NET1 SERIES
MULTIPLE OUTPUT MODEL SELECTION CHART
240W WITH 300 LFM FORCED AIR COOLING
MODEL
OUTPUT
ADJUSTMENT
OUTPUT
LINE
LOAD
RIPPLE & NOISE
INITIAL SETTING
VOLTAGE
RANGE
CURRENT (NOTE 1)
REGULATION
REGULATION
%Pk-Pk (NOTE 2)
ACCURACY
+3.3V
+0.5V
50A
0.2%
1%
1% or 50mV
30mV
NET1-4325
+2.5V
+0.5V
50A
0.2%
1%
1% or 50mV
30mV
+5V
FIXED
5A
0.2%
3%
1% or 50mV
30mV
+12V
FIXED
4A
0.2%
3%
1% or 50mV
100mV
+1.8V
+0.5V
50A
0.2%
1%
1% or 50mV
20mV
NET1-4130
+3.3V
+0.5V
50A
0.2%
1%
1% or 50mV
30mV
+5V
FIXED
5A
0.2%
3%
1% or 50mV
30mV
+12V
FIXED
4A
0.2%
3%
1% or 50mV
100mV
+1.8V
+0.5V
50A
0.2%
1%
1% or 50mV
20mV
NET1-4112
+1.65V
+0.5V
50A
0.2%
1%
1% or 50mV
30mV
+5V
FIXED
5A
0.2%
3%
1% or 50mV
30mV
+12V
FIXED
4A
0.2%
3%
1% or 50mV
100mV
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
TYP
MAX
UNITS
Input Voltage - AC
Continuous input range.
85
264
VAC
Input Frequency
AC input.
47
63
Hz
Hold-up Time After last AC line peak at 240 watts. 20 mS
Input Current
85 VAC at full rated load.
4.0
A
RMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor. Vin = 220 VAC, one cycle, 25C.
35
A
PK
Power Factor
Per EN61000-3-2.
0.95
W/VA
FEATURES
Currents Over 100 Amps
Fits 1U Chassis Height Constraints
No Minimum Load Requirement
Current Share Capabilities on All Outputs
Patented High-Efficiency Design
Meets European Power Factor Requirements for 2001
Excellent Load Transient Response
Designed to meet the stringent requirements of today's high-speed
datacom and telecom circuitry, Power-One's NET1 series is an excellent
compact power solution for low-voltage, high-current applications. The
NET1's high efficiency is achieved through the use of synchronous
rectification and a newly-patented "Soft Transition Forward Converter".
The NET1's rectification method lowers output losses, reduces system
cooling requirements (allowing greater power in a smaller package), and
eliminates minimum load requirements.
Advanced surface-mount design and packing technology reduce the
NET1's height to 1.35" (34.3mm) to fit in 1U applications. NET1's
high-performance active power factor circuitry meets EN61000-3-2
requirements for compliance with European Power Line Harmonic
Requirements for 2001. A multifunctional output terminal allows
connection to #8 ring lugs, 0.25" quick disconnects, cable connectors,
and PCB-mounted connectors.
1
Advanced Product
Release
Rev. 11/2000
NET1 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
TYP
MAX
UNITS
Efficiency
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.
80
%
Ripple and Noise
Full load, 20 MHz bandwidth.
See Model Selection Charts
Output Power
With 300 LFM forced air cooling. (Note 1)
240
Watts
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
0
%
Regulation
Varies by output. Total regulation includes: line changes over the specified.
See Model Selection Charts
input range, changes in load starting at 20% load and changing to 100% load.
Transient Response
Recovery time, to within 1% of initial set point due to a 10-100% load change,
500
S
1% max. deviation.
Turn-on Delay
Time required for initial output voltage stabilization.
2
Sec
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
20
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
TYP
MAX
UNITS
Overvoltage Protection
Overvoltage protection on all outputs.
Maximum + 0.5V
Unit latches off when overvoltage is detected.
AC input must be recycled to reset.
Overload Protection
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Overtemperature Protection
System shutdown due to excessive internal temperature, automatic reset.
Output Good
Open collector global Output Good signal. The signal activates when any of the outputs drop below 5%.
Input Power Fail Warning
Open collector signal. Time before regulation dropout due to loss of input
5
mS
power. May be used as independent PSOK signal in redundant applications.
Current Share
Available on all outputs. Accuracy of shared current with up to 6 parallel units.
10
%
Single wire current share.
Remote Sense
Available on all outputs. Total voltage compensation for cable losses with
500
mV
respect to the main output.
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
TYP
MAX
UNITS
Agency Approvals
UL1950.
CSA 22.2 NO. 234/950.
Approved
EN60950 (TV).
Dielectric Withstand Voltage
Input to output per EN60950.
2600
VDC
Electromagnetic Interference
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
B
Class
EN55022 / CISPR 22 Conducted.
B
ESD Susceptibility
Per EN61000-4-2, level 4.
8
kV
Radiated Susceptibility
Per EN61000-4-3, level 3.
10
V/M
EFT/Burst
Per EN61000-4-4, level 3.
2
kV
Input Transient Protection
Per EN61000-4-5, class 3.
Line to Line
1
kV
Line to Ground
2
Insulation Resistance
Input to output.
10
M
Advanced Product
Release
2
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
NET1 SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
TYP
MAX
UNITS
Altitude
Operating.
10k
ASL Ft.
Non-Operating.
40k
ASL Ft.
Operating Temperature
At 100% load
0
50
C
Storage Temperature
-40
85
C
Temperature Coefficient
0C to 70C (after 15-minute warmup).
0.02
0.05
%/C
Relative Humidity
Non-Condensing.
5
95
%RH
Shock
Peak acceleration.
20
G
PK
Vibration
Random vibration, 10 Hz to 2 kHz, 3 axis.
6
G
RMS
MECHANICAL
DESCRIPTION
NOTES
SIZE IMPACT
Metric Mounting
M4 x 0.7 mounting inserts: 2 mounting surfaces
Size
7.00" x 4.50" x 1.35"
(177.8mm x 114.3mm x 34.3mm)
3
Advanced Product
Release