ChipFind - документация

Электронный компонент: PM200CSA060

Скачать:  PDF   ZIP
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
IntellimodTM Module
Three Phase
IGBT Inverter Output
200 Amperes/600 Volts
PM200CSA060
493
Description:
Powerex IntellimodTM Intelligent
Power Modules are isolated base
modules designed for power
switching applications operating
at frequencies to 20kHz. Built-in
control circuits provide optimum
gate drive and protection for the
IGBT and free-wheel diode
power devices.
Features:
Complete Output Power
Circuit
Gate Drive Circuit
Protection Logic
Short Circuit
Over Current
Over Temperature
Under Voltage
Applications:
Inverters
UPS
Motion/Servo Control
Power Supplies
Ordering Information:
Example: Select the complete
part number from the table below
-i.e. PM200CSA060 is a 600V,
200 Ampere IntellimodTM Intelligent
Power Module.
Type
Current Rating
V
CES
Amperes
Volts (x 10)
PM
200
60
Dimensions
Inches
Millimeters
A
5.31
0.04
135.0
1.0
B
4.74
0.02
120.5
0.5
C
4.33
0.04
110.0
1.0
D
4.27
10.5
E
3.76
0.02
95.5
0.5
F
3.29
83.5
G
2.01
51.0
H
1.602
40.68
J
1.54
39.0
K
1.37
34.7
L
1.33
33.7
M
1.02
26.0
N
0.95 +0.06/-0.0 24.1 +1.5/-0.0
P
0.85
21.5
Q
0.79
20.0
R
0.780
19.82
Dimensions
Inches
Millimeters
S
0.69
17.5
T
0.65
16.5
U
0.52
13.2
V
0.43
11.0
W
0.39
10.0
X
0.31
8.0
Y
0.285
7.25
Z
0.24
6.0
AA
0.22 Dia.
Dia. 5.5
AD
Metric M5
M5
AC
0.128
3.22
AD
0.10
2.6
AE
0.08
2.0
AF
0.07
1.8
AG
0.06
1.6
AH
0.02
0.5
Outline Drawing and Circuit Diagram
1.
2.
3.
4.
5.
6.
7.
8.
9.
V
V
V
V
V
V
V
10.
11.
12.
13.
14.
15.
16.
U
U
V
V
W
W
WPC
UPI
VPI
WPI
NC
NI
P
N
P
P
N
N
UPC
F
O
V
VPC
17.
18.
19.
NC
O
WF
O
VF
O
UF
AC
R
B
A
Y
Y
C
E
V
F
W
M
M
S
Z
D
Z
J
Q
Q
T
H
AC
W
W
W
AH
AH
G
10
12
N
V
B
P
W
U
Z
Y
Z
Y
AB - THD
(6 TYP.)
AA - DIA.
(4 TYP.)
3
AE (15 TYP.)
4
5 6 7 8
9 11
12
14 16 18
13 15 17 19
P
AF
AG
X
AD
N
L
K
U
2.54 MM DIA. (2 TYP.)
0.5 MM SQ. PIN
(19 TYP.)
V
V
CC
S
I
GND
GND
OUT
UPI
V
U
FO
UP
UPC
F
O
IN
V
CC
S
I
GND
GND
OUT
F
O
IN
V
CC
S
I
GND
GND
OUT
F
O
IN
V
V
FO
V
V
FO
VPI
V
VP
VPC
WPI
W
WP
WPC
V
CC
S
I
GND
GND
OUT
F
O
IN
V
CC
S
I
GND
GND
OUT
F
O
IN
U
N
V
CC
S
I
GND
GND
OUT
F
O
IN
V
V
W
N
V
NI
N
NC
TEMP
NC
F
O
P
U
V
W
N
NC
PM200CSA060
IntellimodTM Module
Three Phase IGBT Inverter Output
200 Amperes/600 Volts
494
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Absolute Maximum Ratings,
T
j
= 25
C unless otherwise specified
Characteristics
Symbol
PM200CSA060
Units
Power Device Junction Temperature
T
j
-20 to 150
C
Storage Temperature
T
stg
-40 to 125
C
Case Operating Temperature
T
C
-20 to 100
C
Mounting Torque, M5 Mounting Screws
--
17
in-lb
Mounting Torque, M5 Main Terminal Screws
--
17
in-lb
Module Weight (Typical)
--
920
Grams
Supply Voltage Protected by OC and SC (V
D
= 13.5 - 16.5V, Inverter Part)
V
CC(prot.)
400
Volts
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal
V
RMS
2500
Volts
Control Sector
Supply Voltage Applied between (V
UP1
-V
UPC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
)
V
D
20
Volts
Input Voltage Applied between (U
P
, V
P
, W
P
, U
N
, V
N
, W
N
)
V
CIN
20
Volts
Fault Output Supply Voltage (Applied between F
O
and V
C
)
V
FO
20
Volts
Fault Output Current
I
FO
20
mA
IGBT Inverter Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V)
V
CES
600
Volts
Collector Current,
I
C
200
Amperes
Peak Collector Current,
I
CP
400
Amperes
Supply Voltage (Applied between P - N)
V
CC
450
Volts
Supply Voltage, Surge (Applied between P - N)
V
CC(surge)
500
Volts
Collector Dissipation
P
C
595
Watts
495
PM200CSA060
IntellimodTM Module
Three Phase IGBT Inverter Output
200 Amperes/600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics,
T
j
= 25
C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Over Current Trip Level Inverter Part
OC
-20
C
T
125
C
310
400
--
Amperes
Short Circuit Trip Level Inverter Part
SC
-20
C
T
125
C
--
560
--
Amperes
Over Current Delay Time
t
off(OC)
V
D
= 15V
--
10
--
S
Over Temperature Protection
OT
Trip Level
111
118
125
C
OT
R
Reset Level
--
100
--
C
Supply Circuit Under Voltage Protection
UV
Trip Level
11.5
12.0
12.5
Volts
UV
R
Reset Level
--
12.5
--
Volts
Supply Voltage
V
D
Applied between V
UP1
-V
UPC
,
13.5
15
16.5
Volts
V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
Circuit Current
I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
--
40
55
mA
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
--
13
18
mA
Input ON Threshold Voltage
V
CIN(on)
Applied between
1.2
1.5
1.8
Volts
Input OFF Threshold Voltage
V
CIN(off)
U
P
, V
P
, W
P
, U
N
, V
N
, W
N
1.7
2.0
2.3
Volts
PWM Input Frequency
f
PWM
3- Sinusoidal
--
15
20
kHz
Fault Output Current
I
FO(H)
V
D
= 15V, V
FO
= 15V
--
--
0.01
mA
I
FO(L)
V
D
= 15V, V
FO
= 15V
--
10
15
mA
Minimum Fault Output Pulse Width
t
FO
V
D
= 15V
1.0
1.8
--
mS
PM200CSA060
IntellimodTM Module
Three Phase IGBT Inverter Output
200 Amperes/600 Volts
496
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics,
T
j
= 25
C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
IGBT Inverter Sector
Collector Cutoff Current
I
CEX
V
CE
= V
CEX
, T
j
= 25
C
--
--
1.0
mA
V
CE
= V
CEX
, T
j
= 125
C
--
--
10
mA
Diode Forward Voltage
V
FM
-I
C
= 200A, V
D
= 15V, V
CIN
= 15V
--
1.9
2.8
Volts
Collector-Emitter Saturation Voltage
V
CE(sat)
V
D
= 15V, V
CIN
= 0V, I
C
= 200A
--
1.8
2.7
Volts
V
D
= 15V, V
CIN
= 0V, I
C
= 200A,
--
1.75
2.63
Volts
T
j
= 125
C
Inductive Load Switching Times
t
on
0.4
0.8
2.0
S
t
rr
V
D
= 15V, V
CIN
= 0 ~ 15V
--
0.15
0.3
S
t
C(on)
V
CC
= 300V, I
C
= 200A
--
0.4
1.0
S
t
off
T
j
= 125
C
--
2.0
2.9
S
t
C(off)
--
0.6
1.2
S
Thermal Characteristics
Characteristic
Symbol
Condition
Min.
Typ.
Max.
Units
Junction to Case Thermal Resistance
R
th(j-c)Q
Each IGBT
--
--
0.21
C/Watt
R
th(j-c)D
Each FWDi
--
--
0.35
C/Watt
Contact Thermal Resistance
R
th(c-f)
Case to Fin Per Module,
--
--
0.018
C/Watt
Thermal Grease Applied
Recommended Conditions for Use
Characteristic
Symbol
Condition
Value
Units
Supply Voltage
V
CC
Applied across P-N Terminals
0 ~ 400
Volts
V
D
Applied between V
UP1
-V
UPC
,
15
1.5
Volts
V
N1
-V
NC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
Input ON Voltage
V
CIN(on)
Applied between
0 ~ 0.8
Volts
Input OFF Voltage
V
CIN(off)
U
P
, V
P
, W
P
, U
N,
V
N,
W
N
4.0 ~ V
D
Volts
PWM Input Frequency
f
PWM
Using Application Circuit
5 ~ 20
kHz
Minimum Dead Time
t
DEAD
Input Signal
2.5
S
497
PM200CSA060
IntellimodTM Module
Three Phase IGBT Inverter Output
200 Amperes/600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
0
1
2
3
SATURATION VOLTAGE
CHARACTERISTICS (TYPICAL)
COLLECTOR CURRENT, I
C
, (AMPERES)
SATURATION VOLTAGE V
CE(sat)
, (VOLTS)
0
100
300
200
V
D
= 15V
T
j
= 25
o
C
T
j
= 125
o
C
V
CIN
= 0V
0
1
2
COLLECTOR-EMITTER SATURATION
VOLTAGE CHARACTERISTICS (TYPICAL)
SUPPLY VOLTAGE, V
D
, (VOLTS)
COLLECTOR-EMITTER SATURATION VOLTAGE
V
CE(sat)
, (VOLTS)
20
3
0
22
18
16
14
12
I
C
= 200A
T
j
= 25
o
C
T
j
= 125
o
C
V
CIN
= 0V
OUTPUT CHARACTERISTICS
(TYPICAL)
COLLECTOR-EMITTER VOLTAGE, V
CE
, (VOLTS)
COLLECTOR CURRENT, I
C
, (AMPERES)
0
1
2
0
3
100
200
300
T
j
= 25
o
C
V
CIN
= 15V
V
D
= 17V
15
13

10
1
10
2
10
3
10
-1
COLLECTOR CURRENT, I
C
, (AMPERES)
SWITCHING TIMES, t
on
, t
off
, (
s)
SWITCHING TIME VS.
COLLECTOR CURRENT (TYPICAL)
t
on
10
0
10
1
t
off
V
CC
= 300V
V
D
= 15V
T
j
= 25
o
C
Tj
= 125
o
C
10
1
10
2
10
3
10
-1
COLLECTOR CURRENT, I
C
, (AMPERES)
SWITCHING TIMES, t
c(on)
, t
c(off)
, (
s)
SWITCHING TIME VS.
COLLECTOR CURRENT (TYPICAL)
t
c(on)
10
0
10
1
t
c(off)
V
CC
= 300V
V
D
= 15V
T
j
= 25
o
C
T
j
= 125
o
C
10
1
10
2
10
3
10
-2
EMITTER CURRENT, I
E
, (AMPERES)
REVERSE RECOVERY TIME, t
rr
, (
S)
REVERSE RECOVERY CURRENT VS.
COLLECTOR CURRENT (TYPICAL)
10
-1
10
0
V
CC
= 300V
V
D
= 15V
T
j
= 25
o
C
T
j
= 125
o
C
10
0
REVERSE RECOVERY CURRENT, I
rr
, (AMPERES)
10
1
10
2
I
rr
t
rr
0.4
1.2
2.4
10
1
DIODE FORWARD VOLTAGE, V
F
, (VOLTS)
DIODE FORWARD CURRENT, -I
F
, (AMPERES)
DIODE FORWARD CHARACTERISTICS
10
2
10
3
0.8
1.6
2.0
T
j
= 25
o
C
T
j
= 125
o
C
V
D
= 15V
10
20
60
100
OVER CURRENT TRIP LEVEL VS.
SUPPLY VOLTAGE (TYPICAL)
SUPPLY VOLTAGE, V
D
, (VOLTS)
OVER CURRENT TRIP LEVEL % (NORMALIZED)
12
0
14
16
18
20
T
j
= 25
o
C
0
120
40
80
0
40
60
120
OVER CURRENT TRIP LEVEL
TEMPERATURE DEPENDENCY (TYPICAL)
JUNCTION TEMPERATURE, T
j
, (
o
C)
OVER CURRENT TRIP LEVEL % (NORMALIZED)
0
50
100
150
-50
V
D
= 15V
100
80