ChipFind - документация

Электронный компонент: G5V-2-H1

Скачать:  PDF   ZIP
1
G5V-2
PCB Relay
Miniature Relay for Signal Circuits
I
Wide switching power of 10
A to 2 A.
I
High dielectric strength coil-contacts:1,000 VAC;
open contacts: 750 VAC.
I
Conforms to FCC Part 68 requirements.
I
Ag + Au clad bifurcated crossbar contacts and
fully sealed for high contact reliability.
I
New 150-mW relays with high-sensitivity.
Ordering Information
Model Number Legend
Specifications
I
Coil Ratings
Standard Models
4
+
FCC
Classification
Contact form
Contact type
Contact material
Enclosure ratings
Model
Standard
DPDT
Bifurcated crossbar
Ag + Au-clad
Fully sealed
G5V-2
High-sensitivity
G5V-2-H1
Rated coil voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-2 12 VDC
1. Contact Form
2: DPDT
2. Classification
H1: High-sensitivity
3. Rated Coil Voltage
3, 5, 6, 9, 12, 24, 48 VDC
G5V - - VDC
1
3
2
Rated voltage
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
Rated current
166.7 mA
100 mA
83.3 mA
55.6 mA
41.7 mA
20.8 mA
12 mA
Coil resistance
18
W
50
W
72
W
162
W
288
W
1,152
W
4,000
W
Coil inductance
(H) (ref. value)
Armature OFF
0.04
0.09
0.16
0.31
0.47
1.98
7.23
Armature ON
0.05
0.11
0.19
0.49
0.74
2.63
10.00
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
120% of rated voltage at 23
C
Power consumption
Approx. 500 mW
Approx.
580 mW
2
G5V-2
G5V-2
High Sensitivity Models
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
C with a tolerance of
10%.
2. Operating characteristics are measured at a coil temperature of 23
C.
I
Contact Ratings
Note
Note:P level:
l
60
= 0.1 x 10
6
/operation
I
Characteristics
Rated voltage
3 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
Rated current
50 mA
30 mA
25 mA
16.7 mA
12.5 mA
8.33 mA
6.25 mA
Coil resistance
60
W
166.7
W
240
W
540
W
960
W
2,880
W
7,680
W
Coil inductance
(H) (ref. value)
Armature ON
0.18
0.46
0.70
1.67
2.90
6.72
20.1
Armature OFF
0.57
0.71
0.97
2.33
3.99
9.27
26.7
Must operate voltage
75% max. of rated voltage
Must release voltage
5% min. of rated voltage
Max. voltage
180% of rated voltage at 23
C
150% of rated
voltage at
23
C
Power consumption
Approx. 150 mW
Approx.
200 mW
Approx.
300 mW
Item
Standard models
High sensitivity models
Load
Resistive load (cos
f
= 1)
Rated load
0.5 A at 125 VAC; 2 A at 30 VDC
0.5 A at 125 VAC; 1 A at 24 VDC
Contact material
Ag + Au-clad
Rated carry current
2 A
Max. switching voltage
125 VAC, 125 VDC
Max. switching current
2 A
1 A
Max. switching power
62.5 VA, 60 W
62.5 VA, 24 W
Failure rate (reference value)
0.01 mA at 10 mVDC
Item
Standard models
High sensitivity models
Contact resistance
50 m
W
max.
100 m
W
max.
Operate time
7 ms max.
Release time
3 ms max.
Bounce time
Operate: approx. 0.3 ms
Release: approx. 1.5 ms
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
W
min. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between con-
tacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts
of same polarity
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between con-
tacts of different polarity
500 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Impulse withstand voltage
1,500 V (10 x 160
s) between coil and contacts (conforms to FCC Part 68)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 200 m/s
2
(approx. 20G)
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 100 m/s
2
(approx. 10G)
Endurance
Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Ambient temperature
Operating:
-
25
C to 65
C (with no icing)
Operating:
-
25
C to 70
C (with no icing)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 5 g
3
G5V-2
G5V-2
I
Approved Standards
UL478, UL1950, UL508 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR24825)
Engineering Data
Contact form
Coil ratings
Contact ratings
G5V-2
G5V-2-H1
DPDT
3 to 48 VDC
0.6 A, 125 VAC (general use)
0.6 A, 110 VDC (resistive load)
2 A, 30 VDC (resistive load)
0.5 A, 125 VAC (general use)
0.2 A, 110 VDC (resistive load)
1 A, 24 VDC (resistive load)
Maximum Switching Power
G5V-2
Ambient Temperature vs.
Maximum Coil Voltage
G5V-2
Endurance
G5V-2
Switching current (A)
Switching voltage (V)
Switching current (A)
Endur
ance (x10 oper
ations)
3
Ambient temperature (
)
Maxim
um coil v
oltage (%)
Coil rated voltage
3 to 24 VDC
48 VDC
30-VDC
resistive
load
125-VAC resistive
load
1
2
3
AC resistive load
DC re
sistive
load
G5V-2-H1
G5V-2-H1
G5V-2-H1
Switching current (A)
Switching voltage (V)
Switching current (A)
Lif
e e
xpectancy (x10 oper
ations)
3
Ambient temperature (
)
Maxim
um coil v
oltage (%)
AC resistive
load
DC resistive load
5
3
1
0.7
0.5
0.3
0.2
0.1
0
24-VDC resistive load
125-VAC resistive load
1000
500
300
100
50
30
10
3 to 24 VDC
48 VDC
200
180
160
140
120
100
80
0
Note: The maximum coil voltage refers to the maxi-
mum value in a varying range of operating
power voltage, not a continuous voltage.
Note: The maximum coil voltage refers to the maxi-
mum value in a varying range of operating
power voltage, not a continuous voltage.
4
G5V-2
G5V-2
Dimensions
Note:
1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
Tolerance:
0.1
20.5 max.
20.3 typ.
10.1 max.
9.9 typ.
11.5 max.
11.4 typ.
0.5
3.5
7.62
0.3
0.5
7.62
5.08 5.08
(1.3)
7.62
(1.3)
Eight, 1-dia. holes
(1.2)
1
16
4
13
6
11
8
9
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K046-E1-2B