitry
Switching Waveforms
DS100303-5
Notes:
V
CC
, V
CCA
= +2V, V
EE
= -2.5V
L1 and L2 = equal length 50
impedance lines
R
T
= 50
terminator internal to scope
Decoupling 0.1 F from GND to V
CC
and V
EE
All unused outputs are loaded with 50
to GND
C
L
= Fixture and stray capacitance
3 pF
FIGURE 1. AC Test Circuit
DS100303-6
FIGURE 2. Propagation Delay and Transition Times
www.national.com
4
Physical Dimensions
inches (millimeters) unless otherwise noted
24-Lead Ceramic Dual-In-Line Package (0.400" Wide) (D)
NS Package Number J24E
24-Lead Quad Cerpak (F)
NS Package Number W24B
5
www.national.com