ChipFind - документация

Электронный компонент: DFC6U5S15

Скачать:  PDF   ZIP
1
FEATURES
Ultra-Wide 3.5 to 16 Volt Input Range
Input Filtered
6 Watts of Output Power
Efficiencies to 77%
700V Isolation
Low Input to Output Capacitance
Ultra-Wide Input Range (4:1)
DESCRIPTION
Designed for digital, ECL, and analog application, the DFC6
Series will provide up to 6 watts in an industry standard package.
Ultra-wide range input voltage allows operation from battery
power as well as system power. The output is electrically isolated,
thereby allowing the output to be configured as a positive or
negative output voltage. Fully isolated and filtered outputs permit
usage in sensitive and low noise circuits.
The 100KHz operating frequency of the DFC6 Series allows an
increased power density while including adequate heat sinking
and input/output filtering. This eliminates the need for external
components in most applications.
Mechanical tolerances unless otherwise noted:
X.XX dimensions: 0.020 inches
X.XXX dimensions: 0.005 inches
0.80
0.60
0.000
0.3
0.45
0.000
0.300
0.500
0.000
0.200
2.00
1.00
(12.70)
0.60
(15.2)
(5.08)
(7.62)
(15.2)
(20.32)
1
2
3
4
(7.62)
(11.43)
(25.40)
(50.80)
.040 (1.02) DIA
4 PLACES
BOTTOM VIEW
SIDE VIEW
NOTES
(1)
All parameters measured at Tc=25C, nominal input voltage and full rated load unless otherwise noted.
Refer to the Technical Reference Section for the definition of terms, measurement circuits and other
information.
(2)
The functional temperature range is intended to give an additional data point for use in evaluating this
power supply. At the low functional temperature the power supply will function with no side effects,
however, sustained operation at the high functional temperature will reduce expected operational life.
The data sheet specifications are not guaranteed beyond the case operating range.
(3)
The case Thermal Impedance is specified as the case temperature rise over ambient per package
dissipated.
(4)
Reduced output power available with 3.5V input. Full power is available above 4.6V input. See input
voltage derating curve for more information
DFC6 SERIES
SINGLE OUTPUT
Rev. 04/2000
2
NOTES
(1) All parameters measured at Tc=25C, nominal input voltage and full rated load unless otherwise
noted. Refer to the Technical Reference Section for the definition of terms, measurement circuits and
other information.
(2) Reduced output power available at 3.5V input. Full output power is available above 4.6V input. See
input voltage derating curve for more information.
(3) Noise is measured per Technical Reference Section. Measurement bandwidth is
0-20 MHz for peak-peak measurements, 10 kHz to 1 MHz for RMS measurements. Output noise is
measured with a 1F/35V Tantalum capacitor located 1" away from the converter to simulate PCB
standard decoupling.
(4) Short term stability is specified after a 30 minute warmup at full load, constant line and recording the
drift over a 24 hour period.
(5) No minimum load required for operation. Dynamic regulation may degrade when run with less
than 5% load.
DFC6 SERIES APPLICATION NOTES:
External Capacitance Requirements
No external capacitance is required for operation of the DFC6
Series. To meet the reflected ripple requirements of the converter,
an input impedance of less than 0.15 Ohms from DC to 200KHz
is required. If a capacitive input source is farther than 1" from the
converter, an additional capacitor may be required at the input
pins for proper operation. External output capacitance is not
DFC6 SERIES SINGLE OUTPUT
required for operation, however it is recommended that 1 F to
10 F of tantalum and 0.001 to 0.1 F ceramic capacitance be
selected for reduced system noise. Additional output capacitance
may be added for increased filtering, but should not exceed 400 F.
Output Power
The available output power of the DFC6 Series is reduced when
operating below 4.6 volts. See Input Voltage Derating curve. Below
4.6 volts the output power is linearly derated from 100% at 4.6
volts to 50% at 3.5 volts.
Negative Outputs
A negative output voltage may be obtained by connecting the
+OUT to circuit ground and connecting -OUT as the negative
output.
3
Typical Performance: (Tc=25C, Vin=Nom VDC, Rated Load)
80
75
70
65
60
0
40
30
20
LINE = 16VDC
LINE = 5VDC
10
50
60
70
80
90 100
EFFICIENCY Vs. LOAD
LOAD (%)
EFFICIENCY (%)
4.0
3.0
3.5
2.0
2.5
1.0
1.5
0.5
0.0
0
8
6
4
100% LOAD
50% LOAD
2
10
12
14
16
INPUT CURRENT Vs. INPUT VOLTAGE
LINE INPUT (VOLTS)
INPUT CURRENT (AMPS)
10
1
.1
.01
10
100000
10000
1000
12/15 VOLT OUTPUT
5 VOLT OUTPUT
100
1000000
OUTPUT IMPEDENCE Vs. FREQUENCY
FREQUENCY (Hz)
OUTPUT IMPEDENCE (OHMS)
85
80
75
70
65
4
12
14
10
8
100% FULL LOAD
50% FULL LOAD
6
16
EFFICIENCY Vs. LINE INPUT VOLTAGE
LINE INPUT (VOLTS)
EFFICIENCY (%)
1.0
0.8
0.4
0.6
0.2
0.0
3
11
13
15
9
7
100% LOAD
75% LOAD
50% LOAD
5
17
RMS INPUT CURRENT Vs. LINE INPUT
LINE INPUT (VDC)
RMS INPUT CURRENT (AMPS)
120
80
100
40
60
20
0
3.50
4.50
4.75
4.25
4.00
3.75
5.00
INPUT VOLTAGE DERATING
LINE INPUT (VDC)
% AVAILABLE POWER
50
40
0
2
1
3
4
5
6
60
70
80
90
OUTPUT POWER DERATING
AMBIENT TEMPERATURE
POWER OUTPUT
DFC6 SERIES SINGLE OUTPUT
DFC6 SERIES BLOCK DIAGRAM
3
+ OUTPUT
SHIELDED ISOLATION TRANSFORMER
+
4
- OUTPUT
ISO AMP
LOW TC
BANDGAP
REFERENCE
NONCONDUCTIVE PLASTIC CASE
+
+
2
INPUT
1
+ INPUT
CURRENT
MODE
PWM
www.power-one.com
www.power-one.com
For the Most Up-To-Date Information
24 Hours/Day--7 Days/Week
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.