J
SENSORS
Type
Supply voltage
Output
Connection Sensing range
Standard target
Timer function
Part number
Polarized
10-30 VDC
NPN/PNP
Pre-leaded
500 mm to 10 m
80 mm dia.
----
E3G-R13
Polarized
retroreflective
10 30 VDC
NPN/PNP
Connector
500 mm to 10 m
with E39-R2
reflector
80 mm dia.
E3G-R17
12-240 VDC,
Relay
Terminal
reflector
(included)
E3G-MR19-US
12 240 VDC,
24-240 VAC
Relay
Terminal
block
(included)
ON or OFF
delay 0--5s,
adjustable
E3G-MR19T-US
Diffuse
10-30 VDC
NPN/PNP
Pre-leaded
200 mm to 2 m
300 x 300 mm
----
E3G-L73
Diffuse
reflective
10 30 VDC
NPN/PNP
Connector
200 mm to 2 m
300 x 300 mm
Kodak 90%
white card
E3G-L77
12-240 VDC,
Relay
Terminal
white card
E3G-ML79-US
12 240 VDC,
24-240 VAC
Relay
Terminal
block
ON or OFF
delay 0--5s,
adjustable
E3G-ML79T-US
J
CONNECTOR CORDSETS
Connector Cables
Shape
Length
Conductors
Part number
Straight
2 m
Three
XS2F-D421-DC0-A
5 m
XS2F-D421-GC0-A
Right angle
2 m
XS2F-D422-DC0-A
5 m
XS2F-D422-GC0-A
E3G
E3G
3
J
ACCESSORIES (ORDER SEPARATELY)
Reflectors
Shape
Sensing distance (typical)
Remarks
Part number
500 mm to 10 m
Included with E3G-Rjj and
E3G-MRjj
E39-R2
100 mm to 6 m
---
E39-R1
Terminal Protection Cover for Side-pullout Cable (required when side-exit is desired for cable)
Shape
Applicable model
Remarks
Part number
E3G-MR19 (T), ML79 (T)
Provided with rubber bushing and cap
for pullout prevention in vertical
direction
E39-L129
Mounting Brackets (not included, order separately)
Shape
Applicable model
Remarks
Part number
Shape
Pre-leaded and connector models
E3G-R1j
E3G-L7j
---
E39-L131
Rear-mounting use
E39-L132
Terminal block models
E3G-MR19 (T)
E3G-ML79 (T)
Cable pulled out in the downward
direction
E39-L135
E3G-MR19 (T)
E3G-ML79 (T)
---
E39-L136
E3G
E3G
4
Specifications
J
RATINGS/CHARACTERISTICS
Sensing method
Retroreflective (polarized)
Diffuse
Part number
E3G-R13
E3G-R17
E3G-MR19 E3G-MR19T E3G-L73
E3G-L77
E3G-ML79 E3G-ML79T
Sensing distance
0.5 to 10 m (1.64 to 32.8 ft) using E39-R2
0.2 to 2 m (0.66 to 6.56 ft)
Setting distance
---
0.5 to 2 m (1.64 to 6.56 ft)
Standard sensing
object
Opaque: 80 dia. min.
Kodak 90% white card 300 x 300 mm
Hysteresis (typical)
---
10% of setting distance
Directional angle
Sensor: 1 to 5
Reflector: 40 min.
---
Reflectivity
characteristics
(black/white error)
---
10% max. (at 1-m sensing distance)
Light source
(wavelength)
Red LED (700 nm)
Infrared LED (860 nm)
Spot size
---
70 dia. max. at 1-m sensing distance
Supply voltage
10 to 30 VDC including
10% (p-p) ripple
12 to 240 VDC 10%
including 10% (p-p) max.
ripple
24 to 240 VAC 10% at
50/60 Hz
10 to 30 VDC including
10% (p-p) ripple
12 to 240 VDC 10%
including 10% (p-p) max.
ripple
24 to 240 VAC 10% at
50/60 Hz
Current consumption
50 mA max.
2 W max.
60 mA max.
2 W max.
Output
30 VDC max.
Load current:
100 mA max. Residual
voltage: NPN output:
1.2 V max. PNP output:
2.0 V max.
Open collector output
(NPN/PNP selectable)
Relay output: SPDT,
3 A (cos = 1) max. at
250 VAC or 3 A max. at
30 VDC
Load power supply
voltage: 30 VDC max.
Load current:
100 mA max.
Residual voltage: NPN
output: 1.2 V max. PNP
output: 2.0 V max.
Open collector output
(NPN/PNP selectable)
Relay output: SPDT,
3 A (cos = 1) max. at
250 VAC or 3 A max. at
30 VDC
Operation mode
Light-ON/Dark-ON switch selectable
Life expectancy
(relay output)
Mechanical:50,000,000 operations min. (switching frequency: 18,000 operations/h)
Electrical: 100,000 operations min. (switching frequency: 1,800 operations/h)
Circuit protection
Protection from reversed
power supply connection,
load short-circuit, and
mutual interference
Protection from mutual
interference
Protection from reversed
power supply connection,
load short-circuit, and
mutual interference
Protection from mutual
interference
(This table continues on the next page.)
E3G
E3G
5
Specifications Table
-- continued from previous page
Sensing method
Retroreflective (polarized)
Diffuse
Part number
E3G-R13
E3G-R17
E3G-MR19 E3G-MR19T E3G-L73
E3G-L77
E3G-ML79 E3G-ML79T
Response time
1 ms
30 ms max.
5 ms
30 ms max.
Sensitivity adjustment One-turn potentiometer
Teaching (in NORMAL or ZONE mode)
Ambient illumination
(receiver side)
Incandescent lamp: 3,000 lx max.
Sunlight: 10,000 lx max.
Ambient temperature
Operating: --25C to 55C (--13 to 131F)
Storage: --30C to 70C (--22 to 158F) with no icing or condensation
Relative humidity
Operating: 35% to 85%/
Storage: 35% to 95% with no condensation
Insulation resistance
20 M min. at 500 VDC
Dielectric strength
1,000 VAC, 50/60 Hz for
1 min
2,000 VAC, 50/60 Hz for
1 min
1,000 VAC, 50/60 Hz for
1 min
2,000 VAC, 50/60 Hz for
1 min
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z axes
Shock resistance
500 m/s
2
3 times each in X, Y, and Z axes
Degree of protection
IP67
Connection method
2 m cable
M12
connector
Terminal block
2 m cable M12
connector
Terminal block
Weight
(packed state)
Approx.
150 g
Approx. 50 g Approx. 150 g
Approx. 50 g Approx. 150 g
Material
Case
PBT (polybutylene terephthalate)
Material
Lens
Acrylic (PMMA)
Mounting
bracket
Stainless steel (SUS304), order separately
Engineering Data
J
RETROREFLECTIVE MODELS, E3G-R/MR
Lateral Movement
D
i
s
t
a
n
c
e
Y
(mm)
Excess Gain
I
n
c
i
dent
out
put
ex
c
e
s
s
gai
n
ON level
Distance (m)
E39-R2 Reflector
Distance X (m)
E39-R2 Reflector
E3G
E3G
6
J
DIFFUSE MODELS, E3G-L/ML
Spot Diameter vs.
Sensing Distance
Sensing Zone in NORMAL Mode
Sensing Zone in ZONE Mode
S
p
o
t
d
i
a
m
e
t
e
r
(mm)
D
i
s
t
a
n
c
e
Y
(mm)
D
i
s
t
a
n
c
e
Y
(mm)
Horizontal
Vertical
Distance setting: 0.5, 1, and 2 m
Sensing object: White paper
300 x 300 mm
Distance (m)
Distance setting: 1 and 2 m
Sensing object: White paper
300 x 300 mm
Distance X (m)
0.5 m
1 m
2 m
Distance X (m)
0.5 m
1 m
2 m
0
0
Sensing Object Size vs.
Setting Distance
Sensing Object Angle
Characteristics
(Up and Down)
Sensing Object Angle
(Left and Right)
S
ens
i
n
g
d
i
s
t
anc
e
v
ar
i
a
t
i
on
(
%
)
Side length (one side) of
sensing object: d (mm)
Inclination angle (_)
Inclination angle (_)
(Left and Right)
Inclination
angle
Inclination angle
(Upwards and
Downwards)
S
ens
i
n
g
d
i
s
t
anc
e
(
m
)
White paper
Black paper
S
ens
i
n
g
d
i
s
t
anc
e
v
ar
i
a
t
i
on
(
%
)
Sensing object: White paper
Sensing distance: 1 m
Sensing object: White paper
Sensing distance: 1 m
Sensing object
Sensing object
2 m
1 m
0.5 m
Sensing Distance vs.
Sensing Object Material
(at 1-m Setting Distance)
Sensing Distance vs.
Sensing Object Material
(at 500-mm Setting Distance)
Close-range Characteristics
S
ens
i
n
g
d
i
s
t
anc
e
(
m
)
Material
W
h
it
e
paper
B
l
ac
k
paper
F
i
ber
boar
d
V
eneer
B
l
ac
k
r
ubber
Mi
rro
r
Material
Black
paper
(0.5 m)
White
paper
(0.5 m)
Black
paper
(2 m)
White
paper
(2 m)
Material (teaching distance m)
W
h
it
e
paper
B
l
ac
k
paper
F
i
ber
boar
d
V
eneer
B
l
ac
k
r
ubber
Mi
rro
r
S
ens
i
n
g
d
i
s
t
anc
e
(
m
)
S
e
n
s
i
n
g
d
i
s
t
a
n
c
e
(mm)
E3G
E3G
7
Operation
J
OUTPUT CIRCUITS
NPN/PNP Selectable
Part number
E3G-R13
E3G-R17
E3G-L73
E3G-L77
Output
transistor
status
Light ON
Dark ON
Light ON
Dark ON
Timing chart
Received
ON
Operation
indicator
(orange)
Output
transistor
Load
(relay)
Not received
OFF
ON
OFF
Operate
Reset
Received
ON
Operation
indicator
(orange)
Output
transistor
Load
(relay)
Not received
OFF
ON
OFF
Operate
Reset
Incident
ON
Operation
indicator
(orange)
Output
transistor
Load
(relay)
Interrupted
OFF
ON
OFF
Operate
Reset
(Between blue and black)
Incident
ON
Operation
indicator
(orange)
Output
transistor
Load
(relay)
Interrupted
OFF
ON
OFF
Operate
Reset
(Between blue and black)
Output
configuration
NPN
PNP
Output
circuit
Main
circuit
PNP output
transistor
NPN or PNP
output selector
100 mA
max.
Load
Brown
Black
Blue
Output
10 to 30 VDC
NPN output
transistor
Connector Pin Arrangement
Pin 2 is open.
0 V
Operation
indicator
Stability
indicator
Main
circuit
Orange
Green
PNP output
transistor
NPN or PNP
output selector
Load
Brown
Black
Blue
Control output
10 to 30 VDC
Note:
Set the NPN or PNP selector to PNP.
(see
note)
NPN output
transistor
100 mA
max.
Connector Pin Arrangement
Pin 2 is open.
0 V
E3G
E3G
8
Relay Output
Timer function
---
Part number
E3G-MR19
E3G-ML79
Timing chart
Received
ON
Operation
indicator
(orange)
Not received
OFF
ON
OFF
Ta
Received
ON
Operation
indicator
(orange)
Not received
OFF
ON
OFF
Ta
Mode selector
Light-ON (L/ON)
Dark-ON (D/ON)
Timer function
ON or OFF delay
0 to 5 s (adjustable)
Part number
E3G-MR19T
E3G-ML79T
Timing chart
Incident
ON
ON delay
OFF delay
OFF
ON
OFF
Interrupted
Incident
ON
ON delay
OFF delay
OFF
ON
OFF
Interrupted
Mode selector
Light-ON (L/ON)
Dark-ON (D/ON)
Output circuit
Main
circuit
24 to 240 VAC or
12 to 240 VDC
(no polarity order
restricted)
Output
Power
supply
Note: Td1, Td2: Delay time (0 to 5 s)
T
1
:
A period longer than the delay time.
T
2
:
A period shorter than the delay time.
For ON- and OFF-delay timers, Td1 and Td2 are independently variable.
J
CONNECTOR
Pin No.
Wire colors
Brown
Blue
Black
XS2F-D421-DC0-A
XS2F-D421-GC0-A
XS2F-D422-DC0-A
XS2F-D422-GC0-A
Y96E-43jDj
connector
cordsets
Classification
Wire color
Connector
pin No.
Use
DC
Brown
1
Power
supply (+V)
---
2
Not used
Blue
3
Power
supply (0 V)
Black
4
Output
E3G
E3G
9
Nomenclature
J
CONTROL PANELS
Stability indicator
(Green)
Operation indicator
(Orange)
PNP/NPN selector
Sensitivity adjuster
Retroreflective
E3G-R13 (Pre-leaded Model)
E3G-R17 (Connector Model)
L.ON/D.ON selector
ON-delay adjuster
(see note)
Sensitivity adjuster
E3G-MR19 (Terminal Block Model)
E3G-MR19T (Terminal Block Model with Timer)
OFF-delay adjuster
(see note)
Operation indicator (Orange)
Stability indicator (Green)
L.ON/D.ON selector
Note: The ON- or OFF-delay adjuster is not available with the E3G-MR19.
Stability indicator (Green)
Teaching indicator (Red and green)
Operation indicator
(Orange)
Diffuse
E3G-L73 (Pre-leaded Model)
E3G-L77 (Connector Model)
Mode selector:
TEACH, RUN (D-ON),
RUN (L.ON)
PNP/NPN selector
ON-delay adjuster
(see note)
E3G-ML79 (Terminal Block Model)
E3G-ML79T (Terminal Block Model with Timer)
OFF-delay adjuster
(see note)
Stability indicator (Green)
Teaching indicator (Red and green)
TEACH button
TEACH/RUN selector
L.ON/D.ON selector
TEACH button
Operation indicator (Orange)
Note: The ON- or OFF-delay adjuster is not available with the E3G-ML79.
NORMAL/ZONE selector
NORMAL/ZONE selector
E3G
E3G
10
Installation
J
POWER SUPPLY
A power supply with full-wave rectification can be connected to
the E3G-MR19(T).
J
WIRING
The tensile strength of the cable during operation should not
exceed the values shown below.
Part number
Tensile strength
E3G-R13, E3G-MR19(T)
50 N max.
E3G-R17
10 N max.
J
ADJUSTMENTS
Indicators
The following illustration indicates the operation levels of the
E3G.
Set the E3G so that it will work within the stable operation range.
Stable
operation
range
(see note)
Unstable
operation
range
(see note)
Operation
level x 1.2
Operation level
ON
OFF
ON
ON
OFF
OFF
ON
L. ON
D. ON
Operation indicator (orange)
Stability indicator
(green)
Stable
operation
range
(see note)
I
n
c
i
dent
lev
e
l
Operation
level x 0.8
Note: If the operation level is set to the stable operation range,
the E3G will operate with the highest reliability and without
being influenced by temperature change, voltage fluctua-
tion, dust, or setting change. If the operation level cannot
be set to the stable operation range, pay close attention to
environmental changes while operating the E3G.
J
MOUNTING DIFFUSE MODELS
Mounting Directions
Make sure that the sensing side of the Sensor is parallel with the
surface of each sensing object. Do not tilt the Sensor towards the
sensing object.
Sensing side
Surface of sensing object
If the sensing object has a glossy surface, tilt the Sensor by 5 to
10 as shown below, provided that the Sensor is not influenced
by any background objects.
Glossy object
E3G
E3G
11
If there is a mirror-like object below the Sensor, the Sensor may
not be in stable operation. Therefore, tilt the Sensor or keep the
Sensor a distance away from the mirror-like object as shown
below.
Sensing object
Mirror-like object
Make sure not to install the Sensor in the incorrect direction.
Refer to the following.
Sensing
object
Moving direction
Moving direction
Sensing
object
Sensing
object
Moving direction
Correct
Correct
Incorrect
Install the Sensor as shown in the following if each sensing
object greatly differs in color or material.
Moving direction
Moving direction
Correct
Incorrect
J
OTHERS
If a teaching data error occurs with the operation indicator
flashing due to a power failure or static noise, perform the
teaching operation of the Sensor again.
J
ADJUSTMENTS FOR DIFFUSE MODELS
Adjustment Steps
1
Install, wire, and turn ON the Sensor.
2
Perform sensitivity adjustments (teaching). Refer to Distance Setting (Teaching) below.
3
Check that the mode selector is set to RUN.
E3G
E3G
12
J
DISTANCE SETTING (TEACHING)
Select the most appropriate teaching method in reference to the following descriptions.
Application
Teaching without sensing
objects (i.e., teaching the
background).
Setting a threshold in the
middle between the
background and sensing
object for operation.
Detection of glossy objects
in front of the background.
Setting the maximum
sensing distance of the
Sensor.
Teaching
Normal one-point teaching Normal two-point teaching
Zone teaching
Maximum distance setting
(in normal mode)
Setting method
Press the TEACH button
with the background
object.
Press the TEACH button
with the background object
and with the sensing
object.
Press the TEACH button
with the background object
(conveyor, etc.).
Press the TEACH button
for longer than three
seconds.
Set threshold
Threshold (a) is set to a
distance in front of the
background of 20% of the
background distance.
Threshold (a) is set
approximately in the
middle between the
background and sensing
object.
Thresholds (a and b) are
set in the sensing distance
on condition that the
difference between these
thresholds are
approximately 10% of the
whole sensing distance.
The threshold is set so
that the stability indicator
will turn ON at
approximately 2 m if the
sensing object is white
paper.
Output ON range
The output is ON between
the Sensor and La.
The output is ON between
the Sensor and La.
The output is ON between
La and Lb.
The output is ON
whenever the sensing
object is located between
the Sensor and at a
distance of 2.2 m.
La: Distance equivalent to threshold (a)
Lb: Distance equivalent to threshold (b)
Normal One-point Teaching
Operation
Normal Two-point Teaching
Zone Teaching
Maximum Distance Setting (in Normal Mode)
1.
Set the mode selector to TEACH.
2.
Set the NORMAL/ZONE mode selector to NORMAL.
3.
Press the TEACH button with a sensing object located at the sensing
position. The teaching indicator (red) will turn ON.
4.
Move the sensing object and press the TEACH button with the back-
ground.
If the teaching is successful, the teaching indicator (green) willturn
ON.
Iftheteachingisnotsuccessful, theteaching indicator(red) willstart
to flash.
5.
If the teaching is successful, set the mode selector to RUN to complete
the teaching operation.
Set the E3G tolight- ordark-ON modewith themode selectoraccording
to the application.
If the teaching is not successful, change the set distance and object
sensing position and repeat two-point teaching from step 3.
Operation
1.
Set the mode selector to TEACH.
2.
Set the NORMAL/ZONE mode selector to ZONE.
3.
Press the TEACH button with the background.
The teaching indicator (red) will turn ON first. Then the teaching
indicator (green) will turn ON.
4.
Set the mode selector to RUN.
(Set to L-ON or D-ON mode.)
Operation
Note: Perform zone teaching with the background.
Operation
1.
Set the mode selector to TEACH.
2.
Set the NORMAL/ZONE mode selector to NORMAL.
3.
Press the TEACH button for 3 s or more.
The teaching indicator (red) will turn ON.
The teaching indicator (green) will turn ON in 3 s. This means that
teaching was successful.
4.
If the teaching is successful, set the modeselector toRUN tocomplete
the teaching operation.
(Set to L-ON or D-ON mode.)
1.
Set the mode selector to TEACH.
2.
Set the NORMAL/ZONE mode selector to NORMAL.
3.
Press the TEACH button with no sensing object
(i.e., teach the background). The teaching indicator (red) will turn ON.
4.
Set the mode selector to RUN.
(Set to L-ON or D-ON mode.)
J
ZONE MODE
Zone Teaching
J
NORMAL MODE
1. Normal One-point Teaching
E3G-L/ML
Threshold
a (La)
Threshold b (Lb)
Note: Perform normal one-point teaching with the background.
P
r
oc
edur
e
P
r
oc
edur
e
P
r
oc
edur
e
P
r
oc
edur
e
E3G-L/ML
ON
ON
ON
OFF
2. Normal Two-point Teaching
Threshold a
(La)
Background
E3G-L/ML
Threshold a
(La)
Background
Object
L-ON
D-ON
Background
ON
OFF
ON
OFF
E3G
E3G
13
J
TERMINAL BLOCK MODELS
E3G-MR
jjj, E3G-MLjjj
Wiring
The cable with an external diameter of 6 to 8 mm is
recommended.
Be sure to attach the cover with screws securely in order to
maintain the water- and dust-resistive properties of the product.
Terminal Cover
Do not tighten the terminal protection cover with wires pinched
between the Sensor and the cover in order to maintain the water-
and dust-resistive properties of the product.
Output
Power supply
Rubber bushing
Washer
Clamping nut
63 mm
33 mm
Terminal
protection
cover
Recommended Example
J
CHANGING CABLE EXIT
Procedure
1. Remove the present cover. (Item 1 below)
2. Attach the E39-L129 Terminal Protection Cover for side-pull-
out cable.
3. Remove the clamping nut, washer, and rubber bushing of the
E3G. These are used for the side-pullout cable.
4. Attach the rubber bushing and cap provided with the
E39-L129 to the E3G as replacements.
Rubber bushing
*
Cap*
Rubber bushing
Washer
E39-L129 Terminal
Protection Cover
Clamping nut
(1)
(2)
(2)
(3)
(4)
Note: *Provided with the E39-L129.
E3G
E3G
14
Dimensions
Unit: mm (inch)
J
SENSORS
E3G-R13 and E3G-L73
Pre-leaded Models
Operation indicator (orange) Operation mode selector
Stability indicator
(green)
Sensitivity
adjuster
M2.6
Two, 4.5-dia.
mounting
holes
R11
Receiver
R7
Emitter
Vinyl-insulated round cable
with three conductors, 6 dia.
(17 x 0.16 dia.); standard
length: 2 m
E3G-R17 and E3G-L77
Connector Models
Note:
All dimensions other than the
ones specified below are the
same as the corresponding di-
mensions of E3G-R13.
10.5 dia.
M12 Connector
Mounting holes
Two, M4
25
(0.98)
47.8 (1.88)
45
25
29
43
21
(0.83)
12
14
(0.55)
67.8
68.5
(2.70)
22
(0.87)
24.4
(0.96)
18.8
(0.74)
1.1
12
43
37
8
8
7
10
E3G-MR19, E3G-MR19T, E3G-ML79 and E3G-ML79T
Terminal Block Models
Two, 4.5-dia.
mountingholes
R11
Receiver
R7
Emitter
Mounting holes
Two, M4
Clamping nut 22 mm
Applicable cable: 6 to 8 dia.
29
(1.14)
12
2.1
35.95
(1.42)
6
18.8
(0.74)
22
14
84.95
(3.34)
12
84.45
16
(0.63)
37 (1.46)
68 (2.68)
74
(2.91)
44
(1.73)
74
(2.91)
37
(1.46)
Operation
mode selector
Stability indicator
(green)
Sensitivity adjuster
M2.6
OFF-delay adjuster
ON-delay adjuster
Operation indicator (orange)
1/2-14 NPT
conduit entrance
E3G
E3G
15
J
ACCESSORIES (ORDER SEPARATELY)
E39-R1
Material
Surface: Acrylic resin
Backside: ABS resin
Two, 3.5 dia.
Reflectors
E39-R2
Material
Surface: Acrylic resin
Backside: ABS resin
Four, 3.5 dia.
Terminal Protection Cover for
Side-pullout Cable
E39-L129
Note: 1. The cover is provided with a rubber
bushing and cap to prevent the cable
from being pulled out vertically.
2. Refer to page 13 for the mounting
method of the product.
Note: Supplied with E3G-Rjj, E3G-MRjj, and E3G-MRjj-US.
80.8 (3.18)
59.9
(2.36)
J
MOUNTING BRACKETS (NOT INCLUDED, ORDER SEPARATELY)
E39-L131
E39-L132
Material: Stainless steel (SUS304)
Material: Stainless steel (SUS304)
Two, R2.2
Four, R2.1
Two,
4.2 dia.
4.2 dia.
Two, R3.2
Two, R3.2
Two, R3.2
Four, R1
Two, R3.2
901
901
E3G
E3G
16
E39-L135
E39-L136
Material: Stainless steel (SUS304)
Material: Stainless steel (SUS304)
Two, R3.2
Two, R3.2
Two, 4.2 dia.
901
Two, 4.2
Four, R2.1
Fourteen,
R2.1
Two, R3.2
Two, R3.2
J
CONNECTOR CORDSETS
Straight
XS2F-D421-DC0-A (L=2 m)
XS2F-D421-GC0-A (L=5 m)
Right angle
XS2F-D422-DC0-A (L=2 m)
XS2F-D422-GC0-A (L=5 m)
6 dia.
6 dia.
14.9 dia.
5 dia.
5 dia.
45
M12
40.7
L
30
5
50
M12
45
L
30
5
50
25.3
28.3
E3G
E3G
17
Precautions
Do not ignore the following items that are essential for securing
safety during Sensor operation.
Do not use the Sensor in locations with explosive or flam-
mable gas.
Do not use the Sensor in the water or electrically conductive
solutions.
Do not disassemble, repair, or modify the product.
Make sure that the power supply specifications, such as AC
or DC, are correct.
Do not apply voltage or current exceeding the rated ranges.
Do not make mistakes in wiring, such as mistakes in polarity.
Be sure to connect the load correctly.
Do not short-circuit the load terminals.
J
DESIGNING
Load Relay Contact
If E3G is connected to an inductive load with contacts that spark
when the load is turned OFF (e.g., a contactor or valve), the
normally-closed side may be turned ON before the normally-open
side is turned OFF or vice-versa. If both normally-open output
and normally-closed output are used simultaneously, apply an
surge suppressor to the load.
Stabilization on Power-up
The Sensor needs 100 ms to be ready to operate after it is turned
ON. The devices connected to E3G wait until the Sensor is ready
to operate. If the Sensor and load are connected to separate
power supplies, be sure to turn ON the Sensor first.
Power OFF
A single pulse signal may be output from the Sensor immediately
after it is turned OFF. This will occur more frequently if a timer or
counter is connected to the Sensor and power is supplied to the
timer or counter independently. Be sure to supply power to the
timer or counter from the built-in power supply of the Sensor.
Power Supply
If a standard switching regulator is used, be sure to ground the
FG (frame ground) and G (ground) terminals, otherwise the
Sensor may malfunction due to the switching noise of the
regulator.
Repeated Cable Bending
Do not bend the sensor cable repeatedly.
High-tension Lines
Do not wire power lines or high-tension lines alongside the lines
of the Sensor in the same conduit, otherwise the Sensor may be
damaged or may malfunction due to induction. Be sure to wire
the lines of the Sensor separated from power lines or
high-tension lines or laid in an exclusive, shielded conduit.
J
WIRING
The E3G has a built-in function to protect the Sensor from load
short-circuiting. If load short-circuiting results, the output will be
turned OFF. In that case, check the wiring and turn ON the E3G
again so that the short-circuit protection circuit will be reset. This
function will operate if the output current flow is at least 2.0 times
the rated load current. If an inductive load is connected to the
E3G, make sure that the inrush current does not exceed 1.2
times the rated load current.
The cable can be extended up to a total length of 100 m, on
condition that the thickness of the wire is at least 0.3 mm.
J
MOUNTING
Mounting Conditions
If Sensors are mounted face-to-face, make sure that no optical
axes cross each other. Otherwise, mutual interference may
result.
Be sure to install the Sensor carefully so that the directional
angle range of the Sensor will not be directly exposed to
intensive light, such as sunlight, fluorescent light, or incandescent
light.
Do not strike the Photoelectric Sensor with a hammer or any
other tool during the installation of the Sensor, or the Sensor will
loose its water-resistive properties.
Use M4 screws to mount the Sensor.
When mounting the case, make sure that the tightening torque
applied to each screw does not exceed 1.2 N S m.
M12 Connector
Be sure to connect or disconnect the M12 connector after turning
OFF the Sensor.
Be sure to hold the connector cover when connecting or
disconnecting the M12 connector.
The M12 connector must be only hand-tightened.
If the M12 connector is not connected securely, the proper
degree of protection of the Sensor may not be maintained or the
connector may be disconnected due to vibration.
Water Resistance
Do not use the product in water, in rain, or outdoors.
Tighten the operation cover screws and terminal block cover
screws to a torque of 0.3 to 0.5 N S m in order to ensure water
resistivity.
J
MAINTENANCE AND INSPECTION
Cleaning
Use only water and mild detergent. Do not use harsh chemicals
or solvents.
J
OPERATING ENVIRONMENT
Do not install the E3G in locations with the following conditions.
Excessive dust.
Corrosive gases.
Directly exposed to sprays of water, oil, or chemicals.
Directly exposed to vibration or shock.
E3G E3G
Cat. No. CEDSAX4
11/01
Specifications subject to change without notice. Printed in U.S.A.
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
1-800-55-OMRON
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
416-286-6465
R
OMRON ON--LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci