ChipFind - документация

Электронный компонент: E2R-A01E2R-A01

Скачать:  PDF   ZIP

Document Outline

E2R-A01
Compact Low Profile Inductive Proximity
Sensor with 5 mm Sensing Distance
Non-contact sensing assures accurate
detection regardless of target's color or
surface texture
Fast response time of 0.2 milliseconds
(5 kHz)
High output current of 100 mA
Enclosure rating: IEC144 IP50
Easy to mount package (6 mm high)
Ordering Information
Sensor
Connector
Application
Positioning a workpiece with sensor embedded in a conveyor system
Sensing head
Sensing distance
Output configuration
Part number
Non-shielded
5 mm
NPN, normally open
E2R-A01
Appearance
Cable length
Part number
1 m
E22-01
2
E2R-A01
E2R-A01
Specifications
Ratings/Characteristics
Note:
1. Refers to the distance from the detecting surface to the passing position of the detectable object which permits positive detection
even when the sensing detecting surface is decreased due to temperature or voltage fluctuation.
2. The response frequencies for DC switching are average values measured on condition that the distance between each sensing
object is twice as large as the size of the standard object and the sensing distance set is half of the maximum sensing distance.
3. Refers to a change in detecting distance when the ambient operating temperature changes within Omron's specified range and
is expressed as the rate of variation (in percentage) with the detecting distance at the rated voltage taken as 100%.
4. Refers to a change in detecting distance when the supply voltage changes within a permissible range and is expressed as the
rate of variation (in percentage) with the detecting distance at the rated voltage taken as 100%.
Engineering Data
Supply voltage (operating voltage)
12 to 24 VDC
+15%
/
-10%
, ripple (p-p): 10% max.
Current consumption
8 mA
Detectable object
Ferrous metals (refer to "Engineering Data" for non-ferrous metals)
Sensing distance
5 mm
15%
Setting distance (standard object) (see note 1) 0 to 3.4 mm (iron, 18 x 18 x 1 mm)
Differential travel
10% of max. sensing distance
Response frequency (see note 2)
5 kHz min.
Operation
Output transistor ON when sensing object
Control output
NPN open collector, 100 mA max.
Indicators
Operation indicator (red LED)
Ambient temperature
Operating: -10 to 55C (14 to 131F) with no freezing
Ambient humidity
Operating: 35% to 85% with no condensation
Temperature influence (see note 3)
20% max of sensing distance within a temperature range of -10 to 55C (14 to 131F)
based on the sensing distance at a temperature of 23C (73.4F)
Voltage influence (see note 4)
2.5% max. of sensing distance within a range of 10% of rated voltage
Residual voltage
1.0 V max. (under load current of 100 mA with cable length of 1 m)
Insulation resistance
50 M
min. (at 500 VDC) between current carrying parts and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between current carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each in X,Y and Z directions
Shock resistance
Destruction: 500 m/s2 (approx. 50G) for 3 times each in X, Y and Z directions
Enclosure rating
IEC144 IP50
Weight
Approx. 5.5 g
Material
Sensing Surface: PBT resin
Rear cover: ABS resin
3
E2R-A01
E2R-A01
Operation
Output Circuit Diagram
Timing Chart
Dimensions
Unit: mm (inch)
E2R-A01
E22-01
4
E2R-A01
E2R-A01
Precautions
Effects of Surrounding Metal
If there is any metal near the sensor, the metal may effect the per-
formance of the E2R or the temperature of the metal may effect
the sensing distance of the E2R. Make sure that the clearances
given in the following illustrations are maintained for accurate
sensing operation.
Mutual Interference
When installing two or more E2R units face to face or side by
side, make sure that the minimum distances given in the following
illustration is maintained.
Handling and Connections
The E2R incorporates a connector. Do not solder connector pins
to lead wires. Use the E22-01 Connector or Molex connector
(housing 010308033 and terminal 008700057) or Japan Molex
connector (housing 5209-03 and terminal 5103).
Do not impose external force on the terminal as shown in the fol-
lowing illustration or else the terminal may be damaged.
Do not connect or disconnect the connector with the E2R turned
on as the E2R may be damaged.
Power Supply
When using a standard switching regulator with the E2R, ground
the frame ground (FG) and ground (G) terminals of the switching
regulator for stable operation.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
Cat. No. GC A
PMS-1
Printed in USA
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
416-286-6465
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
1-800-55-OMRON
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci
9/02 Specifications subject to change without notice