ChipFind - документация

Электронный компонент: BCR16PM-8

Скачать:  PDF   ZIP
Dimensions
Inches
Millimeters
H
0.126 0.008 Dia.3.2 0.2 Dia.
J
0.11
2.8
K
0.102
2.6
L
0.10
2.5
M
0.039
1.0
N
0.031
0.8
P
0.020
0.5
Dimensions
Inches
Millimeters
A
0.67
17.0
B
0.49 Min.
12.5 Min.
C
0.39
10.0
D
0.33
8.5
E
0.20
5.0
F
0.18
4.5
G
0.14
3.6
Description:
A triac is a solid state silicon
AC switch which may be gate
triggered from an off-state to an
on-state for either polarity of
applied voltage.
Features:
Full Molded Isolation Package
Glass Passivation
Low Off-state Leakage
1500 V
RMS
Isolation Voltage
UL Card
Excellent Surge Capability
Low On-state Voltage
Selected for Inductive Loads
Applications:
AC Switch
Motor Controls
Lighting
TV
SSR
Ordering Information:
Example: Select the complete
eight, nine or ten digit part number
you desire from the table - i.e.
BCR16PM-8 is a 400 Volt,
16 Ampere Triac.
V
DRM
Inductive
Type
Volts Code
Load*
BCR16PM
400
-8
L
600
-12
*For inductive load, add L.
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
Isolated Triac
16 Amperes/400-600 Volts
BCR16PM
Outline Drawing (Conforms to TO-220F)
T-79
C
5.2
H
D
1.2
A
E
J
K
P
G
B
N
M
L
L
F
CONNECTION DIAGRAM
OUTLINE DRAWING
T1 TERMINAL
T2 TERMINAL
GATE TERMINAL
Absolute Maximum Ratings,
T
a
= 25 C unless otherwise specified
Ratings
Symbol
BCR16PM-8
BCR16PM-12
Units
Repetitive Peak Off-state Voltage
V
DRM
400
600
Volts
Non-repetitive Peak Off-state Voltage
V
DSM
500
720
Volts
On-state Current, T
c
= 71C
I
T(RMS)
16
16
Amperes
Non-repetitive Peak Surge, One Cycle (60 Hz)
I
TSM
160
160
Amperes
I
2
t for Fusing, t = 8.3 msec
I
2
t
106.5
106.5
A
2
sec
Peak Gate Power Dissipation, 20 sec
P
GM
5
5
Watts
Average Gate Power Dissipation
P
G(avg)
0.5
0.5
Watts
Peak Gate Current
I
GM
2
2
Amperes
Peak Gate Voltage
V
GM
10
10
Volts
Storage Temperature
T
stg
-40 to 125
-40 to 125
C
Operating Junction Temperature
T
j
-40 to 125
-40 to 125
C
Isolation Voltage
V
iso
1500
1500
Volts
Weight
2
2
Grams
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR16PM
Isolated Triac
16 Amperes/400-600 Volts
T-80
Electrical and Thermal Characteristics,
T
j
= 25 C unless otherwise specified
Test Conditions (Trigger Mode)
BCR16PM
Characteristics
Symbol
V
D
R
L
R
G
T
j
Min.
Typ.
Max.
Units
Gate Parameters
DC Gate Trigger Current
MT2+ Gate+
I
FGT
I
6V
6
330
25C
30
mA
MT2+ Gate
I
RGT
I
6V
6
330
25C
30
mA
MT2 Gate
I
RGT
III
6V
6
330
25C
30
mA
DC Gate Trigger Voltage
MT2+ Gate+
V
FGT
I
6V
6
330
25C
1.5
Volts
MT2+ Gate
V
RGT
I
6V
6
330
25C
1.5
Volts
MT2 Gate
V
RGT
III
6V
6
330
25C
1.5
Volts
DC Gate Non-trigger Voltage
All
V
GD
1/2 V
DRM
125C
0.2
Volts
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Thermal Resistance, Junction-to-case
R
th(j-c)
3
C/W
Voltage Blocking State
I
DRM
Gate Open Circuited,
2
mA
Repetitive Off-state Current
V
D
= V
DRM
, T
j
= 125C
Current Conducting State
V
TM
T
c
= 25C,
1.6
Volts
Peak On-state Voltage
I
TM
= 25A
Critical Rate-of-rise of Commutating
(dv/dt)
c
V/ s
Off-state Voltage (Commutating dv/dt)
v
for inductive load (L)
(Switching)
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR16PM
Isolated Triac
16 Amperes/400-600 Volts
0
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(JUNCTION-TO-CASE)
CYCLES AT 60 Hz
TRANSIENT THERMAL IMPEDANCE, Z
th(j-c)
, (
C/WATT)
10
-1
10
0
10
2
10
3
10
1
10
2
1
2
3
4
5
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(JUNCTION-TO-AMBIENT)
CYCLES AT 60 Hz
TRANSIENT THERMAL IMPEDANCE, Z
th(j-a)
, (
C/WATT)
10
1
10
2
10
4
10
3
10
5
10
1
10
0
10
-1
10
2
10
3
NO FINS
10
-1
10
2
10
1
10
0
GATE CHARACTERISTICS
(I, II, III)
GATE CURRENT, I
G
, (mA)
GATE VOLTAGE, V
G
, (VOLTS)
10
2
10
1
10
3
10
4
V
GD
= 0.2V
V
GM
= 10V
V
GT
= 1.5V
I
GM
= 2A
P
GM
= 5W
P
G(avg)
= 0.5W
I
RGT I,
I
FGT I,
I
RGT III
0
40
80
120
160
200
MAXIMUM SURGE CURRENT
FOLLOWING RATED LOAD CONDITIONS
CYCLES AT 60 Hz
MAXIMUM PEAK SURGE CURRENT, I
TSM
, (AMPERES)
10
0
10
1
10
2
0
20
40
60
80
100
120
140
160
ALLOWABLE CASE TEMPERATURE
VS. RMS ON-STATE CURRENT
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
CASE TEMPERATURE, T
C
, (
C)
0
4
8
12
16
20
FOR AC CONTROL
THIS GRAPH NEARLY
APPLIES REGARDLESS
OF THE CONDUCTION
ANGLE
CONDUCTION
RESISTIVE,
INDUCTIVE
LOADS
0
5
10
15
20
25
30
35
40
MAXIMUM ON-STATE
POWER DISSIPATION
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
MAXIMUM POWER DISSIPATION, (WATTS)
0
20
12
18
14
8
2
6
10
16
4
360
CONDUCTION
RESISTIVE,
INDUCTIVE
LOADS
GATE TRIGGER CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, T
j
, (
C)
GATE TRIGGER CURRENT, (t
C)
GATE TRIGGER CURRENT, (25
C)
x 100%
-60
-20
20
60
100
140
-40
0
40
80
120
10
1
10
2
10
3
0.6
1.2
2.0
2.8
3.6
4.4
MAXIMUM ON-STATE
CHARACTERISTICS
INSTANTANEOUS ON-STATE VOLTAGE, V
T
, (VOLTS)
INSTANTANEOUS ON-STATE CURRENT, I
T
, (AMPERES)
10
0
10
1
10
2
10
3
T
j
= 25
o
C
T
j
= 125
o
C
0
20
40
60
80
100
120
140
160
ALLOWABLE AMBIENT TEMPERATURE
VS. RMS ON-STATE CURRENT
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
AMBIENT TEMPERATURE, T
a
, (
C)
0
0.8
0.4
1.2
2.0
1.6
2.4
3.2
2.8
NATURAL CONVECTION, NO FIN
ARBITRARY CONDUCTION ANGLE
RESISTIVE, INDUCTIVE LOADS
360
T-81
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR16PM
Isolated Triac
16 Amperes/400-600 Volts
GATE TRIGGER VOLTAGE
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, T
j
, (
C)
GATE TRIGGER VOLTAGE, (t
C)
GATE TRIGGER VOLTAGE, (25
C)
x 100%
-60
-20
20
60
100
140
-40
0
40
80
120
10
1
10
2
10
3
BREAKOVER VOLTAGE VS.
RATE OF RISE OF OFF-STATE VOLTAGE
(TYPICAL)
RATE OF RISE OF OFF-STATE VOLTAGE, dv/dt, (V/ s)
0
20
40
60
80
100
120
140
160
BREAKOVER VOLTAGE, (dv/dt = x V/
s)
BREAKOVER VOLTAGE, (dv/dt = 1V/
s)
x 100%
10
2
10
1
10
3
10
4
T
j
= 125
C
I QUADRANT
III QUADRANT
#1
#2
REPETITIVE PEAK OFF-STATE CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, T
j
, (
C)
-60
-20
20
60
100
140
-40
0
40
80
120
10
2
10
3
10
4
10
5
REPETITIVE PEAK OFF-STATE CURRENT, (t
C)
REPETITIVE PEAK OFF-STATE CURRENT, (25
C)
x 100%
BREAKOVER VOLTAGE
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, T
j
, (
C)
-60
-20
20
60
100
140
-40
0
40
80
120
0
20
40
60
80
100
120
140
160
BREAKOVER VOLTAGE, (t
C)
BREAKOVER VOLTAGE, (25
C)
x 100%
COMMUTATION CHARACTERISTICS
(TYPICAL)
RATE OF DECAY OF ON-STATE
COMMUTATING CURRENT, (A/ms)
10
0
10
1
10
2
10
3
10
0
10
1
10
2
10
3
CRITICAL RATE OF RISE OF
OFF-STATE COMMUTATING VOLTAGE, (V/
s)
T
j
= 125
o
C
I
T
= 4A
= 500 s
V
D
= 200v
f = 3Hz
MINIMUM
CHARAC-
TERISTICS
VALUE
V
D
t
(dv/dt)
c
VOLTAGE WAVEFORM
CURRENT WAVEFORM
I
T
t
(di/dt)
c
I QUADRANT
III QUADRANT
GATE TRIGGER CURRENT
VS. GATE CURRENT PULSE WIDTH
(TYPICAL)
GATE CURRENT PULSE WIDTH, t
w
, ( s)
GATE TRIGGER CURRENT, (t
w
)
GATE TRIGGER CURRENT, (DC)
x 100%
10
1
10
2
10
3
T
j
= 25
C
10
0
10
1
10
2
I
FGT I
I
RGT I
I
RGT III
GATE TRIGGER CHARACTERISTICS
TEST CIRCUITS
TEST PROCEDURE I
TEST PROCEDURE II
R
G
6V
6
A
V
R
G
6V
6
TEST PROCEDURE III
A
V
R
G
6V
6
A
V
T-82
Commutating
dv/dt, (dv/dt)
c
Commutating Voltage &
Part
V
DRM
(V/msec)
Current Waveform
Number
(Volts) Load Type Minimum
Test Condition
(Inductive Load)
BCR16PM-8L
400
L
10 Tj = 125C,
BCR16PM-12L 600
L
10 Rate of Decay
On-state
Commutating
Current
(di/dt)
c
= -8A/msec;
Peak Off-state
Voltage
V
D
= 400V
SUPPLY
VOLTAGE
(di / dt)
C
(dv / dt)
C
V
D
V
D
MAIN
CURRENT
MAIN
VOLTAGE
t
t
t