PO 48
www.recom-international.com
August 2002
POWERLINE - DC/DC-Converter
E-Series, 20W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
20 Watts Output Power
2:1 Wide Input Voltage Range
International Safety Standard
Approvals
Six-Sided Continuous Shield
High Efficiency up to 86%
Standard 50.8 x 40.6 x 10.2mm
Package
Fixed Switching Frequency
UL 1950 Component Recognised
Features
Part Number
Input
Output
Output
Input Current
Efficiency
Capacitive
Voltage
Voltage
Current
(see note 7)
(see note 8)
Load
max.
VDC
VDC
mA
mA
%
F
RP20-123.3SE
9-18
3.3
4000
1507
77
13000
RP20-1205SE
9-18
5
4000
2193
80
6800
RP20-1212SE
9-18
12
1670
2136
82
2200
RP20-1215SE
9-18
15
1330
2136
82
755
RP20-1205DE
9-18
5
2000
2193
80
3400
RP20-1212DE
9-18
12
833
2136
82
680
RP20-1215DE
9-18
15
666
2136
82
450
RP20-123.312TE
9-18
3.3 / 12
3000 / 300
1926
78
4700 / 220
RP20-123.315TE
9-18
3.3 / 15
3000 / 250
1959
78
4700 / 220
RP20-120512TE
9-18
5 / 12
2000 / 300
1885
80
4700 / 220
RP20-120515TE
9-18
5 / 15
2000 / 250
1919
80
4700 / 220
RP20-243.3SE
18-36
3.3
4000
743
78
13000
RP20-2405SE
18-36
5
4000
1082
81
6800
RP20-2412SE
18-36
12
1670
1054
83
2200
RP20-2415SE
18-36
15
1330
1054
83
755
RP20-2405DE
18-36
5
2000
1082
81
3400
RP20-2412DE
18-36
12
833
1054
83
680
RP20-2415DE
18-36
15
666
1041
84
450
RP20-243.312TE
18-36
3.3 / 12
3000 / 300
950
79
4700 / 220
RP20-243.315TE
18-36
3.3 / 15
3000 / 250
967
79
4700 / 220
RP20-240512TE
18-36
5 / 12
2000 / 300
931
81
4700 / 220
RP20-240515TE
18-36
5 / 15
2000 / 250
947
81
4700 / 220
RP20-483.3SE
36-75
3.3
4000
367
79
13000
RP20-4805SE
36-75
5
4000
543
82
6800
RP20-4812SE
36-75
12
1670
527
83
2200
RP20-4815SE
36-75
15
1330
527
83
755
RP20-4805DE
36-75
5
2000
541
81
3400
RP20-4812DE
36-75
12
833
514
85
680
RP20-4815DE
36-75
15
666
508
86
450
RP20-483.312TE
36-75
3.3 / 12
3000 / 300
468
80
4700 / 220
RP20-483.315TE
36-75
3.3 / 15
3000 / 250
477
80
4700 / 220
RP20-480512TE
36-75
5 / 12
2000 / 300
459
82
4700 / 220
RP20-480515TE
36-75
5 / 15
2000 / 250
467
82
4700 / 220
RP20-243.305DE
RP20-483.305DE, output 3.3V(3A))/5V(2A), for detailed spec. contact Recom
Selection Guide
12V, 24V and 48V Input Types
PO 49
www.recom-international.com
August 2002
Specifications
(typical at nominal input and 25C unless otherwise noted)
Output Power
20W max.
Voltage Accuracy (full Load and nominal Vin)
Single & Dual
2%
Triple 3.3V / 5V
2%
Auxiliary
5%
Voltage Adjustability
10%
Minimum Load (see note 1)
10% of FL
Line Regulation (LL-HL at FL)
Single & Dual
0.2%
Triple 3.3V / 5V
1%
Auxiliary
5%
Load Regulation (10% to 100% FL)
Single
0.5%
Dual
3%
Triple 3.3V / 5V
2%
Auxiliary
5%
Cross Regulation (see note 2)
Dual
5%
Triple 3.3V / 5V
2%
Auxiliary
5%
Ripple and Noise (20MHz BW)
Single
75mVp-p
Dual
100mVp-p
Triple 3.3V / 5V
50mVp-p
Auxiliary
1% of Vout
Temperature Coefficient
0.02% / C max.
Transient Response Recovery Time (25% load step change)
500sec
Over Voltage (zener diode clamp)
3.3V output
3.9V
5V output
6.2V
12V output
15V
15V output
18V
Short Circuit Protection
Hiccup,automatic recovery
continued on next page
RP20-4805SE: Derating & Efficiency Curves
125
75
50
25
0
100
Ambient Temperature Range (C)
-40 -25 -10 0
50 60 70 80 90 100
Output Power (%)
Natural Convection
85
77
76
74
Input Voltage (V)
36
Efficiency (%)
78
79
80
81
82
83
84
75
40
55
60
45
50
70
75
65
85
74
70
60
Output Load (A)
0.5
Efficiency (%)
76
78
80
81
82
83
84
65
1
1.5
2
2.5
4
3
3.5
RP20-4805SE Efficiency vs Output Load
RP20-4805SE Efficiency vs Input Voltage
RP20-4805SE Derating Curve
125
75
50
25
0
100
Ambient Temperature Range (C)
-40 -25 -10 0
50 60 70 80 90 100
Output Power (%)
Natural Convection
RP20-4805SE Derating Curve with Heat Sink
(see note 3)
POWERLINE - DC/DC-Converter
E-Series, 20W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
PO 50
www.recom-international.com
August 2002
Specifications continued
(typical at nominal input and 25C unless otherwise noted)
Input Voltage Range
12V types nominal input
9-18VDC
24V types nominal input
18-36VDC
48V types nominal input
36-75VDC
Input Filter
Pi Type
Input Surge Voltage (100 ms max.)
12V input
36VDC
24V input
50VDC
48V input
100VDC
Input Reflected Ripple (see note 3)
Nominal Vin and ful load
25mAp-p
Start Up Time (nominal Vin and constant resistor load)
20ms typ.
Remote ON/OFF (see note 4)
DC-DC ON
Open or 3.5V < Vr < 12V
DC-DC OFF
Short or 0V < Vr < 1.2V
Remote off input current
20mA
Efficiency
See ,,Selection Guide" table
Isolation Voltage
1600VDC
Isolation Resistance
10
9
Isolation Capacitance
300pF max.
Switching Frequency
300kHz typ.
Approved to Safety Standards
UL 1950, EN60950
Case Material
Nickel-coated copper
Base Material
Non-conducted black plastic
Potting Material
Epoxy (UL94-V0)
Weight
48g
Dimensions
50.8 x 40.6 x 10.2 mm
MTBF (see note 5)
1.928 x 10
6
Hours
Operating Temperature Range
-40C to +85C (with derating)
Maximum Case Temperature
+100C
Storage Temperature Range
55C to +105C
Thermal Impedance (see note 6)
Natural convection
10C/Watt
Thermal Shock
MIL-STD-810D
Vibration
10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Conducted Emissions
EN55022
Level A
Radiated Emissions
EN55022
Level A
Conducted Immunity
EN61000-4-6
Perf. Criteria 2
Radiated Immunity
EN61000-4-3
Perf. Criteria 2
Surge
EN61000-4-5
Perf. Criteria 2
Fast Transient
EN61000-4-4
Perf. Criteria 2
ESD
EN61000-4-2
Perf. Criteria 2
Notes:
1.
The RP20 series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage
these devices, however they may not meet all listed specification.
2.
Cross regulation: Dual output Asymmetrical load 25% to 100% full load.
Triple output 3.3V/ 5V 100% load and one of auxiliary 100% load, other auxiliary load change from 25% to 100% load.
3.
Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4.
The ON/OFF control pin voltage is referenced to negative input.
5.
BELLCORE TR-NWT-00332. Case l: 50% Stress, Temperature at 40C. (Ground fixed and controlled environment).
6.
Heat sink is optional and P/N: 7G-0011A. Operation temperature range please see curve.
7.
Maximum value at nominal input voltage and full load.
8.
Typical value at nominal input voltage and full load.
9.
The RP20-243.305DE and RP20-483.305DE are safety approval pending.
POWERLINE - DC/DC-Converter
E-Series, 20W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)
PO 51
www.recom-international.com
August 2002
Pin Pitch Tolerance 0.35 mm
Package Style and Pinning (mm)
5
50.10
5.10
15.20
17.80
40.60
2
4
45.70
12.70
10.20
17.80
10.20
8
7
6
Bottom
View
1
10.20
dia.
1.0
5.6
Pin Connections
Pin #
Single
Dual
Triple
1
+Vin
+Vin
+Vin
2
Vin
Vin
Vin
4
Ctrl
Ctrl
Ctrl
5
No Pin
+Vout
+Aux
6
+Vout
Common
+3.3V / +5V
7
Vout Vout
Common
8
Trim
Trim
Aux
External Output Trimming
Trim
Up
Trim
Down
Single
Dual
7
7
8
8
6
5
POWERLINE - DC/DC-Converter
E-Series, 20W, 1.6 kV Isolation, 2:1 Wide Input Range (Single, Dual & Triple Output)