1
MAP140 SERIES
Power-One's MAP140 series provides a full range of options and up
to 30 watts more power than comparable products in this industry
standard footprint. With a universal input from 85 to 264 VAC and
power densities up to 2.6 watts/inch
3
, the MAP140 meets the most
rigorous requirements of commercial, industrial, and datacom systems.
Rated for use in convection and forced air cooled (200 LFM)
applications, the MAP140 delivers dependable power with a Mean
Time Before Failure (MTBF) in excess of 180,000 hours. In addition
to UL, CSA, and TV regulatory compliance, the MAP140 displays
the CE Mark.
FEATURES
Universal Input 85-264 VAC
Input Transient & ESD Compliance to EN61000-4-2/-3/-4
CE Marked to Low Voltage Directive
Industry Standard Footprint: 7.00" x 4.30" x 1.80"
(177.8mm x 109.2mm x 45.7mm)
Remote Sense and Overvoltage Protection
Power Fail Signal Standard on MAP140-3000P, Optional
on MAP140-1012 and MAP140-1024
Optional Overtemperature Protection, L-Bracket, and Cover.
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT
ADJUSTMENT
CONVECTION
FORCED AIR
LINE
LOAD
RIPPLE & NOISE
INITIAL SETTING
VOLTAGE
RANGE
COOLED CURRENT
CURRENT (NOTE 3)
REGULATION
REGULATION
%p-p (NOTE 1)
ACCURACY
MAP140-1012
12V/15V
11.0V to 16.0V
9.2/7.3A (Note 2)
12.5A/10A (Note 2)
0.1%
0.5%
1%
11.97V to 12.03V
MAP140-1024
24V/28V
22.8V to 29.2V
4.6/4A (Note 2)
6.3A/5.4A (Note 2)
0.1%
0.5%
1%
23.95V to 24.05V
MAP140-1048
48V
45.6V to 54.0V
2.3A
3.1A
0.1%
0.5%
1%
47.9V to 48.1V
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024 output currents are expressed as 24V/28V operation.
3) With 200 LFM forced air cooling.
MULTIPLE OUTPUT MODEL SELECTION CHART
80W CONVECTION COOLED, 140W FORCED AIR COOLED (200 LFM)
MODEL
OUTPUT
ADJUSTMENT
OUTPUT
PEAK OUTPUT
LINE
LOAD
RIPPLE & NOISE
INITIAL SETTING
VOLTAGE
RANGE
CURRENT (NOTE 1)
CURRENT (NOTE 1)
REGULATION
REGULATION
%p-p (NOTE 2)
ACCURACY
+5V
4.75 - 5.25V
16A/25A
20A/25A PK
0.2%
1%
1%
5.09V to 5.11V
MAP140-3000P
+12V
Fixed
4A/9A PK
4A/9A PK
0.1%
2%
1%
11.97V to 12.03V
-12V
Fixed
1A/1.5A PK
1A/1.5A PK
0.1%
2%
1%
-11.4V to -12.6V
NOTES: 1) Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Continuous input range.
85
264
VAC
Input Frequency
AC input.
47
63
Hz
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated loads.
85
VAC
Hold-up Time
Nominal AC input voltage (110 VAC) 110 watt load:
20
mS
140 watt load:
16
Input Current
85 VAC (140W load).
2.5
A
RMS
110 VAC (140W load).
2.0
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor. Vin = 264VAC (one cycle). 25C.
41
A
PK
Operating Frequency
Switching frequency of main transformer.
22
kHz
Rev. 04/2000
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
2
MAP140 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full load, 110 VAC. Varies with distribution of loads among outputs.
65
70
80
%
Minimum Loads
Single output models.
0
Amps
MAP140-3000P, total output current of V1 + V2 (Note 1).
2
Ripple and Noise
Full load, 20MHz bandwidth.
See Model Selection Chart.
Output Power
Single output models.
See Model Selection Chart.
MAP140-3000P with convection cooling.
80
Watts
MAP140-3000P with 200 LFM forced air cooling.
140
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on/turn-off.
0
V
Regulation
Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264,
See Model Selection Chart.
changes in load starting at 20% load and changing to 100% load.
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100%
500
S
load change, 4% max. deviation.
Turn-on Delay
Time required for initial output voltage stabilization.
MAP140-3000P
1
Sec
Single output models
2
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
20
mS
NOTES: 1) Minimum load is required only to meet the regulation limits of V3.
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on single output models
MAP140-3000P, V1
6.1
7.2
and V1 of MAP140-3000P.
MAP140-1012
17.3
20.2
V
MAP140-1024
32.2
37.8
MAP140-1048
55.2
64.8
Overload Protection
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Remote Sense
Voltage drop compensated for at the load.
250
mV
Input Power Fail
TTL compatible logic signal. Time before regulation dropout due
Warning
to loss of input power at 140 watts, 110 VAC. Standard on MAP140-3000P
2.3
mS
and optional on MAP140-1012.
Overtemperature Protection
Optional signal provides system shutdown due to excessive internal temperature. See options.
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL1950.
CSA 22.2 No. 234/950.
Approved
EN60950 (TV).
Dielectric Withstand Voltage
Input to output, 1 second.
2600
VDC
Electromagnetic
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
B
Class
Interference, Conducted
EN55022 / CISPR 22 conducted.
B
ESD Susceptibility
Per EN61000-4-2, level 4.
8
kV
Radiated Susceptibility
Per EN61000-4-3, level 3.
10
V/M
EFT/Burst
Per EN61000-4-4, level 3.
2
kV
Input Transient Protection
Per EN61000-4-5, class 3.
Line to Line
1
kV
Line to Ground
2
Insulation Resistance
Input to Output.
10
M
Leakage Current
Per EN60950, 264VAC.
110 VAC
0.5
mA
264 VAC
1.5
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating.
10k
ASL Ft.
Non-operating.
40k
ASL Ft.
Operating Temperature
Derate linearly above 50C by 2.5% per C
At 100% load:
0
50
C
At 50% load:
0
70
C
Storage Temperature
-40
85
C
Temperature Coefficient
0C to 70C (after 15 minute warm-up period).
0.02
0.05
%/C
Relative Humidity
Non-condensing.
95
%RH
Shock
Operating, peak acceleration.
20
G
PK
Vibration
Random vibration, 10Hz to 2kHz, 3 axis.
6
G
RMS
3
MAP140 SERIES
OPTIONS
DESCRIPTION
NOTES
DIMENSIONS
L-Bracket
Add `L' suffix to model number.
7.19" x 4.50" x 2.40"
(182.6mm x 114.3mm x 61.0mm)
Cover
Add `C' suffix to model number. Includes L-Bracket.
7.19" x 4.50" x 2.40"
For convection cooled applications, derate output power to 75 watts, maximum.
(182.6mm x 114.3mm x 61.0mm)
Power Fail Signal
Add `P' suffix to model number. Provides 2.3mS warning time before main output
drops 5%. Warning time increases at reduced load levels. Option available only
N/A
on MAP140-1012 and MAP140-1024. Power fail is standard on MAP140-3000P.
Thermal Shutdown
Add `T' suffix to model number. Initiates shut-down in the event of an overtemperature
N/A
condition. Automatic recovery. Where available, Power Fail signal is initiated prior to shutdown.
OVERALL SIZE: 7.00" X 4.30" X 1.97" (177.8mm x 109.2mm x 50.0mm)
OVERALL WEIGHT: 1.3 LBS (0.59 kg)
Contact factory for dimensions for L-bracket and cover.