BABT
BABT Approved Relay
G6ABS
BABT Approved Relay Meeting the
Requirements of EN41003:1993 as
endorsed, formerly BS6301:1989
Amendment 5 for Supplementary
Isolation
BABT Approved No. CR/0098.
Height of only 8mm from PCB.
Wide switching load 10
A to 2A.
Fully sealed construction.
Ordering Information
Single-side Stable Type
Model
Classification
G6A234PBS
Contact Form DPDT
Contact Type Bifurcated
crossbar
Contact Material
AgPd+Au clad
Structure Plastic sealed
Rated coil voltage
Note:
When ordering, add the rated coil voltage to the model number.
Example: G6A-234P-BS 12 VDC
Specifications
Coil Ratings
General purpose, DPDT Relays
Rated voltage (VDC)
3
4.5
5
6
9
12
24
48
Rated current (mA)
93.8
62.5
56.2
46.5
31.1
23.3
11.7
7.0
Coil resistance (
)
32
72
89
129
289
514
2,057
6,882
Coil inductance
Armature OFF
0.07
0.16
0.2
0.29
0.63
1.1
4.5
13.7
(H) (ref. value)
Armature ON
0.065
0.14
0.18
0.26
0.57
1.06
4.1
12.5
Must operate voltage
70% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
150% of rated voltage at 23
_
C, 150% at 70
_
C
Power consumption
Approx. 280 mW
Approx.
330 mW
Contact Ratings
Item
G6A-234P-BS
Load
Resistive load
(cos
= 1)
Inductive load
(cos
= 0.4; L/R = 7 ms)
Rated load
0.3 A at 125 VAC;
1 A at 30 VDC
0.2 A at 125 VAC;
0.5 A at 30 VDC
Contact material
AgPd (Au-clad)
Rated carry current
3 A
Max. switching voltage
250 VAC, 220 VDC
Max. switching current
DC: 2A; AC: 2 A
DC: 1 A; AC: 1 A
Max. switching capacity
125 VA, 60 W
62.5 VA, 30 W
Min. permissible load
0.01 mA at 10 mVDC
G6ABS
G6ABS
Characteristics
(at Ambient Temperature 23
_
C)
Contact resistance
50 m
max.
Operate (set) time
5 ms max.
Release (reset) time
3 ms max.
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
min. (at 500 VDC)
Dielectric withstand voltage
1,000 VAC, 50/60 Hz for 1 min between open contacts
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
Impulse withstand voltage
1,500 V 10 x 160
s (conforms to FCC Part 68)
Vibration resistance
Destruction: 10 to 55 Hz, 5-mm double amplitude
Malfunction: 10 to 55 Hz, 3.3-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: DPDT:
500 m/s
2
(approx. 50G)
Life expectancy
Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical:
500,000 operations min. (at 1,800 operations/hr)
Ambient temperature
Operating: 40
_
C to 70
_
C (with no icing)
Storage:
40
_
C to 70
_
C (with no icing)
Ambient humidity
Operating: 45% to 85%
Weight
DPDT: Approx. 3.5 g
Note:
The data shown above are initial values.
Dimensions
Note:
1. Orientation marks are indicated as follows:
Terminal Arrangement/
Internal Connections
(Bottom View)
Mounting Holes
(Bottom View)
Tolerance:
+
0.1
1
16
4
13
6
11
8
9
+
7.62
5.08
5.08
(1.2)
7.62
(1.2)
(1.2)
(1.2)
Eight, 1.0-dia. holes
(20)* 20.2
max.
(9.9)* 10.1
max.
(8.2)*
8.4 max.
0.64
0.6
7.62
3.16
0.3