ChipFind - документация

Электронный компонент: E2C-G4

Скачать:  PDF   ZIP

Document Outline

E2C
E2C
2
Size
1/16 DIN
Miniature
Applicable
All models
E2C-CR8A, E2C-CR8B, E2C-X1A,
E2C-CR5B
sensors
E2C-C1A, E2C-X1R5A
Supply
90 to 264 VAC,
10 to 30 VDC
10 to 30 VDC
voltage
50/60 Hz
Output type
Transistor
Open collector
NPN
PNP
NPN
PNP
and relay
NPN and PNP
Part number
E2C-AK4A
E2C-AM4A
E2C-GE4A
E2C-GF4A
E2C-GE4B
E2C-GF4B
Sensor type
Shielded
Size
2.0 mm dia.
3.5 mm dia.
3.8 mm dia.
M5
5.4 mm dia.
Nominal detecting distance
0.5 mm (0.02 in)
0.8 mm (0.03 in)
0.8 mm (0.03 in)
1 mm (0.04 in)
1 mm (0.04 in)
Part number
E2C-CR5B
E2C-CR8A
E2C-CR8B
E2C-X1A
E2C-C1A
Miniature Inductive Prox
E2C
Sensor type
Shielded
Unshielded
Size
M8
M12
M18
M30
40 mm dia.
Nominal detecting distance
1.5 mm (0.06 in)
2 mm (0.08 in)
5 mm (0.20 in)
10 mm (0.39 in)
20 mm (0.79 in)
Part number
E2C-X1R5A
E2C-X2A
E2C-X5A
E2C-X10A
E2C-C20MA
s
AMPLIFIERS
Socket-Mount Types
Standard Sizes
s
SENSORS
Miniature Sizes
s
Separate amplifier allows sensor to fit in
space-confined sites, providing easy
access for monitoring and remote
adjustments
s
Detecting distance and differential travel
can be adjusted to meet specific
application requirements
s
Adjustable differential travel to set
switching trigger point available on
some amplifiers
Cylindrical Inductive Sensors
with Separate Amplifiers Provide
Variable Detecting Capabilities
Ordering Information
3
E2C
E2C
s
AMPLIFIERS
Track-Mount Types
Size
Prewired
Screw terminal
Applicable sensors
E2C-CR8A, E2C-X1A, E2C-C1A
E2C-CR8A, E2C-X1A,
E2C-X1R5A, E2C-X2A
E2C-C1A, E2C-X1R5A
Supply voltage
10 to 30 VDC,
Output type
NPN with alarm output
Open collector NPN and PNP
Part number
E2C-JC4AP
E2C-WH4AF
Description
Part number
Fits M5 size sensors (supplied with each sensor)
M5-MHWS
Fits M8 size sensors (supplied with each sensor)
M8-MHWS
Fits M12 size sensors (supplied with each sensor)
M12-MHWS
Fits M18 size sensors (supplied with each sensor)
M18-MHWS
Fits M30 size sensors (supplied with each sensor)
M30-MHWS
Mounting hardware
includes one
pair of metal
nuts and washers
s
REPLACEMENT PARTS
Description
Part number
Mounting brackets
Fits 3.5 mm and 3.8 mm dia. unthreaded sensor
Y92E-F3R5
Fits M8 size threaded sensor
Y92E-B8
Fits M12 size threaded sensor
Y92E-B12
Fits M18 size threaded sensor
Y92E-B18
Fits M30 size threaded sensor
Y92E-B30
Sockets for
E2C-AK4A
Bottom surface or track mounting, top screw terminals
P2CF-11
Panel mounting, bottom solder terminal
PL11
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3G-11
E2C-AM4A
Bottom surface or track mounting, top screw terminals
P2CF-08
Panel mounting, bottom solder terminals
PL08
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals P3G-08
E2C-G
4
Bottom surface or track mounting, top screw terminals
PYF08A-E
Panel mounting, bottom solder terminals
PY08
Bottom surface mounting, bottom screw terminals
PYF08M
Panel mounting adapters
Fits behind panel; ideal for side by side installation.
Y92F-30
for E2C-A
4A amplifiers
Use P2CF-
sockets.
Installs through panel front; amplifier face fits bezel, rear of amplifier clips
Y92F-70
to adapter. Use P3G-
sockets. Charcoal gray.
Protective covers
Hard plastic cover; not for use with Y92F-70 panel adapter
Y92A-48
Soft plastic cover; not for use with Y92F-70 panel adapter
Y92A-48D
Mounting track
DIN rail, 50 cm (1.64 ft) length
PFP-50N
DIN rail, 1 m (3.28 ft) length
PFP-100N
End plate
PFP-M
Spacer
PFP-S
for sensors
amplifiers
amplifier
amplifier
amplifiers
for E2C-A
4A amplifiers
s
ACCESSORIES
E2C
E2C
4
Specifications
Part number
E2C-CR5B
E2C-CR8A
E2C-CR8B
E2C-X1A
E2C-C1A
Sensor type
Inductive
Body
Size
2.0 mm dia.
3.5 mm dia.
3.8 mm dia.
M5
5.4 mm dia.
Type
Shielded
Required amplifier
E2C-AK4A,
E2C-AK4A, E2C-AM4A, E2C-GE4A,
E2C-AM4A,
E2C-GF4A, E2C-JC4AP or E2C-WH4AF
E2C-GE4B or
E2C-GF4B
Detectable object type
Metallic objects
0 to 0.5 mm
0 to 0.8 mm
0 to 1.0 mm
(0 to 0.02 in)
(0 to 0.03 in)
(0 to 0.04 in)
Usable setting distance at
0 to 0.7 mm
0 to 1.2 mm
0 to 1.5 mm
0
to 40
C (with standard target) (0 to 0.028 in)
(0 to 0.047 in)
(0 to 0.059 in)
Standard target size
5 x 5 x 1 mm
(mild steel, L x W x H)
(0.20 x 0.20 x 0.04 in)
Differential travel
See "Differential Travel" tables
Response frequency
1 kHz
Materials
Housing
304 stainless steel
Nickel-plated brass
Sensing face
ABS
Cable sheath
Polyethylene
Mounting
--
Optional mounting strap
Two lock washers
--
Y92E-F3R5, order separately
and M5 nuts included
Connections
Prewired
Two-conductor cable, 3 m (9.8 ft) length
Weight with cable
10 g (0.4 oz.)
40 g (1.4 oz.)
45 g (1.6 oz.)
UL
--
NEMA
1,2
1, 3, 4, 6, 12, 13
IEC 144
IP64
IP67
Approvals
UL
--
CSA
--
Ambient operating temperature
-25
to 70
C (-13
to 158
F)
Vibration
10 to 55 Hz, 1.5 mm (0.06 in) double amplitude, 2 hours each, X and Y directions
Shock
50 G's, 3 times each, X and Y directions
Usable setting distance at
ambient (with standard target)
Enclosure
ratings
s
MINIATURE SENSORS
5
E2C
E2C
Part number
E2C-X1R5A
E2C-X2A
E2C-X5A
E2C-X10A
E2C-C20MA
Sensor type
Inductive
Body
Size
M8
M12
M18
M30
40 mm dia.
Type
Shielded
Unshielded
Required amplifier
E2C-JC4AP, E2C-AK4A or E2C-AM4A
E2C-AK4A or E2C-AM4A
Detectable object type
Metallic objects
0 to 1.5 mm
0 to 2 mm
0 to 5 mm
0 to 10 mm
0 to 20 mm
(0 to 0.06 in)
(0 to 0.08 in)
(0 to 0.20 in)
(0 to 0.39 in)
(0 to 0.79 in)
Usable setting distance
0 to 2 mm
0 to 2.5 mm
0 to 7 mm
0 to 15 mm
0 to 28 mm
0
to 40
C (with standard target) (0 to 0.079 in)
(0 to 0.098 in)
(0 to 0.276 in)
(0 to 0.591 in)
(0 to 1.102 in)
Standard target size
8 x 8 x 1 mm
12 x 12 x 1 mm
18 x 18 x 1 mm
30 x 30 x 1 mm
50 x 50 x 1 mm
(mild steel, L x W x H)
(0.32 x 0.32
(0.47 x 0.47
(0.71 x 0.71
(1.18 x 1.18
(1.97 x 1.97
x 0.04 in)
x 0.04 in)
x 0.04 in)
x 0.04 in)
x 0.04 in)
Differential travel
See "Differential Travel" tables
Response frequency
800 Hz
350 Hz
100 Hz
50 Hz
Materials
Housing
Nickel-plated brass
Sensing face
ABS
Cable sheath
Polyethylene
Mounting
Two lock washers
Two lock washers
Two lock washers
Two lock washers
--
and M8 nuts
and M12 nuts
and M18 nuts
and M30 nuts
included. Bracket
included. Bracket
included. Bracket
included. Bracket
Y92E-B8 optional.
Y92E-B12 optional.
Y92E-B18 optional.
Y92E-B30 optional.
Connections
Prewired
Two-conductor cable, 3 m (9.8 ft) length
Weight with cable
50 g (1.8 oz.)
60 g (2.1 oz.)
140 g (4.9 oz.)
270 g (9.5 oz.)
300 g (10.6 oz.)
UL
--
NEMA
1, 3, 4, 6, 12, 13
IEC 144
IP67
Approvals
UL
--
CSA
--
Ambient operating temperature
-25
to 70
C (-13
to 158
F)
Vibration
10 to 55 Hz, 1.5 mm (0.06 in) double amplitude, 2 hours each, X and Y directions
Shock
50 G's, 3 times each, X and Y directions
Usable setting distance at
ambient (with standard target)
s
STANDARD SIZE SENSORS
Enclosure
ratings
E2C
E2C
6
s
AMPLIFIERS
Socket-Mount Type
Part number
E2C-AK4A
E2C-AM4A
E2C-GE4A
E2C-GF4A
E2C-GE4B
E2C-GF4B
Supply voltage
90 to 264 VAC,
10 to 30 VDC
50/60 Hz
Current consumption
55 mA max.
25 mA max.
Differential travel
See "Differential Travel" tables
Control Relay
Type
SPDT
--
Max. load
2 A, 250 VAC
--
(p.f. = 1)
Min. load
1 mA, 5 VDC
--
DC
Type
Transistor,
One NPN open
NPN open
PNP open
NPN open
PNP open
solid-
SPST
collector, one
collector with
collector with
collector with
collector with
state
PNP open
pull-up
pull-down
pull-up
pull-down
collector
Max. load
50 mA, 40 VDC
200 mA
100 mA
Max. on-state
2 VDC
1.5 VDC
voltage drop
Indicators
Output Operation (red LED) and
Output Operation (red LED)
Output Stability (red LED)
Materials
Case
Plastic
Mounting
Requires
Requires
Requires PYF08A-E, PY08 or PYF08M socket
P2CF-11,
P2CF-08,
(not included). Order separately from Accessories.
PL11 or P3G-11
PL08 or P3G-08
socket (not
socket (not
included). Order
included). Order
separately from
separately from
Accessories.
Accessories.
Connections
Plated steel screw terminals or solder terminals, refer to sockets in Accessories section.
Weight (not including socket)
250 g (8.8 oz.)
140 g (4.9 oz.)
20 g (0.7 oz.)
Enclosure
UL
--
NEMA
1
IEC 144
IP 40
Approvals
UL
--
CSA
--
Ambient operating temperature
-10
to 55
C (14
to 131
F)
Vibration
10 to 25 Hz, 2 mm (0.08 in) double amplitude, 2 hours each, X and Y directions
Shock
10 G's, 3 times each, X and Y directions
output