1
LES010YE-A
45
50
55
60
65
70
75
80
85
10
20
30
40
50
60
70
80
90
100
LOAD %
EFFICIENCY %
EFF. (18v)
EFF. (24v)
EFF. (36v)
50
55
60
65
70
75
80
85
10
20
30
40
50
60
70
80
90
100
LOAD %
EFFICIENCY %
LES010ZE
LES015ZG
Efficiency vs. Load (48V Input)
Setpoint Accuracy
1%
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
0.2% V
out
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
0.5% V
out
Minimum Output Current
10% I
out
Rated
Dynamic Regulation, Loadstep
25% I
out
Pk Deviation
2% V
out
Settling Time
500
s
Voltage Trim Range
10%
Short Circuit / Overcurrent Protection
Shutdown / Hiccup
Current Limit Threshold Range, % of I
out
Rated
110 - 150%
Short Circuit Current Max.
200% I
out
(12Vout & 15Vout : 4.0A when Vout= 0.25V)
OVP Trip Range
115 -140% V
out
Nom.
OVP Type
Second Control Loop
TECHNICAL SPECIFICATIONS
LES DC/DC converters provide up to 15 Watts of output
power in an industry standard package and footprint. With
a maximum case temperature of 100C, the LES is well
suited for the most demanding telecom, networking, and
industrial applications. The LES features 1500 VDC
isolation, short circuit, and overtemperature protection, as
well as six-sided shielding. The LES is available with
optional enable and voltage trim pins. Please see the IAD
Series for dual output applications.
Industry Standard Package
Industry Standard Pinout
85C Case Operation
Short Circuit Protection
24V and 48V Inputs
Input Pi Filter and
6-Sided Shielding
Regulated Outputs
1500V Isolation
DESCRIPTION
FEATURES
Efficiency vs. Load (24V Input)
Voltage Range
24 VDC Nominal
18 - 36 VDC
48 VDC Nominal
36 - 75 VDC
Reflected Ripple
50 mA
Input
Output
General
Turn-On Time
10 mS
Remote Shutdown
Positive/Negative Logic
Switching Frequency
400 kHz
Isolation
Input - Output
1500 VDC
Output - Case
500 VDC
Temperature Coefficient
0.02 ppm/C
Case Temperature
Operating Range
-40 To +100C
Storage Range
-40 To +100C
Humidity Max., Non-Condensing
95%
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
MTBF
(Bellcore TR-NWT-000332)
2.5 X 106 hrs
Safety
UL, cUL, TUV
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260
C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or immersion
post wave-solder washing equipment.
Rev. 06/01
LES SERIES - 15 WATT
OPTION
SUFFIX
APPLICABLE SERIES
REMARKS
Negative Logic
N
HAS, HBD, HBS, HES, HLS, HLD, LES,
TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD
TTL "High" Turns Module OFF
Lucent-Compatible
T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Terminal Strip
TS
XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
Pin Length and Heatsink Options
Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length
8
All Units (Except SMS)
0.150" (3.8mm) Pin Length
9
All Units (Except SMS)
0.24" (6.1mm) Horizontal Heatsink
1H
All Units (All Units Except DIP, HLS, HLD, QLS,
Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heatsink
1V
All Units (All Units Except DIP, HLS, HLD, QLS,
Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink
2H
All Units (All Units Except DIP, HLS, HLD, QLS,
Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heatsink
2V
All Units (All Units Except DIP, HLS, HLD, QLS,
Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink
3H
All Units (All Units Except DIP, HLS, HLD, QLS,
Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heatsink
3V
All Units (All Units Except DIP, HLS, HLD, QLS,
Includes Thermal Pad
SIP, SM, TLD, and TKD Packages)
3
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer
and add them to the model number. Example ordering options are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95" vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110" pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
OPTIONS