ChipFind - документация

Электронный компонент: PFC375-4201

Скачать:  PDF   ZIP
1
PerFormanCe POWER PFC375
The PFC375 products of the PerFormanCe Power series
incorporate high performance midrange power, active Power
Factor Correction (PFC), and high reliability to meet varied
commercial and industrial requirements.
Providing tightly regulated DC power in a wide variety of single
and multiple output configurations, the PFC375 is designed to
provide full output power with only 300 Linear Feet per Minute
(LFM) forced-air cooling (factory installed fan optional). Other
features include remote sense, power fail, logic level inhibit, and
DC power good. Main channel current sharing is provided for
redundant applications. The PFC375 is available with SAE
mountings or optional metric mountings.
The PFC375 product line is approved to the latest international
regulatory standards, and displays the CE Mark.
FEATURES
Power Factor Correction (PFC) Meets EN61000-3-2
Fully Regulated Outputs
Main Output Remote Sense
Current Share, Power Fail, and Power Good Signals
Overtemperature, Overvoltage, and Overcurrent Protected
Available with Metric and SAE Mountings
Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5
Fan Output Voltage and Optional Fan
MULTIPLE OUTPUT MODEL SELECTION CHART -
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT
ADJUSTMENT
OUTPUT
PEAK OUTPUT
LINE
LOAD
RIPPLE & NOISE
INITIAL SETTING
VOLTAGE
RANGE
CURRENT (NOTE 1)
CURRENT (NOTE 2)
REGULATION
REGULATION
%p-p (NOTE 3)
ACCURACY
+5V
4.5V to 5.5V
3.5 - 40A
40A
0.4%
0.8%
1%
4.98V to 5.02V
PFC375-4000
+12V
11.3V to 12.6V
10A
16A
0.9%
0.9%
1%
11.9V to 12.1V
12V
11.3V to 12.6V
6A
6A
0.9%
0.9%
1%
11.9V to 12.1V
5V
Fixed
3A
3A
2%
2%
2.4%
4.9V to 5.1V
+5V
4.5V to 5.5V
3.5 - 40A
40A
0.4%
0.8%
1%
4.98V to 5.02V
PFC375-4001
+12V
11.3V to 12.6V
10A
16A
0.9%
0.9%
1%
11.9V to 12.1V
12V
11.3V to 12.6V
6A
6A
0.9%
0.9%
1%
11.9V to 12.1V
12V
11.0V to 16.0V
3A
3A
0.9%
0.9%
1%
11.9V to 12.1V
+5V
4.5V to 5.5V
3.5 - 40A
40A
0.4%
0.8%
1%
4.98V to 5.02V
PFC375-4002
+12V
11.3V to 12.6V
10A
16A
0.9%
0.9%
1%
11.9V to 12.1V
12V
11.3V to 12.6V
6A
6A
0.9%
0.9%
1%
11.9V to 12.1V
24V
22.0V to 28.0V
3A
3A
0.5%
0.8%
1%
23.8V to 24.2V
+5V
4.5V to 5.5V
3.5 - 40A
40A
0.4%
0.8%
1%
4.98V to 5.02V
PFC375-4004
+12V
11.3V to 12.6V
10A
16A
0.9%
0.9%
1%
11.9V to 12.1V
15V
14.2V to 15.8V
4A
4A
0.7%
0.7%
1%
14.9V to 15.1V
15V
14.2V to 15.8V
4A
4A
0.7%
0.7%
1%
14.9V to 15.1V
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT
ADJUSTMENT
MAXIMUM OUTPUT
LINE
LOAD
RIPPLE & NOISE
INITIAL SETTING
VOLTAGE
RANGE
CURRENT (NOTE 1)
REGULATION
REGULATION
%p-p (NOTE 2)
ACCURACY
PFC375-1012
12V
10.8V to 13.5V
30A
0.2%
0.8%
1%
11.94V to 12.06V
PFC375-1015
15V
12.0V to 17.0V
25A
0.2%
0.6%
1%
14.94V to 15.06V
PFC375-1024
24V
21.6V to 26.4V
15A
0.5%
0.8%
1%
23.88V to 24.12V
PFC375-1028
28V
25.2V to 30.8V
13.4A
0.5%
0.9%
0.9%
27.86V to 28.14V
PFC375-1048
48V
46.0V to 56.0V
7.8A
0.5%
1.0%
1%
47.52V to 48.48V
NOTES:
1) Output currents ratings are expressed with 300 LFM forced air.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
REV. 07/01
2
PerFormanCe POWER PFC375
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) -
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT
ADJUSTMENT
OUTPUT
PEAK OUTPUT
LINE
LOAD
RIPPLE & NOISE
INITIAL SETTING
VOLTAGE
RANGE
CURRENT (NOTE 1)
CURRENT (NOTE 2)
REGULATION
REGULATION
%p-p (NOTE 3)
ACCURACY
+5V
4.5V to 5.5V
3.5 - 40A
40A
0.4%
0.8%
1%
4.98V to 5.02V
PFC375-4005
+12V
11.3V to 12.6V
10A
16A
0.9%
0.9%
1%
11.9V to 12.1V
(Note 4)
24V
22.0V to 28.0V
3A
3A
0.5%
0.8%
1%
23.8V to 24.2V
24V
22.0V to 28.0V
3A
3A
0.5%
0.8%
1%
23.8V to 24.2V
+24V
21.5V to 26.4V
1 - 10A
10A
0.5%
0.8%
1%
23.8V to 24.2V
PFC375-4200
+5V
4.5V to 5.5V
10A
16A
0.4%
0.8%
1%
4.98V to 5.02V
12V
11.4V to 12.6V
4A
4A
0.5%
1%
1%
11.9V to 12.1V
12V
11.4V to 12.6V
4A
4A
0.5%
1%
1%
11.9V to 12.1V
+24V
21.5V to 26.4V
1 - 10A
10A
0.5%
0.8%
1%
23.8V to 24.2V
PFC375-4201
+5V
4.5V to 5.5V
10A
16A
0.4%
0.8%
1%
4.98V to 5.02V
15V
14.2V to 16.0V
4A
4A
0.5%
0.8%
1%
14.9V to 15.1V
15V
13.7V to 16.0V
4A
4A
0.5%
0.8%
1%
14.9V to 15.1V
+5V
4.5V to 5.5V
3.5 - 50A
50A
0.4%
0.8%
1%
4.98V to 5.02V
PFC375-4500
+12V
11.3V to 12.6V
10A
16A
0.9%
0.9%
1%
11.9V to 12.1V
12V
11.3V to 12.6V
6A
6A
0.9%
0.9%
1%
11.9V to 12.1V
5V
4.5V to 5.5V
3A
3A
2%
0.9%
1%
4.9V to 5.1V
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
2) Peak loads up to 450 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 450 Watts.
3) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
4) V3 and V4 may be series connected to obtain 48V.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Continuous input range.
85
264
VAC
Input Frequency
AC Input.
47
63
Hz
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated loads.
85
VAC
Hold-Up Time
Over full AC input voltage range at full rated load.
20
mS
Input Current
85 VAC at full rated load.
6
A
RMS
Input Protection
Non-user serviceable internally located AC input line fuse, F10A, 250V.
Inrush Surge Current
Internally limited by thermistor, one cycle, 25C.
110 VAC
35
A
PK
220 VAC
65
Power Factor
Per EN61000-3-2.
0.98
W/VA
Operating Frequency
Switching frequency of main transformer.
100
kHz
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full rated load, 110 VAC. Varies with distribution of loads among outputs.
68
%
Minimum Loads
Single output models.
0
Multiple output models, 5V main output only.
3.5
Amps
Multiple output models, 24V main output only.
1
Ripple and Noise
Full load, 20MHz bandwidth.
See Model Selection Charts
Output Power
300 LFM forced air cooling required for operation. See optional fan.
Continuous power, multiple output models.
375
Watts
Peak power, all models.
450
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
0
V
Regulation
Varies by output. Total regulation includes: line changes from 85-132 VAC or
See Model Selection Charts
170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100% load change,
1
mS
3% max. deviation. (Main output only on multi-output units).
Turn-On Delay
Time required for initial output voltage stabilization.
1
Sec
Turn-On Rise Time
Time required for output voltage to rise from 10% to 90%.
10
mS
3
PerFormanCe POWER PFC375
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on single output units and the main output only of multiple output units.
PFC375-30XX, PFC375-40XX, PFC375-45XX
6.0
6.4
PFC375-1012
13.5
15.5
PFC375-1015
17.0
19.5
PFC375-1024
27.0
30.7
V
PFC375-1028
30.8
35.0
PFC375-1048
60.0
70.0
PFC375-42XX
27.0
30.7
Overload Protection
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Overtemperature Protection
System shutdown due to excessive internal temperature, automatic reset.
Remote Sense
Total voltage compensation for cable losses with respect to the main output.
250
mV
Current Share
Accuracy of shared current with up to 6 parallel units.
10
%
Inhibit
TTL compatible logic signal will inhibit outputs by the application of a logic low signal.
An open circuit or external TTL high signal allows normal operation.
Input Power
TTL compatible logic signal. Time before regulation dropout due to
5
mS
Fail Warning
loss of input power at 110 VAC.
Power Good
TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal.
Fan Voltage
Provides 170 mA current to user-supplied fan, if fan option is not selected.
12
V
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL1950.
CSA 22.2 NO. 234/950.
Approved
EN60950 (TV).
Dielectric Withstand Voltage
Input to output.
2600
VDC
Electromagnetic Interference
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
B
Class
EN55022 / CISPR 22 Conducted.
B
ESD Susceptibility
Per EN61000-4-2, level 4.
8
kV
Radiated Susceptibility
Per EN61000-4-3, level 3.
10
V/M
EFT/Burst
Per EN61000-4-4, level 4.
4
kV
Input Transient Protection
Per EN61000-4-5 class 3.
Line to Line
1
kV
Line to Ground
2
Insulation Resistance
Input to output.
10
M
Leakage Current
Per EN60950, 264 VAC.
2.0
mA
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating.
10k
ASL Ft.
Non-Operating.
40k
ASL Ft.
Operating Temperature
At 100% load
0
50
C
Derate linearly above 50C by 2.5% per C.
At 50% load
0
70
C
Storage Temperature
-55
85
C
Forced Air Cooling
Forced air cooling of 300 LFM is required if the internal fan option is not specified.
Cooling air velocity is measured 1/4" above, at the middle of the chassis.
Airflow direction is from the input section to the output section.
Temperature Coefficient
0C to 70C (after 15-minute warmup).
0.02
0.05
%/C
Relative Humidity
Non-Condensing.
5
95
%RH
Shock
Operating: 103mS, 3 axis, Halfsine.
20
G
Non-operating: 103mS, 3 axis, Halfsine.
40
Vibration
Operating: 5-32
Hz
0.02
in (DA)
32-2000 Hz Sinusoidal
1
G
RMS
Non-operating:
6.15
G
RMS
4
OPTIONS
DESCRIPTION
NOTES
SIZE IMPACT
Fan
Add "F" as a suffix to the model number to order integral fan.
10.50" x 5.00" x 2.50"
(provides required 300 LFM of forced air cooling).
(266.7mm x 127.0mm x 63.5mm)
Metric Mounting
Add "M" as a suffix to the model number to order chassis with
9.00" x 5.00" x 2.50"
M4 x 0.7 mounting inserts.
(228.6mm x 127.0mm x 63.5mm)
PerFormanCe POWER PFC375
OVERALL SIZE: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm)
OVERALL LENGTH WITH FAN: 10.50" (266.7mm)
WEIGHT: 4.3 LBS (1.95 kg)
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW TERMINAL ON 0.375" (9.5mm) CENTERS
BUS BAR MAIN OUTPUT, E1 & E2, 10-32 SCREW TERMINAL
CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH