Input
VWS100ZH
60
65
70
75
80
85
90
95
10
20
30
40
50
60
70
80
90
100
LOAD %
EFFICIENCY %
EFF. (36v)
EFF. (48v)
EFF. (75v)
1
VWS DC/DC converters are direct replacement
converters for industry-standard full bricks.
Featuring a fixed-frequency design, the VWS offers
excellent transient response and predictable EMI
performance. The VWS can be combined with VWB
booster modules to provide increased power. VWS
converters use 100% surface-mount construction,
along with planar magnetics, and are fully compati-
ble with production board-washing processes.
100W Full Brick
Industry Standard
Footprint
Fixed Frequency
85C Case Operation
6-Sided Shielding
Superior Transient
Response
1500V Isolation
Optional Booster
Module
DESCRIPTION
FEATURES
VWS SERIES - 100 WATT
TECHNICAL SPECIFICATIONS
Turn-On Time
10 mS
Remote Shutdown
Positive Or Negative Logic
Remote Shutdown Reference
V
in
Negative
Switching Frequency
300 kHz
Isolation, Input - Output
1500 VDC
Isolation, Input - Case
1050 VDC
Isolation, Output - Case
500 VDC
Temperature Coefficient
0.2%/C
Case Temperature
Operating Range
-25 To +85C
Storage Range
-55 To +115C
Thermal Shutdown Range
90 To 100C
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
MTBF (Bellcore TR-NWT-000332)
2.1 x 10
6
hrs
Safety
UL, cUL, TUV
Weight (approx.)
6.0 oz
General
Voltage Range
24 VDC Nominal
18 - 36 VDC
48 VDC Nominal
36 - 72 VDC
Input Reflected Ripple Current
50 mA Pk-Pk
Undervoltage Lockout - Turn On / Turn Off
35 VDC / 32 VDC
Setpoint Accuracy
1%
Line Regulation V
in
Min. - V
in
Max., I
out
Rated
0.2% V
out
Load Regulation I
out
Min. - I
out
Max., V
in
Nom.
0.5% V
out
Remote Sense Headroom
0.5 VDC
Minimum Output Current
10 % I
out
Rated
Dynamic Regulation, Loadstep
25% I
out
Pk Deviation
8% V
out
Settling Time
500
s
Voltage Trim Range
10%
Current Limit Type
Hiccup
Current Limit Threshold Range, % of I
out
Rated
110 - 140%
Short Circuit Threshold Range, % of I
out
Rated
200%
OVP Trip Range
120 - 140% V
out
Nom.
OVP/UVP type
Self-Recovering
Output
Efficiency vs. Load (48V Input)
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
REV. 07/01
3
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and add
them to the model number. Example ordering options are located below the options table.
OPTION
SUFFIX
APPLICABLE SERIES
REMARKS
Negative Logic
N
HAS, HBD, HBS, HES, HLS, LES,
QBS, QES, QLS, TES, TQD
TTL Low Turns Module ON
TTL High Turns Module OFF
Lucent-Compatible Trim
T
HAS, HBD, HBS, HES, HLS, QBS,
QES, QLS
Terminal Strip
TS
XWS, XWD, XWT
Trim
1
IAS, LES
Enable
2
IAD, IAS, LES, SMS
Trim and Enable
3
IAS, LES
Current Share
4
SMS
Headerless
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180
(4.6mm)
0.110 (2.8mm) Pin Length
8
All Units (Except SMS)
0.150 (3.8mm) Pin Length
9
All Units (Except SMS)
0.24 (6.1mm) Horizontal Heatsink
1H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.24 (6.1mm) Vertical Heatsink
1V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.45 (11.4mm) Horizontal
Heatsink
2H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.45 (11.4mm) Vertical Heatsink
2V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.95 (24.1mm) Horizontal
Heatsink
3H
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
0.95 (24.1mm) Vertical Heatsink
3V
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM, TLD, and TKD Packages)
Includes Thermal Pad
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95 vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110 pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
OPTIONS