ChipFind - документация

Электронный компонент: FRD2815

Скачать:  PDF   ZIP
(888) IPD-CONVerters
q
(888) 473-2668
q
www.ipdconverters.com
C-64
25
30
35
40
45
50
55
60
65
70
10
20
30
40
50
60
70
80
90
10
LOAD %
EFFICIENCY
%
EFF. FRD4812
EFF. FRD4815
35
40
45
50
55
60
65
70
75
80
10
20
30
40
50
60
70
80
90
10
LOAD %
EFFICIENCY %
EFF. FRD2812
EFF. FRD2815)
TECHNICAL SPECIFICATIONS
DESCRIPTION
FEATURES
Efficiency vs. Load (48V Input)
Efficiency vs. Load (28V Input)
FRD SERIES - DUAL OUTPUT, 5 WATT
Wide Input Range
Trim and Enable Pins
Remote Sense Pins
500V Isolation
Short Circuit Protection
6-Sided Shielding
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
FRD dual output DC/DC converters offer excellent
regulation and isolation in an industry standard
package. Available in several input versions, the FRD
is perfect for industrial, datacom, or telecom
applications. The FRD features short circuit
protection, six-sided shielding, and 500 VDC isolation.
Please see the FRS series for single output applications.
Input
Voltage Range
5V, 12V, 24V, 28V, and 48V Nominal
See selection chart for specific input range.
Reflected Ripple
20% I
in
Max.
Reverse Input Current
100% I
in
Max.
General
Switching Frequency
20 kHz
Isolation
Input - Output
500 VDC
Isolation Resistance - Input to Output
10
9
Ohms
Case Temperature
Operating Range
-25 To +85C
Storage Range
-40 To +125C
Humidity Max, Non-Condensing
95%
Temperature Coefficient
0.02%/C
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
Safety
Consult Factory
Weight (Approx.)
2.2 oz
Output
Setpoint Accuracy
1% V
out
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
0.15% V
out
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
0.15% V
out
I
out
Rated
Minimum Output Current
10 % l
out
Rated
Short Circuit Protection
1
Continuous
C-65
Thermal Impedance
Natural convection
10.3 C/W
100 LFM
7.7 C/W
200 LFM
6.3 C/W
300 LFM
5.1 C/W
400 LFM
4.1 C/W
Tolerances
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
FRD SERIES - DUAL OUTPUT, 5 WATT
MECHANICAL DRAWING
1
+V
in
2
-V
in
3
+ V
out
4
Common
5
- V
out
Inches: (Millimeters)
.XX 0.040 .X 1.0
.XXX 0.010 .XX 0.25
Pin:
0.002 0.05
Case:
+ 0.04, - 0.00 + 1.0, - 0.0
(Tolerances as listed unless otherwise specified.)
Pin Function
MODELS - (See the last page of this file for options.)
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
Model
5
5
12
12
24
24
28
28
48
48
4.65 - 5.50
4.65 - 5.50
10.90 - 13.20
10.90 - 13.20
21.60 - 26.40
21.60 - 26.40
25.20 - 30.80
25.20 - 30.80
43.20 - 52.80
43.20 - 52.80
2.01
2.04
0.85
0.86
0.43
0.45
0.37
0.38
0.21
0.22
12
15
12
15
12
15
12
15
12
15
0.23
0.19
0.23
0.19
0.23
0.19
0.23
0.19
0.23
0.19
40
40
40
40
40
40
40
40
40
40
65%
66%
66%
67%
66%
65%
69%
71%
65%
66%
FRD512
FRD515
FRD1212
FRD1215
FRD2412
FRD2415
FRD2812
FRD2815
FRD4812
FRD4815
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
1.40"
1.10"
0.800"
0.200"
0
(50.8mm)
2.00"
(50.8mm)
2.00"
0.18"(4.6mm) MIN.
0
5
4
2
1
3
(1.0mm)
DIA 0.040"
(10.2mm)
0.40"
0.500"
(12.7mm)
0.100"
(2.5mm)
-0.300"
(-7.6mm)
(35.6mm)
(20.3mm)
(5.1mm)
(27.9mm)
BOTTOM VIEW
C105
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
SUFFIX
APPLICABLE SERIES
REMARKS
Negative Logic
N
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Lucent Compatible Trim
T
HAS, HBD, HBS, HES, QBS, QES
Terminal Strip TS XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180"
(4.6mm)
0.110" (2.8mm) Pin Length
8
All Units (Except SMS)
0.150" (3.8mm) Pin Length
9
All Units (Except SMS)
0.24" (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink
1V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45" (11.4mm) Horizontal
Heatsink
2H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45" (11.4mm) Vertical Heatsink
2V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95" (24.1mm) Horizontal
Heatsink
3H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95" (24.1mm) Vertical Heatsink
3V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
Example Options: HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95" vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110" pin length.
NUCLEAR AND MEDICAL APPLICATIONS
Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS
The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.