ChipFind - документация

Электронный компонент: HBS100ZE-A

Скачать:  PDF   ZIP
(888) IPD-CONVerters
q
(888) 473-2668
q
www.ipdconverters.com
1
Turn-On Time
10 ms
Remote Shutdown
Positive Or Negative Logic
Remote Shutdown Reference
V
in
Negative
Switching Frequency
500 kHz
Isolation, Input - Output
1500 VDC
Isolation, Input - Case
1050 VDC
Isolation, Output - Case
500 VDC
Temperature Coefficient
0.2%/C
Case Temperature
Operating Range
-40 To +100C
Storage Range
-40 To +125C
Thermal Shutdown Range
105 To 115C
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
MTBF (Bellcore TR-NWT-000332)
2.1 x 10
6
hrs
Safety
UL, CUL, VDE
Weight (approx.)
2.5 oz
TECHNICAL SPECIFICATIONS
Voltage Range
24 VDC Nominal
18 - 36 VDC
48 VDC Nominal
34 - 75 VDC
Reflected Ripple
25 mA
Input Reverse Voltage Protection
Shunt Diode
HBS DC/DC converters provide up to 100 Watts of
output power in an industry standard half-brick package
and footprint. These units feature excellent efficiency,
Class A conducted noise specs, and fixed switching
frequency. The HBS features open-frame packaging,
along with planar magnetics to provide maximum
useable power with minimal thermal constraints. The
HBS is especially suited to telecom, networking, and
industrial applications, and is fully compatible with
production board washing processes.
Industry Standard Half-
Brick
Open-Frame Packaging
100C Baseplate Operation
Water Washable
"True-Trim" Option
1500V Isolation
Positive Or Negative
Logic
Setpoint Accuracy
1%
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
0.2% V
out
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
0.2% V
out
Remote Sense Headroom
0.5 VDC
Minimum Output Current
10 % I
out
Rated
Dynamic Regulation, Loadstep
25% I
out
Pk Deviation
4% V
out
Settling Time
500
s
Voltage Trim Range
10%
Short Circuit / Overcurrent Protection
Hiccup
Current Limit Threshold Range, % of I
out
Rated
110 - 140%
OVP Trip Range
115 - 140% V
out
Nom.
OVP
Hiccup
Output
DESCRIPTION
FEATURES
HBS SERIES - 100 WATT
Input
General
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
60
65
70
75
80
85
90
10
20
30
40
50
60
70
80
90
100
LOAD %
EFFICIENCY %
HBS100ZG-A
Efficiency vs. Load (48V Input)
HBS100YJ-A
72
74
76
78
80
82
84
86
88
90
10
20
30
40
50
60
70
80
90
100
LOAD %
EFFICIENCY %
EFF. (18V)
EFF. (24V)
EFF. (36V)
Efficiency vs. Load (24V Input)
2
Thermal Impedance
Natural Convection
6.6 C/W
100 LFM
5.7 C/W
200 LFM
4.2 C/W
300 LFM
3.1 C/W
400 LFM
2.6 C/W
Tolerances
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
HBS SERIES - 100 WATT
MECHANICAL DRAWING
1
-V
in
2
Case
3
On/Off
4
+V
in
5
-V
out
6
-Sense
7
Trim
8
+Sense
9
+V
out
Inches: (Millimeters)
.XX 0.020 .X 0.5
.XXX 0.010 .XX 0.25
Pin:
0.002 0.05
(Dimensions as listed unless otherwise
specified.)
P i n
Function
MODELS - (See the last page of this file for options.)
BOTTOM VIEW
0.400"(10.2mm)
1.000"(25.4mm)
1.400"(35.6mm)
0.700"(17.8mm)
0
-0.50"(-12.7mm)
(61.0mm)
2.40"
M3X.5 THROUGH 4PL
MOUNTING INSERTS
(57.9mm)
2.28"
HBS
9
8
7
6
5
4
3
2
1
(0.6mm)
(2.0mm)
(1.0mm)
(4.6mm)
0.18"
(12.7mm)
0.50"
0.025" REF.
DIA 0.040"
DIA 0.080"
(48.3mm)
1.900"
(-4.8mm)
-0.19"
0
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
Model
24
24
24
24
48
48
48
48
18 - 36
18 - 36
18 - 36
18 - 36
34 - 75
34 - 75
34 - 75
34 - 75
7.00
7.20
7.00
7.00
3.65
3.60
3.50
3.50
3.3
5
12
15
3.3
5
12
15
30.00
20.00
8.30
6.70
30.00
20.00
8.30
6.70
100
100
150
150
100
100
150
150
80%
83%
85%
86%
80%
84%
86%
87%
HBS100YE-A
HBS100YG-A
HBS100YH-A
HBS100YJ-A
HBS100ZE-A
HBS100ZG-A
HBS100ZH-A
HBS100ZJ-A
Denotes advanced product release. Consult factory for product availability.
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
3
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
SUFFIX
APPLICABLE SERIES
REMARKS
Negative Logic
N
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Lucent Compatible Trim
T
HAS, HBD, HBS, HES, QBS, QES
Terminal Strip TS XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180"
(4.6mm)
0.110" (2.8mm) Pin Length
8
All Units (Except SMS)
0.150" (3.8mm) Pin Length
9
All Units (Except SMS)
0.24" (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink
1V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45" (11.4mm) Horizontal
Heatsink
2H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.45" (11.4mm) Vertical Heatsink
2V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95" (24.1mm) Horizontal
Heatsink
3H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
0.95" (24.1mm) Vertical Heatsink
3V
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
Example Options: HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95" vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110" pin length.
NUCLEAR AND MEDICAL APPLICATIONS
Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS
The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.