Document Outline
- PCB Relay G6S
- Ordering Information
- Specifications
- Coil Ratings
- Contact Ratings
- Characteristics
- Approved Standards
- Engineering Data
- Dimensions
- Precautions
1
PCB Relay
G6S
Surface Mount DPDT Relay
Long terminals for ideal for soldering and mounting
reliability.
Space-saving inside-L terminal.
High dielectric strength between coil and contacts
(2,000 VAC), and between contacts of different
polarity (1,500 VAC).
High impulse withstand voltages between coil and
contacts, and between contacts of different polarity
(2,500 V, 2 x 10
s: Bellcore requirements).
Low power consumption (140 mW).
Bifurcated crossbar contact (Au-clad) and plastic
sealed construction for high reliability.
Applicable to IRS.
High sealability after IRS.
Ultra-miniature at 15 x 7.5 x 9.4 mm (L x W x H).
Through-hole terminal is available
EN60950/EN41003 Supplementary Insulation-cer-
tified type is available.
Ordering Information
Classification
Single-side
stable
Single-winding
latching
Double-winding
latching
Single-side stable
EN60950/EN41003
DPDT
Plastic
l d
Through-hole terminal
G6S-2
G6SU-2
G6SK-2
G6S-2-Y
as c
sealed
Surface mount
t
i
l
Inside-L
G6S-2G
G6SU-2G
G6SK-2G
G6S-2G-Y
Su ace
ou
terminal
Outside-L
G6S-2F
G6SU-2F
G6SK-2F
G6S-2F-Y
Rated coil voltage
Note:
1. When ordering, add the rated coil voltage to the model number.
Example: G6S-2F 12 VDC
2. When ordering tape packing, add "-TR" to the model number.
Example: G6S-2F-TR 12 VDC
Be sure since "-TR" is not part of the relay model number, it is not marked on the relay case.
Tape packing
Model Number Legend:
G6S
j
-
jj
-
j j
VDC
1
2
3
4
5
1.
Relay Function
None: Single-side stable
U:
Single-winding latching
K:
Double-winding latching
2.
Contact Form
2:
DPDT
3.
Terminal Shape
None: Through-hole terminal
G:
Inside-L surface mount terminal
F:
Outside-L surface mount terminal
4.
Approved Standards
None: UL/CSA
Y:
EN60950/EN41003
5.
Rated Coil Voltage
(Refer to "Coil Ratings")
Back
G6S
G6S
2
Specifications
Coil Ratings
Single-side Stable Type (G6S-2, G6S-2F, G6S-2G)
Rated voltage
4.5 VDC
5 VDC
12 VDC
24 VDC
Rated current
31.0 mA
28.1 mA
11.7 mA
8.3 mA
Coil resistance
145
178
1,028
2,880
Must operate voltage
75% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
200% of rated voltage at 23
C, 130% at 85
C
170% of rated voltage
at 23
C, 130% at 85
C
Power consumption
Approx. 140 mW
Approx. 200 mW
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
C with a tolerance of
10%.
2. Operating characteristics are measured at a coil temperature of 23
C.
Single-winding Latching Type (G6SU-2, G6SU-2F, G6SU-2G)
Rated voltage
4.5 VDC
5 VDC
12 VDC
24 VDC
Rated current
22.2 mA
20 mA
8.3 mA
6.3 mA
Coil resistance
203
250
1,440
3,840
Coil inductance
(H) (
f
l
)
Armature OFF
0.27
0.36
2.12
5.80
Co
duc a ce
(H) (ref. value)
Armature ON
0.14
0.18
1.14
3.79
Must set voltage
75% max. of rated voltage
Must reset voltage
75% max. of rated voltage
Max. voltage
180% of rated voltage at 23
C, 140% at 85
C
Power consumption
Approx. 100 mW
Approx. 150 mW
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
C with a tolerance of
10%.
2. Operating characteristics are measured at a coil temperature of 23
C.
Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G)
Rated voltage
4.5 VDC
5 VDC
12 VDC
24 VDC
Rated current
44.4 mA
40 mA
16.7 mA
12.5 mA
Coil resistance
101
125
720
1,920
Coil
i d
t
Set
Armature OFF
0.12
0.14
0.60
1.98
Co
inductance
(H)
Armature ON
0.074
0.088
0.41
1.23
(H)
(ref. value)
Reset
Armature OFF
0.082
0.098
0.46
1.34
(ref. value)
Armature ON
0.14
0.16
0.54
2.23
Must set voltage
75% max. of rated voltage
Must reset voltage
75% max. of rated voltage
Max. voltage
170% of rated voltage at 23
C, 130% at 85
C
140% of rated voltage
at 23
C, 110% at 70
C
Power consumption
Approx. 200 mW
Approx. 300 mW
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
C with a tolerance of
10%.
2. Operating characteristics are measured at a coil temperature of 23
C.
Single-side Stable EN60950/EN41003 Approved Type (G6S-2-Y, G6S-2F-Y, G6S-2G-Y)
Rated voltage
5 VDC
12 VDC
24 VDC
Rated current
40 mA
16.7 mA
9.6 mA
Coil resistance
125
720
2,504
Must operate voltage
75% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
170% of rated voltage at 23
C, 130% at 85
C
170% of rated voltage
at 23
C, 110% at 70
C
Power consumption
Approx. 200 mW
Approx. 230 mW
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
C with a tolerance of
10%.
2. Operating characteristics are measured at a coil temperature of 23
C.
G6S
G6S
3
Contact Ratings
Load
Resistive load (cos
= 1)
Rated load
0.5 A at 125 VAC; 2 A at 30 VDC
Contact material
Ag (Au-clad)
Rated carry current
2 A
Max. switching voltage
250 VAC, 220 VDC
Max. switching current
2 A
Max. switching capacity
62.5 VA, 60 W
Min. permissible load
10
A at 10 mVDC
Note:
P level:
60
= 0.1 x 10
6
/operation
Characteristics
Contact resistance
75 m
max.
Operate (set)time
4 ms max. (mean value: approx. 2.5 ms; latching type: approx. 2 ms)
Release (reset) time
4 ms max. (mean value: approx. 1.5 ms; latching type: approx. 2 ms)
Bounce time
Operate: Approx. 0.5 ms
Release: Approx. 0.5 ms
Set/Reset: Approx. 0.5 ms
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between coil and contacts (double-winding latching)
1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
500 VAC, 50/60 Hz for 1 min between set and reset coil (double-winding latching)
Impulse withstand voltage
2,500 V, 2 x 10
s between coil and contacts
1,500 V, 10 x 160
s between coil and contacts (double-winding latching)
2,500 V, 2 x 10
s between contacts of different polarity
1,500 V, 10 x 160
s between contacts of same polarity (conforms to FCC Part 68)
Vibration resistance
Destruction: 10 to 55 Hz, 5-mm double amplitude
Malfunction: 10 to 55 Hz, 3.3-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 750 m/s
2
(approx. 75G)
Life expectance
Mechanical:100,000,000 operations min. (at 36,000 operations/hr)
Electrical:
100,000 operations min. (2 A at 30 VDC, resistive load: 1,200 operations/hr)
100,000 operations min. (0.5 A at 125 VAC, resistive load)
Ambient temperature
Operating: 40
C to 85
C (with no icing), 40
C to 70
C (double-winding latching, 24 VDC)
Storage:
40
C to 85
C (with no icing)
Ambient humidity
Operating: 35% to 85%
Weight
Approx. 2 g
Approved Standards
UL1950 (File No. E41515)/CSA C22.2 No.950 (File No. LR24825)
Model
Contact form
Coil ratings
Contact ratings
G6S-2, G6S-2F, G6S-2G
DPDT
1.5 to 48 VDC
2 A, 30 VDC
0 3 A 110 VDC
G6SU-2, G6SK-2, G6SU-2F,
G6SU-2G, G6SK-2F, G6SK-2G
1.5 to 24 VDC
, 30
C
0.3 A, 110 VDC
0.5 A, 125 VAC
EN60950/EN41003
Model
Contact form
Isolation category
Voltage
G6S-2-Y, G6S-2G-Y, G6S-2F-Y
DPDT
Supplementary Isolation
250 VAC
G6S
G6S
4
Engineering Data
Max. Switching Capacity
Single-winding Latching
Double-winding Latching
Switching current (A)
Switching voltage (V) Ambient temperature (
C)
Maximum voltage (%)
Ambient Temperature vs.
Maximum Voltage
Single-side Stable
Ambient temperature (
C)
Maximum voltage (%)
AC resistive load
DC resistive load
12 VDC max.
24 VDC
(G6S-Y, 12 VDC max.)
G6SU
G6SK
12 VDC
max.
G6SK
24 VDC
Reference Data
Ambient Temperature vs. Switching Current
Single-side Stable
Switching current (A)
Single-winding Latching
Double-winding Latching
Ambient temperature (
C)
Switching current (A)
Ambient temperature (
C)
12 VDC max.
G6SU
12 VDC max.
G6SU
24 VDC
G6SK
12 VDC max.
G6SK
24 VDC
24 VDC
(G6S-Y)
24 VDC
(G6S-Y, 12 VDC
max.)
24 VDC
(G6S-Y)
Recommended Soldering Time vs. Surface PCB Temperature
(The temperature profile indicates the temperature on the surface of the PCB.)
IRS
Time (s)
T
emperature ( C)
Soldering
Preheating
Soldering
Preheating
G6S
G6S
5
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Orientation mark
Single-side Stable
G6S-2, G6S-2-Y
Tolerance:
0.3
Footprint
(Bottom View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
G6S-2G, G6S-2G-Y
Tolerance:
0.3
Footprint
(Top View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Top View)
Orientation mark
G6S-2F, G6S-2F-Y
Tolerance:
0.3
Footprint
(Top View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Top View)
Eight, 1-dia. holes
Orientation mark
G6S
G6S
6
Single-winding Latching
G6SU-2
Tolerance:
0.3
Footprint
(Bottom View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
G6SU-2G
Tolerance:
0.3
Footprint
(Top View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Top View)
Orientation mark
Orientation mark
7.3
0.2
7.3
0.2
G6SU-2F
Tolerance:
0.3
Footprint
(Top View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Top View)
Eight, 1-dia. holes
Orientation mark
G6S
G6S
7
Double-winding Latching
G6SK-2
Tolerance:
0.3
Footprint
(Bottom View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
G6SK-2G
Tolerance:
0.3
Footprint
(Top View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Top View)
Orientation mark
Orientation mark
7.3
0.2
G6SK-2F
Tolerance:
0.3
Footprint
(Top View)
Tolerance:
0.1
Terminal Arrangement/
Internal Connections
(Top View)
Ten, 1-dia. holes
Orientation mark
G6S
G6S
8
Tape Packing
When ordering, add "-TR" before the rated coil voltage for tape packing.
Tape type:
TE2416R (Refer to EIAJ)
Reel type:
R24E (Refer to EIAJ)
Relays per reel: 400
G6S-2F, G6SU-2F, G6SK-2F, G6S-2F-Y
G6S-2G, G6SU-2G, G6SK-2G, G6S-2G-Y
Cover tape
Emboss tape
Carrier tape
13
0.2
Feed direction
Orientation mark
21
0.5
2
0.3
29.5
1.0
25.5
0.5
R1.0
330
80
Precautions
Use a DC power supply with 5% or less ripple factor to operate the
coil.
Do not use the G6S where subject to strong external magnetic
fields.
Do not use the G6S where subject to magnetic particles or exces-
sive amounts of dust.
Do not reverse the polarity of the coil (+, ).
Latching types are delivered in the reset position. We recommend
that a reset voltage be applied in advance to start operation.
Do not drop the G6S or otherwise subject it to excessive shock.
Remove the relay from the packing immediately prior to usage.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K93-E1-2C