ChipFind - документация

Электронный компонент: E2F-X2Y1

Скачать:  PDF   ZIP

Document Outline

E2F
E2F
2
Short Length, Shielded Sensors With
Threaded Plastic Body
s
Rugged, watertight plastic housing offers
good chemical resistance and with-
stands washdown
s
Wide operating voltages: 10 to 30 VDC
and 20 to 264 VAC
s
Operation indicator on all models
s
Short-circuit protection available on all
DC and some AC models
Ordering Information
Plastic Cylindrical Inductive Prox
E2F
s
DC THREE-WIRE PREWIRED MODELS
s
AC TWO-WIRE PREWIRED MODELS
Type
Size
Sensing distance
Part number
NO
NC
Shielded
M8
1.5 mm
NPN
E2F-X1R5E1
E2F-X1R5E2
PNP
E2F-X1R5F1
E2F-X1R5F2
M12
2 mm
NPN
E2F-X2E1
E2F-X2E2
PNP
E2F-X2F1
E2F-X2F2
M18
5 mm
NPN
E2F-X5E1
E2F-X5E2
PNP
E2F-X5F1
E2F-X5F2
M30
10 mm
NPN
E2F-X10E1
E2F-X10E2
PNP
E2F-X10F1
E2F-X10F2
Type
Size
Sensing distance
Part number
NO
NC
Shielded
M8
1.5 mm
E2F-X1R5Y1
E2F-X1R5Y2
M12
2 mm
E2F-X2Y1
E2F-X2Y2
M18
5 mm
E2F-X5Y1-US
E2F-X5Y2-US
M30
10 mm
E2F-X10Y1-US
E2F-X10Y2-US
Without Short-CIrcuit Protection
Type
Size
Sensing distance
Part number
NO
NC
Shielded
M18
5 mm
E2F-X5Y1-53-US
E2F-X5Y2-53-US
M30
10 mm
E2F-X10Y1-53-US
E2F-X10Y2-53-US
With Short-CIrcuit Protection
Output
configuration
E2F
E2F
3
Mounting hardware:
one pair of plastic nuts
Description
Part number
Mounting brackets
Fits M8 size sensors
Y92E-B8
Fits M12 size sensors
Y92E-B12
Fits M18 size sensors
Y92E-B18
Fits M30 size sensors
Y92E-B30
s
ACCESSORIES
Description
Part number
Fits M8 size sensors (supplied with each sensor)
M8-PHWS
Fits M12 size sensors (supplied with each sensor)
M12-PHWS
Fits M18 size sensors (supplied with each sensor)
M18-PHWS
Fits M30 size sensors (supplied with each sensor)
M30-PHWS
s
REPLACEMENT PARTS
E2F
E2F
4
Specifications
s
DC 3-WIRE MODELS
Part number
E2F-X1R5
E2F-X2
E2F-X5
E2F-X10
Sensor Type
Inductive
Body
Size
M8
M12
M18
M30
Type
Shielded
Supply voltage
10 to 30 VDC
Current consumption
17 mA max.
Detectable object type
Metallic objects
Effective maximum detecting
1.5 mm (0.06 in)
2 mm (0.08 in)
5 mm (0.20 in)
10 mm (0.39 in)
distance (with standard target)
15%
10%
10%
10%
Usable detecting range
0 to 1.2 mm
0 to 1.6 mm
0 to 4 mm
0 to 8 mm
(with standard target)
(0 to 0.05 in)
(0 to 0.06 in)
(0 to 0.16 in)
(0 to 0.31 in)
Standard target size
8 x 8 x 1 mm
12 x 12 x 1 mm
18 x 18 x 1 mm
30 x 30 x 1 mm
(mild steel, L x W x H)
(0.31 x 0.31 x 0.04 in)
(0.47 x 0.47 x 0.04 in)
(0.71 x 0.71 x 0.04 in)
(1.18 x 1.18 x 0.04 in)
Differential travel
10% max. of effective max. detecting distance
Type
NPN-NO open collector with pull-up (E2F-X
E1)
NPN-NC open collector with pull-up (E2F-X
E2)
PNP-NO open collector with pull-down (E2F-X
F1)
PNP-NC open collector with pull-down (E2F-X
F2)
Max. load
200 mA
Max. on-state
2 VDC
voltage drop
Response frequency
2 Hz
1.5 kHz
600 Hz
400 Hz
Ouput short-
Provided; automatic resetting type
circuit
DC power
Provided
supply reverse
polarity
Weld field
Not provided
immunity
RFI immunity
Not provided
Indicators
Target Present (red LED)
Materials
Housing
Plastic
Sensing face
Plastic
Cable sheath
Plastic
Mounting
Two plastic M8 nuts
Two plastic M12 nuts
Two plastic M18 nuts
Two plastic M30 nuts
included. Bracket
included. Bracket
included. Bracket
included. Bracket
Y92E-B8 optional.
Y92E-B12 optional.
Y92E-B18 optional.
Y92E-B30 optional.
Connections
Prewired
3-conductor cable, 2 m (6.56 ft) length
Weight with cable
Approx. 40 g
Approx. 50 g
Approx. 130 g
Approx. 170 g
(1.4 oz)
(1.8 oz)
(4.6 oz)
(6.0 oz)
UL
--
NEMA
1, 3, 4, 6, 12, 13
IEC 144
IP68
Approvals
UL
--
CSA
--
Ambient operating temperature
-25
C to 70
C (-13
to 158
F)
Vibration
10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Shock
Approx. 100 G
DC
solid-
state
Control
output
Circuit
protection
Enclosure
ratings
E2F
E2F
5
s
AC 2-WIRE MODELS
Part number
E2E2F-X1R5Y
E2F-X2Y
E2F-X5Y -US
E2F-X10Y -US
E2F-X5Y -53-US
E2F-X10Y -53-US
Sensor Type
Inductive
Body
Size
M8
M12
M18
M30
Type
Shielded
Supply voltage
20 to 264 VDC, 50/60 Hz
20 to 264 VAC, 50/60 Hz (E2F-X
Y -US)
90 to 140 VAC, 50/60 Hz (E2F-X
Y -53-US)
Current consumption
5 mA max.
Detectable object type
Metallic objects
Effective maximum detecting
1.5 mm (0.06 in)
2 mm (0.08 in)
5 mm (0.20 in)
10 mm (0.39 in)
distance (with standard target)
15%
10%
10%
10%
Usable detecting range
0 to 1.2 mm
0 to 1.6 mm
0 to 4 mm
0 to 8 mm
(with standard target)
(0 to 0.05 in)
(0 to 0.06 in)
(0 to 0.16 in)
(0 to 0.31 in)
Standard target size
8 x 8 x 1 mm
12 x 12 x 1 mm
18 x 18 x 1 mm
30 x 30 x 1 mm
(mild steel, L x W x H)
(0.31 x 0.31 x 0.04 in)
(0.47 x 0.47 x 0.04 in)
(0.71 x 0.71 x 0.04 in)
(1.18 x 1.18 x 0.04 in)
Differential travel
10% max. of effective max. detecting distance
Type
SCR-NO (E2F-X
Y1-
-
)
SCR-NC (E2F-X
Y2-
-
)
Max. load
100 mA
300 mA for E2F-X
Y -US and
E2F-X
Y -53-US at -25
C to 70
C
(-13
F to 158
F)
500 mA for E2F-X
Y -US at -25
C to 55
C
(-13
F to 131
F)
Min. load
5 mA
Max. off-state
1.7 mA at 200 VAC
1.7 mA at 200 VAC (E2F-X
Y -US)
leakage current
1.5 mA at 200 VAC (E2F-X
Y -53-US)
Max. on-state
See "Residual Load Voltage Characteristics" graph in
Engineering Data.
voltage drop
Response frequency
25 Hz
Ouput short-
Not provided
Provided on E2F-X
Y -53-US types only;
circuit
manual resetting type
Weld field
Not provided
immunity
RFI immunity
Not provided
Indicators
Output Operation (red LED)
Materials
Housing
Polyarylate
Sensing face
Polyarylate
Cable sheath
Polyvinal Chloride
Mounting
Two plastic M8 nuts
Two plastic M12 nuts
Two plastic M18 nuts
Two plastic M30 nuts
included. Bracket
included. Bracket
included. Bracket
included. Bracket
Y92E-B8 optional.
Y92E-B12 optional.
Y92E-B18 optional.
Y92E-B30 optional.
Connections
Prewired
2-conductor cable, 2 m (6.56 ft) length
Weight with cable
Approx. 40 g
Approx. 50 g
Approx. 130 g
Approx. 170 g
(1.4 oz)
(1.8 oz)
(4.6 oz)
(6.0 oz)
UL
--
1
NEMA
1, 3, 4, 6, 12, 13
IEC 144
IP68
Approvals
UL
--
Recognized, File number E76675
CSA
--
Certified, FIle number LR45951
Ambient operating temperature
-25
C to 70
C (-13
to 158
F)
Vibration
10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Shock
Approx. 100 G
AC
solid-
state
Control
output
Circuit
protection
Enclosure
ratings
E2F
E2F
6
s
OUTPUT CIRCUIT DIAGRAM AND TIMING CHARTS
Operation
DC 3-Wire Models
AC 2-Wire Models
With Short-Circuit Protection
E2F
E2F
7
Engineering Data
Operating Range
Detecting Distance vs. Size and Material of Target
Shielded M8 and M12 Size Sensors
E2F-X1R5
, E2F-X2
Shielded M18 and M30 Size Sensors
E2F-X5
, E2F-X10
Shielded M8 and M12 Size Sensors
E2F-X1R5
, E2F-X2
Shielded M18 and M30 Size Sensors
E2F-X5
, E2F-X10
Note:
If the target is a nonferrous metal, the operating distance of the proximity sensor decreases. However, with a piece of foil measuring
about 0.01 mm (0.0004 in) in thickness, the detecting distance is equivalent to that with a ferrous metal. Note that the proximity
sensor cannot detect extremely thin evaporated films and non-conductive targets.
E2F
E2F
8
Residual Load Voltage Characteristics
Leakage Current Characteristics
E2F
E2F
9
AC-2-Wire Models
Dimensions
Unit: mm (inch)
DC 3-Wire Models
s
SENSORS
E2F
E2F
10
AC Shielded M18 Size without
short-circuit protection
E2F-X5Y -US
AC Shielded M18 Size with
short-circuit protection
E2F-X5Y -53-US
s
OPTIONAL MOUNTING BRACKETS
Drawing dimensions
A
B
C
D
E
F
Y92E-B8
18
0.2
10
18
8
28
M4 x 20
E2F-X1R5E(F)(Y)
(0.71
0.01)
(0.39)
(0.71)
(0.31)
(1.10)
bolt
max.
dia.
max.
Y92E-B12 24
0.2
12.5
20
12
37
M4 x 25
E2F-X2E(F)(Y)
(0.94
0.01)
(0.49)
(0.79)
(0.47)
(1.46)
bolt
max.
dia.
max.
Y92E-B18 32
0.2
17
30
18
47
M5 x 32
E2F-X5E(F)(Y) -US,
(1.26
0.01)
(0.67)
(1.18)
(0.71)
(1.85)
bolt
E2F-X5Y -53-US
max.
dia.
max.
Y92E-B30 45
0.2
17
50
30
60
M5 x 50
E2F-X10E(F)(Y) -US,
(1.77
0.01)
(0.67)
(1.97)
(1.18)
(2.36)
bolt
E2F-X10Y -53-US
max.
dia.
max.
Part
number
Applicable sensor
models
E2F
E2F
Precautions
s
TIGHTENING FORCE
Do not exceed the torque listed in the
table provided when tightening the
mounting nuts.
Part number
Maximum torque
kg-cm
in-lbs
E2F-X1R5
8
6.93
E2F-X2
8
6.93
E2F-X5
-(53)-US
20
17.32
E2F-X10
-(53)-US 20
17.32
s
EFFECTS OF SURROUNDING METALS
When mounting a proximity sensor flush with a metallic
panel, be sure to provide a minimum distance as shown
in the table below. This prevents the sensor from being
effected by metallic objects other than the target.
Sensor model
E2F-X1R5
E2F-X2
E2F-X5
E2F-X10
mm
inch
mm
inch
mm
inch
mm
inch
l
0
0
0
0
0
0
0
0
d (dia.)
8
0.31
12
0.47
18
0.71
30
1.18
D
0
0
0
0
0
0
0
0
m
4.5
0.18
8
0.31
20
0.79
40
1.57
Drawing
dimension
s
MUTUAL INTERFERENCE
To prevent mutual interference between two sensors, be
sure to space the two sensors at a distance greater than
that shown in the table below.
l
m
D
d
Sensor model
E2F-X1R5
E2F-X2
E2F-X5
E2F-X10
mm
inch
mm
inch
mm
inch
mm
inch
A
20
0.79
30
1.18
50
1.97
100
3.94
B
15
0.59
20
0.79
35
1.38
70
2.76
Drawing
dimension
A
B
OMRON ELECTRONICS LLC
OMRON CANADA, INC.
One East Commerce Drive
885 Milner Avenue
Schaumburg, IL 60173
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. CEDSAX4
11/01
Specifications subject to change without notice.
Printed in the U.S.A.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci