ChipFind - документация

Электронный компонент: FO141

Скачать:  PDF   ZIP
FO141 06/2001
Solutions for Today
1
Lamps designed for increased light output can have a reduced operating life
2
Lamps designed with a longer operating life can produce fewer lumens
3
Lamps operated at less than their rated voltage provide a longer life, reduced light output and lower color
temperature. A 5% reduction in voltage can double lamp life, decrease luminous flux by 15% and decrease color
temperature by 2%.
4
Screen Lumens
If you are using:
Upgrade to:
Benefits
ENX
FXL
Increased light
FXL or ENX
FXL-HL
Increased light
1
FCR 64625 HLX
EVA 64623 HLX
Increased life by 40 times
2
FCS 64640 HLX
FDV 64642 HLX
Increased life by 6 times
2
EHJ 64655 HLX
EVC 64657 HLX
Increased life by 6 times
2
EVC 64657 HLX
FNT 64656PT HLX
Increased light by 10%
1
EVD 64663 HLX
64664 HLX
Increased life by 3 times
2
at 36V
EVD 64663 HLX
64665 HLX
Increased life by 6 times
2
at 36V
BHC/DYS/DYV
BHC/DYS/DYV-5
Double the life at 120V
3
EYB
EYB-5
Double the life at 82V
3
EYB
EYB-7
Increased life by 2.5 times at 82V
3
ENX
ENX-5
Double the life at 82V
3
ENX
ENX-7
Increased life by 2.5 times at 82V
3
Upgrades For
Upgrades For
Popular
Projection Lamps
Projection Lamps
Technical Data
Technical Data
Order
Abbreviation
Product
Number
Watts
Volts
Rated
life
Fig. Base
"l"
mm
"a"
mm
"d"
mm
Bulb
Shape
Lumens
FXL
54912
410
82
75
1
GY5.3
38.1 299
51
T3.5
640
4
FXL-HL
54904
410
82
40
1
GY5.3
38.1 299
51
T3.5
850
4
FCR 64625 HLX
54036
100
12
50
2
GY6.35 44
30
11.5 T3.5
3,600
EVA 64623 HLX
54052
100
12
2,000
2
GY6.35 44
30
11.5 T4
2,800
FCS 64640 HLX
54041
150
24
50
2
G6.35
50
32
13.5 T4
6,000
FDV 64642 HLX
54054
150
24
300
2
G6.35
50
32
13.5 T4
5,000
EHJ 64655 HLX
54045
250
24
50
2
G6.35
55
33
13.5 T4
10,000
EVC 64657 HLX
54047
250
24
300
2
G6.35
55
33
13.5 T4
9,000
FNT 64656PT HLX
54044
275
24
75
2
G6.35
55
33
13.5 T4
10,000
EVD 64663 HLX
54100
400
36
50
2
G6.35
60
36
15
T6
16,000
64664 HLX
54057
400
36
150
2
G6.35
57
36
18
T6
14,500
64665 HLX
54058
400
36
300
2
G6.35
60
36
18
T6
12,200
BHC/DYS/DYV
54836
600
120
75
3
GZ9.5
64
36.5 20
T6
17,500
BHC/DYS/DYV-5
54835
600
125
75
3
GZ9.5
63.5 36.5 20
T6
17,500
EYB
54446
360
82
75
4
G5.3
57.2 31.8 11.2 T3.5
10,000
EYB-5
54448
360
85.5
75
4
G5.3
54
31.8 11.2 T3.5
10,000
EYB-7
54455
360
87.5
75
4
G5.3
57.2 31.8 11.2 T3.5
10,000
ENX
54984
360
82
75
1
GY5.3
45
299
51
T3.5
460
4
ENX-5
54913
360
86
75
1
GY5.3
38.1 299
51
T3.5
540
4
ENX-7
54916
360
87.5
75
1
GY5.3
38.1 299
51
T3.5
540
4
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4