171
Solid-state Relay
G3CN
PCB-mounting SSR for FA Equipment
Requiring High Reliability
Wide I/O voltage range: 3 to 28 VDC input and 75 to
264 VAC output or 3 to 28 VDC input and 3 to
52.8 VDC output.
Two load currents available: 2 A and 3 A
Flat and vertical models available for a variety of
applications.
Approved by UL and CSA.
RC
Ordering Information
Isolation
Zero cross
function
Indicator
Rated output voltage
(Applicable output load)
Rated input voltage
Model
Photocoupler
Yes
No
2 A at 100 to 240 VAC
(2 A at 75 to 264 VAC)
4 to 24 VDC
G3CN-202P-US
G3CN-202P1-US*
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
G3CN-203P-US
G3CN-203P1-US*
Phototriac
No
2 A at 100 to 240 VAC
(2 A at 75 to 264 VAC)
5, 12, 24 VDC**
G3CN-202PL-US
G3CN-202PL1-US*
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
G3CN-203PL-US
G3CN-203PL1-US*
Photocoupler
---
2 A at 4 to 48 VDC
(2 A at 3 to 52.8 VDC)
4 to 24 VDC
G3CN-DX02P-US
G3CN-DX02P1-US*
3 A at 4 to 48 VDC
(3 A at 3 to 52.8 VDC)
G3CN-DX03P-US
G3CN-DX03P1-US*
*Vertical models.
**When ordering, specify the input voltage
G3CN
G3CN
172
Specifications
Ratings
Input
Model
Rated voltage
Operating voltage
Impedance
Voltage level
Must operate
voltage
Must release
voltage
G3CN-202P(1)-US
G3CN-203P(1)-US
4 to 24 VDC
3 to 28 VDC
1.5 k
+20%
/
10%
3 VDC max.
1 VDC min.
G3CN-202PL(1)-US
G3CN 203PL(1) US
5 VDC
4 to 6 VDC
390
20%
4 VDC max.
G3C
0
( ) US
G3CN-203PL(1)-US
12 VDC
9.6 to 14.4 VDC
900
20%
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
2 k
20%
19.2 VDC max.
G3CN-DX02P(1)-US
G3CN-DX03P(1)-US
4 to 24 VDC
3 to 28 VDC
1.5 k
+20%
/
10%
3 VDC max.
Note:
The input impedance is measured at the maximum value of the operating voltage. For example, with the model rated at 4 to 24 VDC, the
input impedance is measured at 28 VDC.
Output
Model
Applicable load
Rated load voltage
Load volage range
Load current
Inrush current
Without heat sink
G3CN-202P(1)-US
G3CN-202PL(1)-US
100 to 240 VAC
75 to 264 VAC
0.1 to 2 A
30 A (60 Hz, 1 cycle)
G3CN-203P(1)-US
G3CN-203PL(1)-US
0.1 to 3 A
45 A (60 Hz, 1 cycle)
G3CN-DX02P(1)-US
4 to 48 VDC
3 to 52.8 VDC
0.1 to 2 A
12 A (10 ms)
G3CN-DX03P(1)-US
0.1 to 3 A
18 A (10 ms)
Characteristics
Item
G3CN-202P(1)/203P(1)-US
G3CN-202PL(1)/203PL(1)-US
G3CN-DX02P(1)/03P(1)-US
Operate time
1/2 of load power source cycle +
1 ms max.
1 ms max.
0.5 ms max.
Release time
1/2 of load power source cycle +
1 ms max.
1/2 of load power source cycle
+ 1 ms max.
2 ms max.
Output ON voltage drop
1.6 V (RMS) max.
1.5 V max.
Leakage current
5 mA max. (at 100 VAC)
10 mA max. (at 200 VAC)
2.5 mA max. (at 100 VAC)
5 mA max. (at 200 VAC)
5 mA max. (at 50 VDC)
Insulation resistance
100 M
min. (at 500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s
2
Ambient temperature
Operating: 30
C to 80
C (with no icing nor condensation)
Storage:
30
C to 100
C (with no icing nor condensation)
Ambient humidity
Operating: 45% to 85%
Approved standards
UL508, UL114 File No.E64562, CSA C22.2 (No.0, No.14) File No. LR35535
Weight
Approx. 25 g
G3CN
G3CN
173
Engineering Data
Load Current vs. Ambient Temperature Characteristics
G3CN-202P(1)/-202PL(1)/-DX02P(1)-US
Ambient temperature (
C)
Load current (A)
G3CN-203P(1)/-203PL(1)/-DX03P(1)-US
Load current (A)
Ambient temperature (
C)
G3CN-203P(1)/-203PL(1)-US
G3CN-DX02P(1)-US
Inrush current (A. Peak)
Energizing time (ms)
Inrush current (A. Peak)
Energizing time (ms)
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
G3CN-202P(1)/-202PL(1)-US
G3CN-DX03P(1)-US
Inrush current (A. Peak)
Inrush current (A. Peak)
Energizing time (ms)
Energizing time (ms)
G3CN
G3CN
174
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Input
voltage
Terminal Arrangement/
Internal Connections
(Bottom View)
Flat Model
G3CN-20
j
P/-20
j
PL/-DX0
j
P
Vertical Model
G3CN-20
j
P1/-20
j
PL1/-DX0
j
P1
4
+
3
+
2
()
(+)
1
()
(+)
Input
Load
Load
Load power
supply
Note:
Values in parentheses apply
to the DC-load versions.
4
3
2
1
+
()
(+)
+
()
(+)
Input
Load
Load
Input voltage
Load power supply
Note:
Values in parentheses apply
to the DC-load versions.
0.4
33 max.
25 max.
14.5
max.
20 max.
1.5 max.
25
0.5
12.5
0.5
10
0.5
0.7
0.7
0.7
0.4
33 max.
14 max.
26.5 max.
32 max.
1.5 max.
27.5
0.5
(17.5)
5
0.5
3
1
Four 1.2-dia.
holes
25
12.5
5
(17.5)
5
27.5
Two, 2-dia.
holes
Two, 4 dia.
holes
Two, 2-dia.
holes
Four 1.2-dia.
holes
Pattern
Pattern
10
Terminal Arrangement/
Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
Terminal Arrangement/
Mounting Holes
(Bottom View)
5
0.5
G3CN
G3CN
175
Precautions
Refer to pages 11 to 19 for general precautions.
Connection
With the SSR for DC switching, the load can be connected to either
positive or negative output terminal of the SSR.
Protective Component
Since the SSR does not incorporate an overvoltage absorption
component, be sure to connect an overvoltage absorption compo-
nent when using the SSR under an inductive load.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K063-E1-2A