AC POWER LINE TVS COMPONENT
APPLICATIONS
AC Power Mains
Module Lightning Protection
IEC COMPATIBILITY (EN61000-4)
61000-4-5 (Power): 8/20s - 1kA, L4 (Line-Line), 333A, L4 (Line-Ground)
FEATURES
4784 to 6920 Kilowatts Peak Pulse Power per Line (8/20s)
Glass Passivated Chip
Bidirectional Configuration
Easy Mounting to Printed Circuit Boards
Available in Voltage Types Ranging From: 90V to 240VAC
MECHANICAL CHARACTERISTICS
Epoxy Case
Weight 7.2 - 11.3 grams (Approximate)
Flammability Rating UL 94V-0
Marking: Logo & Device Marking Code
RADIAL LEADS
05186.R0 1/03
APPLICATION
AC POWER LINE PROTECTION
05186
. . . engineered solutions for the transient environmentTM
90V
AC
120V
AC
240V
AC
2
www.protekdevices.com
05186.R0 1/03
PAC-95
thru
PAC-240
DEVICE CHARACTERISTICS
MAXIMUM RATINGS @ 25C Unless Otherwise Specified
Peak Pulse Power Dissipation (t
p
=8/20s) - See Fig. 1
SYMBOL
VALUE
kilowatts
UNITS
4784 & 6920
P
PP
PARAMETER
-40 to +125
0
C
Storage Temperature
-40 to +125
0
C
T
J
Operating Temperature
T
STG
ELECTRICAL CHARACTERISTICS
PART
NUMBER
RATED
STAND-OFF
VOLTAGE
BREAKDOWN
VOLTAGE
MAXIMUM
CLAMPING
VOLTAGE
@ 8/20s
V
C
@ I
PP
TEMPERATURE
COEFFICIENT
OF V
(BR)
V
(BR)
%/C
PAC-95
PAC-130
PAC-240
135
202
380
157
214
400
299V @ 16kA
378V @ 16kA
692V @ 10kA
20
20
20
MAXIMUM
LEAKAGE
CURRENT
@V
WM
I
D
A
0.1
0.1
0.1
MIN
V
(BR)
VOLTS DC
@I
T
mA
1
1
1
95
130
240
V
WM
VOLTS AC
V
WM
VOLTS DC
3
www.protekdevices.com
05186.R0 1/03
PAC-95
thru
PAC-240
GRAPHS
0 25 50 75 100 125 150
T
L
- Lead Temperature - C
20
40
60
80
100
% Of Rated Power
Peak Pulse Power
8/20s
Average Power
FIGURE 3
POWER DERATING CURVE
0
I
PP
- Peak Pulse Current - % of I
PP
0 5 10 15 20 25 30
t - Time - s
0
20
40
60
80
100
120
TEST
WAVEFORM
PARAMETERS
t
f
= 8s
t
d
= 20s
t
f
Peak Value I
PP
e
-t
FIGURE 2
PULSE WAVE FORM
I
PP
/2
t
d
= t
0.1 1 10 100 1,000 10,000
t
d
- Pulse Duration - s
100
1000
10,000
100,000
P
PP
- Peak Pulse Power - kilowatts
FIGURE 1
PEAK PULSE POWER VS PULSE TIME
6920kW 8/20s
Waveform
4784kW 8/20s
Waveform
4
www.protekdevices.com
05186.R0 1/03
PAC-95
thru
PAC-240
COPYRIGHT ProTek Devices 2003
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC).
DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer's and that in furnishing engineering and
technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.
PACKAGE OUTLINE & DIMENSIONS
ProTek Devices
2929 South Fair Lane, Tempe, AZ 85282
Tel: 602-431-8101 Fax: 602-431-2288
E-Mail: sales@protekdevices.com
Web Site: www.protekdevices.com
06041 Rev 0 - 2/03
90VAC RADIAL LEAD PACKAGE OUTLINE
A
B
E
D
C
F
A
B
C
D
E
F
0.69
0.54
0.049
0.934 0.046
0.29
0.787
18.12
13.72
1.25
23.722 1.16
7.37
20.0
DIM
(Nominal)
(Nominal)
MILLIMETERS
INCHES
PACKAGE DIMENSIONS
(130 & 240 VAC Devices)
130 & 240 VAC RADIAL LEAD PACKAGE OUTLINE
A
B
C
D
E
F
0.49
0.49
0.05
0.79
0.25
0.92
12.5
12.45
1.27
20.1
6.35
23.37
DIM
(Nominal)
(Nominal)
MILLIMETERS
INCHES
PACKAGE DIMENSIONS
(90 VAC Device)
A
B
E
D
C
F