Direct RDRAM
TM
Page -1
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
October 2000
Version 1.11
Direct RDRAM
TM
256K x 16/18 bit x 32s banks
128/144Mbit RDRAM(A-die)
Direct RDRAM
TM
Page 0
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Change History
Version 1.0 ( July 1999 ) - Preliminary
* Based on the Rambus Datasheet 1.0ver
Version 1.01 ( October 1999 )
Page No.
Change Description
1
- Delete the part numbers of low power.
12
- Add the Tj value from TBD to Max. 100
C @ Table 10
14
- Add the
JC
value from TBD to 0.2
C/Watt @ Table 12
16
- Add the current values for 356MHz and 300MHz RDRAM device
32
- Add the data of CNFGA Register @ Figure31
33
- Add the data of CNFGB Register @ Figure32 and correct the CORG4..0 field of CNFGB register
Version 1.02 ( January 2000 )
Page No.
Change Description
* Change the part number of RDRAM Component according to New Code System since '00.Jan.1st
12
- Reduce swing of V
IH,CMOS
& V
IL,CMOS
from
"
0.5V
CMOS
0.6V
"
to
"
0.5V
CMOS
0.4V
"
- Relax tS1 from 1.0ns to
"
1.25ns
"
( But, Keep tH1 as 1.0ns)
Version 1.11 ( October 2000 )
Page No.
Change Description
* Based on the Rambus 1.11ver. 128/144Mb(32s bank) RDRAM Datasheet
5
- Comment that
"
Sense Amps 0, 15, 16, and 31 are not shared
"
.
6
- Change to
"
The COLM packet is associated with the COLC packet from at least t
RTR
earlier.
"
12
In Table 10 ( Electrical Conditions )
- Change V
CMOS
parameter for 2.5V controller to V
DD
and add footnote to it.
- Relax V
CM,MIN/MAX
parameter to 1.3V/1.8V
- Relax V
CIS,CTM,MAX
parameter to 1.0V
- Relax V
CIS,CFM,MIN/MAX
parameter 0.225V/1.0V
- Remove V
TERM
, V
X
parameters
- Add footnote to V
DIH
parameter
- Add footnote to V
IL,CMOS,MIN
and V
IH,CMOS,MAX
14
- Change
JC
value to 0.5
C/Watt
- Add footbote to measurement condition.
16
- Add I
DD,REFRESH
paramenter .
- Relax I
DD,PDN
value to 5000uA
- Modify the descriptions under the second column
"
RDRAM blocks consuming power
"
- Add the table
"
Supply Current at Initialization
"
17
- Modify
C
I
paramter description.
- Modify footnote to C
I
for RSL paramenter in table 17.
Direct RDRAM
TM
Page 1
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Overview
The Rambus Direct RDRAMTM is a general purpose high-
performance memory device suitable for use in a broad
range of applications including computer memory, graphics,
video, and any other application where high bandwidth and
low latency are required.
The 128/144-Mbit Direct Rambus DRAMs (RDRAM
) are
extremely high-speed CMOS DRAMs organized as 8M
words by 16 or 18 bits. The use of Rambus Signaling Level
(RSL) technology permits 600MHz to 800MHz transfer
rates while using conventional system and board design
technologies. Direct RDRAM devices are capable of
sustained data transfers at 1.25 ns per two bytes (10ns per
sixteen bytes).
The architecture of the Direct RDRAMs allows the highest
sustained bandwidth for multiple, simultaneous randomly
addressed memory transactions. The separate control and
data buses with independent row and column control yield
over 95% bus efficiency. The Direct RDRAM's 32 banks
support up to four simultaneous transactions.
System oriented features for mobile, graphics and large
memory systems include power management, byte masking,
and x18 organization. The two data bits in the x18 organiza-
tion are general and can be used for additional storage and
bandwidth or for error correction.
Features
Highest sustained bandwidth per DRAM device
- 1.6GB/s sustained data transfer rate
- Separate control and data buses for maximized
efficiency
- Separate row and column control buses for
easy scheduling and highest performance
- 32 banks: four transactions can take place simul-
taneously at full bandwidth data rates
Low latency features
- Write buffer to reduce read latency
- 3 precharge mechanisms for controller flexibility
- Interleaved transactions
Advanced power management:
- Direct RDRAM operates from a 2.5 volt supply
- Multiple low power states allows flexibility in power
consumption versus time to transition to active state
- Power-down self-refresh
Organization: 1Kbyte pages and 32 banks, x 16/18
- x18 organization allows ECC configurations or
increased storage/bandwidth
- x16 organization for low cost applications
Uses Rambus Signaling Level (RSL) for up to 800MHz
operation
The 128/144-Mbit Direct RDRAMs are offered in a CSP
horizontal package suitable for desktop as well as low-
profile add-in card and mobile applications.
Key Timing Parameters/Part Numbers
a.
"
32s
"
- 32 banks which use a
"
split
"
bank architecture.
b.
"
N
"
- normal package,
"
M
"
- mirrored package.
c.
"
C
"
- RDRAM core uses normal power self refresh.
Figure 1: Direct RDRAM CSP Package
Organization
Speed
Part Number
Bin
I/O
Freq.
MHz
t
RAC
(Row
Access
Time) ns
256Kx16x32s
a
-CK8
800
45
K4R271669A-N
b
(M)C
c
K8
-CK7
711
45
K4R271669A-N(M)CK7
-CG6
600
53.3
K4R271669A-N(M)CG6
256Kx18x32s
a
-CK8
800
45
K4R441869A-N(M)CK8
-CK7
711
45
K4R441869A-N(M)CK7
-CG6
600
53.3
K4R441869A-N(M)CG6
a. Normal Package
b. Mirrored Package
K4R
xxxx
69A-
N
xxx
SAMSUNG 001
M
K4R
xxxx
69A-
M
xxx
SAMSUNG 001
Direct RDRAM
TM
Page 2
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
COL
ROW
COL
ROW
Pinouts and Definitions
Center-Bonded Devices
These tables shows the pin assignments of the center-bonded
RDRAM package. The top table is for the normal package,
and bottom table is for the mirrored package. The mechan-
ical dimensions of this package are shown in a later section.
Refer to Section "Center-Bonded uBGA Package" on page
18.
Table 1-1: a. Center-Bonded Device (top view for normal package)
12
GND
VDD
VDD
GND
11
10
DQA7
DQA4
CFM
CFMN
RQ5
RQ3
DQB0
DQB4
DQB7
9
GND
VDD
GND
GNDa
VDD
GND
VDD
VDD
GND
8
CMD
DQA5
DQA2
VDDa
RQ6
RQ2
DQB1
DQB5
SIO1
7
6
5
SCK
DQA6
DQA1
VREF
RQ7
RQ1
DQB2
DQB6
SIO0
4
VCMOS
GND
VDD
GND
GND
VDD
GND
GND
VCMOS
3
DQA8
*
DQA3
DQA0
CTMN
CTM
RQ4
RQ0
DQB3
DQB8
*
2
1
GND
VDD
VDD
GND
A
B
C
D
E
F
G
H
J
Table 1-2: a. Center-Bonded Device (top view for mirrored package)
12
GND
VDD
VDD
GND
11
10
DQA8
*
DQA3
DQA0
CTMN
CTM
RQ4
RQ0
DQB3
DQB8
*
9
VCMOS
GND
VDD
GND
GND
VDD
GND
GND
VCMOS
8
SCK
DQA6
DQA1
VREF
RQ7
RQ1
DQB2
DQB6
SIO0
7
6
5
CMD
DQA5
DQA2
VDDa
RQ6
RQ2
DQB1
DQB5
SIO1
4
GND
VDD
GND
GNDa
VDD
GND
VDD
VDD
GND
3
DQA7
DQA4
CFM
CFMN
RQ5
RQ3
DQB0
DQB4
DQB7
2
1
GND
VDD
VDD
GND
A
B
C
D
E
F
G
H
J
For normal package, pin #1(ROW 1, COL A) is
located at the A1 position on the top side and the A1
position is marked by the marker
"
"
.
For mirrored package, pin #1(ROW 1, COL A) is
located at the A1 postion on the top side and the A1
position is marked by the alphabet
"
M
"
.
Chip
Top View
* DQA8/DQB8 are just used for 144Mb RDRAM.
These two pins are NC(No Connection) in 128Mb
RDRAM.
b.
Top marking
example of normal package
K4R
xxxx
69A-
N
xxx
SAMSUNG 001
M
K4R
xxxx
69A-
M
xxx
SAMSUNG 001
b. Top marking example
of mirrored package
Direct RDRAM
TM
Page 3
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Table 2: Pin Description
Signal
I/O
Type
# of
Pins
Description
SIO1,SIO0
I/O
CMOS
a
2
Serial input/output. Pins for reading from and writing to the control regis-
ters using a serial access protocol. Also used for power management.
CMD
I
CMOS
a
1
Command input. Pins used in conjunction with SIO0 and SIO1 for reading
from and writing to the control registers. Also used for power manage-
ment.
SCK
I
CMOS
a
1
Serial clock input. Clock source used for reading from and writing to the
control registers
V
DD
10
Supply voltage for the RDRAM core and interface logic.
V
DDa
1
Supply voltage for the RDRAM analog circuitry.
V
CMOS
2
Supply voltage for CMOS input/output pins.
GND
13
Ground reference for RDRAM core and interface.
GNDa
1
Ground reference for RDRAM analog circuitry.
DQA8..DQA0
I/O
RSL
b
9
Data byte A. Nine pins which carry a byte of read or write data between
the Channel and the RDRAM. DQA8 is not used (no connection) by
RDRAMs with a x16 organization.
CFM
I
RSL
b
1
Clock from master. Interface clock used for receiving RSL signals from
the Channel. Positive polarity.
CFMN
I
RSL
b
1
Clock from master. Interface clock used for receiving RSL signals from
the Channel. Negative polarity
V
REF
1
Logic threshold reference voltage for RSL signals
CTMN
I
RSL
b
1
Clock to master. Interface clock used for transmitting RSL signals to the
Channel. Negative polarity.
CTM
I
RSL
b
1
Clock to master. Interface clock used for transmitting RSL signals to the
Channel. Positive polarity.
RQ7..RQ5 or
ROW2..ROW0
I
RSL
b
3
Row access control. Three pins containing control and address informa-
tion for row accesses.
RQ4..RQ0 or
COL4..COL0
I
RSL
b
5
Column access control. Five pins containing control and address informa-
tion for column accesses.
DQB8..
DQB0
I/O
RSL
b
9
Data byte B. Nine pins which carry a byte of read or write data between
the Channel and the RDRAM. DQB8 is not used (no connection) by
RDRAMs with a x16 organization.
Total pin count per package
62
a. All CMOS signals are high-true; a high voltage is a logic one and a low voltage is logic zero.
b. All RSL signals are low-true; a low voltage is a logic one and a high voltage is logic zero.
Direct RDRAM
TM
Page 4
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Figure 2: 128/144 Mbit(256K x16/18 x32s) Direct RDRAM Block Diagram
Bank 31
DQA8..DQA0
1
:
8

D
e
m
u
x
8
:
1

M
u
x
W
r
i
t
e

B
u
f
f
e
r
1
:
8

D
e
m
u
x
W
r
i
t
e

B
u
f
f
e
r
8
:
1

M
u
x
Bank 30
Bank 29
Bank 18
Bank 17
Bank 16
Bank 15
Bank 14
Bank 13
Bank 1
Bank 0
S
A
m
p
1
/
2
DQB8..DQB0
9
1:8 Demux
1:8 Demux
Packet Decode
9
5
3
ROW2..ROW0
COL4..COL0
CTM CTMN
CFM CFMN
2
SCK,CMD
RCLK
TCLK
Control Registers
DC
COP
C
BC
MA
MB
DX
XOP
BX
DR
R
ROP
BR
8
8
6
5
5
5
5
5
6
9
5
5
11
AV
M
S
Write
Buffer
Match
Match
Mux
Match
DEVID
512x64x144
Internal DQB Data Path
Column Decode & Mask
72
9
9
72
9
DM
REFR
Row Decode
Mux
ACT
RD, WR
Power Modes
DRAM Core
Mux
XOP Decode
PREX
PREC
9
9
9
9
72
9
9
9
PRER
COLX
COLC
COLM
2
SIO0,SIO1
Sense Amp
Internal DQA Data Path
Packet Decode
ROWA
ROWR
RCLK
RCLK
R
C
L
K
T
C
L
K
R
C
L
K
T
C
L
K
RQ7..RQ5 or
RQ4..RQ0 or
S
A
m
p
0
/
1
S
A
m
p
0
S
A
m
p
1
4
/
1
5
S
A
m
p
1
5
S
A
m
p
1
3
/
1
4
S
A
m
p
1
6
/
1
7
S
A
m
p
1
7
/
1
8
S
A
m
p
1
6
S
A
m
p
2
9
/
3
0
S
A
m
p
3
0
/
3
1
S
A
m
p
3
1
32x72
S
A
m
p
1
/
2
72
S
A
m
p
0
/
1
S
A
m
p
0
S
A
m
p
1
4
/
1
5
S
A
m
p
1
5
S
A
m
p
1
3
/
1
4
S
A
m
p
1
6
/
1
7
S
A
m
p
1
7
/
1
8
S
A
m
p
1
6
S
A
m
p
2
9
/
3
0
S
A
m
p
3
0
/
3
1
S
A
m
p
3
1
32x72
32x72
Bank 2












Direct RDRAM
TM
Page 5
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
General Description
Figure 2 is a block diagram of the 128/144Mbit Direct
RDRAM. It consists of two major blocks: a
"
core
"
block
built from banks and sense amps similar to those found in
other types of DRAM, and a Direct Rambus interface block
which permits an external controller to access this core at up
to 1.6GB/s.
Control Registers:
The CMD, SCK, SIO0, and SIO1
pins appear in the upper center of Figure 2. They are used to
write and read a block of control registers. These registers
supply the RDRAM configuration information to a
controller and they select the operating modes of the device.
The nine bit REFR value is used for tracking the last
refreshed row. Most importantly, the five bit DEVID speci-
fies the device address of the RDRAM on the Channel.
Clocking:
The CTM and CTMN pins (Clock-To-Master)
generate TCLK (Transmit Clock), the internal clock used to
transmit read data. The CFM and CFMN pins (Clock-From-
Master) generate RCLK (Receive Clock), the internal clock
signal used to receive write data and to receive the ROW and
COL pins.
DQA,DQB Pins:
These 18 pins carry read (Q) and write
(D) data across the Channel. They are multiplexed/de-multi-
plexed from/to two 72-bit data paths (running at one-eighth
the data frequency) inside the RDRAM.
Banks:
The 16Mbyte core of the RDRAM is divided into
thirty two 0.5Mbyte banks, each organized as 512 rows, with
each row containing 64 dualocts, and each dualoct
containing 16 bytes. A dualoct is the smallest unit of data
that can be addressed.
Sense Amps:
The RDRAM contains 34 sense amps. Each
sense amp consists of 512 bytes of fast storage (256 for DQA
and 256 for DQB) and can hold one-half of one row of one
bank of the RDRAM. The sense amp may hold any of the
512 half-rows of an associated bank. However, each sense
amp is shared between two adjacent banks of the RDRAM
(except for sense amps 0, 15, 16, and 31). This introduces the
restriction that adjacent banks may not be simultaneously
accessed.
RQ Pins:
These pins carry control and address informa-
tion. They are broken into two groups. RQ7..RQ5 are also
called ROW2..ROW0, and are used primarily for controlling
row accesses. RQ4..RQ0 are also called COL4..COL0, and
are used primarily for controlling column accesses.
ROW Pins:
The principle use of these three pins is to
manage the transfer of data between the banks and the sense
amps of the RDRAM. These pins are de-multiplexed into a
24-bit ROWA (row-activate) or ROWR (row-operation)
packet.
COL Pins:
The principle use of these five pins is to
manage the transfer of data between the DQA/DQB pins and
the sense amps of the RDRAM. These pins are de-multi-
plexed into a 23-bit COLC (column-operation) packet and
either a 17-bit COLM (mask) packet or a 17-bit COLX
(extended-operation) packet.
ACT Command:
An ACT (activate) command from an
ROWA packet causes one of the 512 rows of the selected
bank to be loaded to its associated sense amps (two 256 byte
sense amps for DQA and two for DQB).
PRER Command:
A PRER (precharge) command from
an ROWR packet causes the selected bank to release its two
associated sense amps, permitting a different row in that
bank to be activated, or permitting adjacent banks to be acti-
vated.
RD Command:
The RD (read) command causes one of
the 64 dualocts of one of the sense amps to be transmitted on
the DQA/DQB pins of the Channel.
WR Command:
The WR (write) command causes a
dualoct received from the DQA/DQB data pins of the
Channel to be loaded into the write buffer. There is also
space in the write buffer for the BC bank address and C
column address information. The data in the write buffer is
automatically retired (written with optional bytemask) to one
of the 64 dualocts of one of the sense amps during a subse-
quent COP command. A retire can take place during a RD,
WR, or NOCOP to another device, or during a WR or
NOCOP to the same device. The write buffer will not retire
during a RD to the same device. The write buffer reduces the
delay needed for the internal DQA/DQB data path turn-
around.
PREC Precharge:
The PREC, RDA and WRA
commands are similar to NOCOP, RD and WR, except that a
precharge operation is performed at the end of the column
operation. These commands provide a second mechanism
for performing precharge.
PREX Precharge:
After a RD command, or after a WR
command with no byte masking (M=0), a COLX packet may
be used to specify an extended operation (XOP). The most
important XOP command is PREX. This command provides
a third mechanism for performing precharge.
Direct RDRAM
TM
Page 6
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Packet Format
Figure 3 shows the formats of the ROWA and ROWR
packets on the ROW pins. Table 3 describes the fields which
comprise these packets. DR4T and DR4F bits are encoded to
contain both the DR4 device address bit and a framing bit
which allows the ROWA or ROWR packet to be recognized
by the RDRAM.
The AV (ROWA/ROWR packet selection) bit distinguishes
between the two packet types. Both the ROWA and ROWR
packet provide a five bit device address and a five bit bank
address. An ROWA packet uses the remaining bits to
specify a nine bit row address, and the ROWR packet uses
the remaining bits for an eleven bit opcode field. Note the
use of the
"
RsvX
"
notation to reserve bits for future address
field extension.
Figure 3 also shows the formats of the COLC, COLM, and
COLX packets on the COL pins. Table 4 describes the fields
which comprise these packets.
The COLC packet uses the S (Start) bit for framing. A
COLM or COLX packet is aligned with this COLC packet,
and is also framed by the S bit.
The 23 bit COLC packet has a five bit device address, a five
bit bank address, a six bit column address, and a four bit
opcode. The COLC packet specifies a read or write
command, as well as some power management commands.
The remaining 17 bits are interpreted as a COLM (M=1) or
COLX (M=0) packet. A COLM packet is used for a COLC
write command which needs bytemask control. The COLM
packet is associated with the COLC packet from at least
t
RTR
earlier. An COLX packet may be used to specify an
independent precharge command. It contains a five bit
device address, a five bit bank address, and a five bit opcode.
The COLX packet may also be used to specify some house-
keeping and power management commands. The COLX
packet is framed within a COLC packet but is not otherwise
associated with any other packet.
Table 3: Field Description for ROWA Packet and ROWR Packet
Field
Description
DR4T,DR4F
Bits for framing (recognizing) a ROWA or ROWR packet. Also encodes highest device address bit.
DR3..DR0
Device address for ROWA or ROWR packet.
BR4..BR0
Bank address for ROWA or ROWR packet. RsvB denotes bits ignored by the RDRAM.
AV
Selects between ROWA packet (AV=1) and ROWR packet (AV=0).
R8..R0
Row address for ROWA packet. RsvR denotes bits ignored by the RDRAM.
ROP10..ROP0
Opcode field for ROWR packet. Specifies precharge, refresh, and power management functions.
Table 4: Field Description for COLC Packet, COLM Packet, and COLX Packet
Field
Description
S
Bit for framing (recognizing) a COLC packet, and indirectly for framing COLM and COLX packets.
DC4..DC0
Device address for COLC packet.
BC4..BC0
Bank address for COLC packet. RsvB denotes bits reserved for future extension (controller drives 0 ' s).
C5..C0
Column address for COLC packet. RsvC denotes bits ignored by the RDRAM.
COP3..COP0
Opcode field for COLC packet. Specifies read, write, precharge, and power management functions.
M
Selects between COLM packet (M=1) and COLX packet (M=0).
MA7..MA0
Bytemask write control bits. 1=write, 0=no-write. MA0 controls the earliest byte on DQA8..0.
MB7..MB0
Bytemask write control bits. 1=write, 0=no-write. MB0 controls the earliest byte on DQB8..0.
DX4..DX0
Device address for COLX packet.
BX4..BX0
Bank address for COLX packet. RsvB denotes bits reserved for future extension (controller drives 0' s).
XOP4..XOP0
Opcode field for COLX packet. Specifies precharge, I
OL
control, and power management functions.
Direct RDRAM
TM
Page 7
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Figure 3: Packet Formats
CTM/CFM
COL4
COL3
COL2
COL1
COL0
T
8
T
9
T
10
T
11
T
12
T
13
T
14
T
15
T
8
T
9
T
10
T
11
T
0
T
1
T
2
T
3
T
0
T
1
T
2
T
3
S=1
a
MA7 MA5 MA3 MA1
M=1 MA6 MA4 MA2 MA0
MB7 MB4 MB1
MB6 MB3 MB0
MB5 MB2
R2
CTM/CFM
ROW2
DR4T DR2 BR0
BR3 RsvR
R8
R5
ROW1
DR4F DR1 BR1
BR4 RsvR
R7
R4
R1
ROW0
DR3
DR0 BR2 RsvB AV=1 R6
R3
R0
ACT a0
PREX d0
MSK (b1)
PRER c0
WR b1
C4
CTM/CFM
COL4
DC4
S=1
RsvC
COL3
DC3
C5
C3
COL2
DC2 COP1
RsvB BC2
C2
DC1 COP0
BC4
BC1
C1
DC0 COP2
COP3 BC3
BC0
C0
COL1
COL0
CTM/CFM
ROW2
ROW1
ROW0
CTM/CFM
COL4
COL3
COL2
COL1
COL0
ROP2
DR4T DR2 BR0
BR3
ROP10
ROP8 ROP5
DR4F DR1 BR1
BR4 ROP9 ROP7 ROP4 ROP1
DR3
DR0 BR2 RsvB AV=0 ROP6 ROP3 ROP0
S=1
b
DX4 XOP4 RsvB BX1
M=0 DX3 XOP3 BX4
BX0
DX2 XOP2 BX3
DX1 XOP1 BX2
DX0 XOP0
T
0
T
4
T
8
T
12
T
1
T
5
T
9
T
13
T
2
T
6
T
10
T
14
T
3
T
7
T
11
T
15
ROWA Packet
COLM Packet
COLC Packet
COLX Packet
ROWR Packet
CTM/CFM
DQA8..0
DQB8..0
COL4
..COL0
ROW2
..ROW0
t
PACKET
a
The COLM is associated with a
previous COLC, and is aligned
with the present COLC, indicated
by the Start bit (S=1) position.
b
The COLX is aligned
with the present COLC,
indicated by the Start
bit (S=1) position.
Direct RDRAM
TM
Page 8
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Field Encoding Summary
Table 5 shows how the six device address bits are decoded
for the ROWA and ROWR packets. The DR4T and DR4F
encoding merges a fifth device bit with a framing bit. When
neither bit is asserted, the device is not selected. Note that a
broadcast operation is indicated when both bits are set.
Broadcast operation would typically be used for refresh and
power management commands. If the device is selected, the
DM (DeviceMatch) signal is asserted and an ACT or ROP
command is performed.
Table 6 shows the encodings of the remaining fields of the
ROWA and ROWR packets. An ROWA packet is specified
by asserting the AV bit. This causes the specified row of the
specified bank of this device to be loaded into the associated
sense amps.
An ROWR packet is specified when AV is not asserted. An
11 bit opcode field encodes a command for one of the banks
of this device. The PRER command causes a bank and its
two associated sense amps to precharge, so another row or
an adjacent bank may be activated. The REFA (refresh-acti-
vate) command is similar to the ACT command, except the
row address comes from an internal register REFR, and
REFR is incremented at the largest bank address. The REFP
(refresh-precharge) command is identical to a PRER
command.
The NAPR, NAPRC, PDNR, ATTN, and RLXR commands
are used for managing the power dissipation of the RDRAM
and are described in more detail in
"
Power State Manage-
ment
"
on page 50. The TCEN and TCAL commands are
used to adjust the output driver slew rate and they are
described in more detail in
"
Current and Temperature
Control
"
on page 56.
Table 5: Device Field Encodings for ROWA Packet and ROWR Packet
DR4T
DR4F
Device Selection
Device Match signal (DM)
1
1
All devices (broadcast)
DM is set to 1
0
1
One device selected
DM is set to 1 if {DEVID4..DEVID0} == {0,DR3..DR0} else DM is set to 0
1
0
One device selected
DM is set to 1 if {DEVID4..DEVID0} == {1,DR3..DR0} else DM is set to 0
0
0
No packet present
DM is set to 0
Table 6: ROWA Packet and ROWR Packet Field Encodings
DM
a
AV
ROP10..ROP0 Field
Name
Command Description
10
9
8
7
6
5
4
3
2:0
0
-
-
-
-
-
-
-
-
-
---
-
No operation.
1
1
Row address
ACT
Activate row R8..R0 of bank BR4..BR0 of device and move device to ATTN
b
.
1
0
1
1
0
0
0
x
c
x
x
000
PRER
Precharge bank BR4..BR0 of this device.
1
0
0
0
0
1
1
0
0
x
000
REFA
Refresh (activate) row REFR8..REFR0 of bank BR4..BR0 of device.
Increment REFR if BR4..BR0 = 11111 (see Figure 51).
1
0
1
0
1
0
1
0
0
x
000
REFP
Precharge bank BR4..BR0 of this device after REFA (see Figure 51).
1
0
x
x
0
0
0
0
1
x
000
PDNR
Move this device into the powerdown (PDN) power state (see Figure 48).
1
0
x
x
0
0
0
1
0
x
000
NAPR
Move this device into the nap (NAP) power state (see Figure 48).
1
0
x
x
0
0
0
1
1
x
000
NAPRC
Move this device into the nap (NAP) power state conditionally
1
0
x
x
x
x
x
x
x
0
000
ATTN
b
Move this device into the attention (ATTN) power state (see Figure 46).
1
0
x
x
x
x
x
x
x
1
000
RLXR
Move this device into the standby (STBY) power state (see Figure 47).
1
0
0
0
0
0
0
0
0
x
001
TCAL
Temperature calibrate this device (see Figure 54).
1
0
0
0
0
0
0
0
0
x
010
TCEN
Temperature calibrate/enable this device (see Figure 54).
1
0
0
0
0
0
0
0
0
0
000
NOROP
No operation.
a. The DM (Device Match signal) value is determined by the DR4T,DR4F, DR3..DR0 field of the ROWA and ROWR packets. See Table 5.
b. The ATTN command does not cause a RLX-to-ATTN transition for a broadcast operation (DR4T/DR4F=1/1).
c. An
"
x
"
entry indicates which commands may be combined. For instance, the three commands PRER/NAPRC/RLXR may be specified in one ROP value (011000111000).
Direct RDRAM
TM
Page 9
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Table 7 shows the COP field encoding. The device must be
in the ATTN power state in order to receive COLC packets.
The COLC packet is used primarily to specify RD (read) and
WR (write) commands. Retire operations (moving data from
the write buffer to a sense amp) happen automatically. See
Figure 18 for a more detailed description.
The COLC packet can also specify a PREC command,
which precharges a bank and its associated sense amps. The
RDA/WRA commands are equivalent to combining RD/WR
with a PREC. RLXC (relax) performs a power mode transi-
tion. See
"
Power State Management
"
on page 50.
Table 8 shows the COLM and COLX field encodings. The
M bit is asserted to specify a COLM packet with two 8 bit
bytemask fields MA and MB. If the M bit is not asserted, an
COLX is specified. It has device and bank address fields,
and an opcode field. The primary use of the COLX packet is
to permit an independent PREX (precharge) command to be
specified without consuming control bandwidth on the ROW
pins. It is also used for the CAL(calibrate) and SAM
(sample) current control commands (see
"
Current and
Temperature Control
"
on page 56), and for the RLXX power
mode command (see
"
Power State Management
"
on page
50).
Table 7: COLC Packet Field Encodings
S
DC4.. DC0
(select device)
a
COP3..0 Name
Command Description
0
----
-----
-
No operation.
1
/= (DEVID4 ..0)
-----
-
Retire write buffer of this device.
1
== (DEVID4 ..0)
x000
b
NOCOP
Retire write buffer of this device.
1
== (DEVID4 ..0)
x001
WR
Retire write buffer of this device, then write column C5..C0 of bank BC4..BC0 to write buffer.
1
== (DEVID4 ..0)
x010
RSRV
Reserved, no operation.
1
== (DEVID4 ..0)
x011
RD
Read column C5..C0 of bank BC4..BC0 of this device.
1
== (DEVID4 ..0)
x100
PREC
Retire write buffer of this device, then precharge bank BC4..BC0 (see Figure 15).
1
== (DEVID4 ..0)
x101
WRA
Same as WR, but precharge bank BC4..BC0 after write buffer (with new data) is retired.
1
== (DEVID4 ..0)
x110
RSRV
Reserved, no operation.
1
== (DEVID4 ..0)
x111
RDA
Same as RD, but precharge bank BC4..BC0 afterward.
1
== (DEVID4 ..0)
1xxx
RLXC
Move this device into the standby (STBY) power state (see Figur e 47).
a.
"
/=
"
means not equal,
"
==
"
means equal.
b. An
"
x
"
entry indicates which commands may be combined. For instance, the two commands WR/RLXC may be specified in one COP value (1001).
Table 8: COLM Packet and COLX Packet Field Encodings
M
DX4 .. DX0
(selects device)
XOP4..0
Name
Command Description
1
----
-
MSK
MB/MA bytemasks used by WR/WRA.
0
/= (DEVID4 ..0)
-
-
No operation.
0
== (DEVID4 ..0)
00000
NOXOP
No operation.
0
== (DEVID4 ..0)
1xxx0
a
PREX
Precharge bank BX4..BX0 of this device (see Figure 15).
0
== (DEVID4 ..0)
x10x0
CAL
Calibrate (drive) I
OL
current for this device (see Figure 53).
0
== (DEVID4 ..0)
x11x0
CAL/SAM
Calibrate (drive) and Sample ( update) I
OL
current for this device (see Figure 53).
0
== (DEVID4 ..0)
xxx10
RLXX
Move this device into the standby (STBY) power state (see Figur e 47).
0
== (DEVID4 ..0)
xxxx1
RSRV
Reserved, no operation.
a. An
"
x
"
entry indicates which commands may be combined. For instance, the two commands PREX/RLXX may be specified in one XOP value ( 10010 ).
Direct RDRAM
TM
Page 10
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Electrical Conditions
Table 9: Electrical Conditions
Symbol
Parameter and Conditions
Min
Max
Unit
T
J
Junction temperature under bias
-
100
C
V
DD,
V
DDA
Supply voltage
2.50 - 0.13
2.50 + 0.13
V
V
DD,N,
V
DDA,N
Supply voltage droop (DC) during NAP interval (t
NLIMIT
)
-
2.0
%
v
DD,N,
v
DDA,N
Supply voltage ripple (AC) during NAP interval (t
NLIMIT
)
-2.0
2.0
%
V
CMOS
a
Supply voltage for CMOS pins (2.5V controllers)
Supply voltage for CMOS pins (1.8V controllers)
V
DD
1.80 - 0.1
V
DD
1.80 + 0.2
V
V
V
REF
Reference voltage
1.40 - 0.2
1.40 + 0.2
V
V
DIL
RSL data input - low voltage
V
REF
- 0.5
V
REF
- 0.2
V
V
DIH
RSL data input - high voltage
b
V
REF
+ 0.2
V
REF
+ 0.5
V
R
DA
RSL data asymmetry: R
DA
= (V
DIH
- V
REF
) / (V
REF
- V
DIL
)
0.67
1.00
-
V
CM
RSL clock input - common mode V
CM
= (V
CIH
+V
CIL)
/2
1.3
1.8
V
V
CIS,CTM
RSL clock input swing: V
CIS
= V
CIH
- V
CIL
(CTM,CTMN pins).
0.35
1.00
V
V
CIS,CFM
RSL clock input swing: V
CIS
= V
CIH
- V
CIL
(CFM,CFMN pins).
0.225
1.00
V
V
IL,CMOS
CMOS input low voltage
- 0.3
c
V
CMOS
/2 - 0.25
V
V
IH,CMOS
CMOS input high voltage
V
CMOS
/2 + 0.25
V
CMOS
+0.3
d
V
a. V
CMOS
must remain on as long as V
DD
is applied and cannot be turned off.
b. V
DIH
is typically equal to V
TERM
(1.8V
0.1V) under DC conditions in a system.
c. Voltage undershoot is limited to -0.7V for a duration of less than 5ns.
d. Voltage overshoot is limited toV
CMOS
+0.7V for a duration of less than 5ns
Direct RDRAM
TM
Page 11
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Electrical Characteristics
Table 10: Electrical Characteristics
Symbol
Parameter and Conditions
Min
Max
Unit
JC
Junction-to-Case thermal resistance
-
0.5
C/Watt
I
REF
V
REF
current @ V
REF,MAX
-10
10
A
I
OH
RSL output high current @ (0
V
OUT
V
DD
)
-10
10
A
I
ALL
RSL I
OL
current @ V
OL
= 0.9V, V
DD,MIN
, T
J,MAX
a
a. This measurement is made in manual current control mode; i.e. with all output device leg s sinking current.
30.0
90.0
mA
I
OL
RSL I
OL
current resolution step
-
2.0
mA
r
OUT
Dynamic output impedance @ V
OL
= 0.9V
150
-
I
OL
RSL I
OL
current @ V
OL
= 1.0V
b,c
b. This measurement is made in automatic current control mode after at least 64 current control calibration operations to a device and after CCA and
CCB are initialized to a value of 64. This value applies to all DQA and DQB pins.
c. This measurement is made in automatic current control mode in a 25
test system with V
TERM
= 1.714V and V
REF
= 1.357V and with the ASYMA
and ASYMB register fields set to 0.
26.6
30.6
mA
I
I,CMOS
CMOS input leakage current @ (0
V
I,CMOS
V
CMOS
)
-10.0
10.0
A
V
OL,CMOS
CMOS output voltage @ I
OL,CMOS
= 1.0mA
-
0.3
V
V
OH,CMOS
CMOS output high voltage @ I
OH,CMOS
= -0.25mA
V
CMOS
-0.3
-
V
Direct RDRAM
TM
Page 12
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Timing Conditions
Table 11: Timing Conditions
Symbol
Parameter
Min
Max
Unit
Figure(s)
t
CYCLE
CTM and CFM cycle times (-800)
2.50
3.83
ns
Figure 55
CTM and CFM cycle times (-711)
2.80
3.83
CTM and CFM cycle times (-600)
3.33
3.83
t
CR
, t
CF
CTM and CFM input rise and fall times. Use the minimum value
of these parameters during testing.
0.2
0.5
ns
Figure 55
t
CH
, t
CL
CTM and CFM high and low times
40%
60%
t
CYCLE
Figure 55
t
TR
CTM-CFM differential (MSE/MS=0/0)
CTM-CFM differential (MSE/MS=1/1)
a
0.0
0.9
1.0
1.0
t
CYCLE
Figure 43
Figure 55
t
DCW
Domain crossing window
-0.1
0.1
t
CYCLE
Figure 61
t
DR
, t
DF
DQA/DQB/ROW/COL input rise/fall times (20% to 80%). Use
the minimum value of these parameters during testing.
0.2
0.65
ns
Figure 56
t
S
, t
H
DQA/DQB/ROW/COL-to-CFM set/hold @ t
CYCLE
=2.50ns
DQA/DQB/ROW/COL-to-CFM set/hold @ t
CYCLE
=2.81ns
DQA/DQB/ROW/COL-to-CFM set/hold @ t
CYCLE
=3.33ns
0.200
b
0.240
b,c
0.275
b,d
-
-
-
ns
Figure 56
t
DR1,
t
DF1
SIO0, SIO1 input rise and fall times
-
5.0
ns
Figure 58
t
DR2,
t
DF2
CMD, SCK input rise and fall times
-
2.0
ns
Figure 58
t
CYCLE1
SCK cycle time - Serial control register transactions
1000
-
ns
Figure 58
SCK cycle time - Power transitions
10
-
ns
Figure 58
t
CH1
, t
CL1
SCK high and low times
4.25
-
ns
Figure 58
t
S1
CMD setup time to SCK rising or falling edge
e
1.25
-
ns
Figure 58
t
H1
CMD hold time to SCK rising or falling edge
e
1
-
ns
Figure 58
t
S2
SIO0 setup time to SCK falling edge
40
-
ns
Figure 58
t
H2
SIO0 hold time to SCK falling edge
40
-
ns
Figure 58
t
S3
PDEV setup time on DQA5..0 to SCK rising edge.
0
-
ns
Figure 49
t
H3
PDEV hold time on DQA5..0 to SCK rising edge.
5.5
-
ns
Figure 59
t
S4
ROW2..0, COL4..0 setup time for quiet window
-1
-
t
CYCLE
Figure 49
t
H4
ROW2..0, COL4..0 hold time for quiet window
f
5
-
t
CYCLE
Figure 49
t
NPQ
Quiet on ROW/COL bits during NAP/PDN entry
4
-
t
CYCLE
Figure 48
t
READTOCC
Offset between read data and CC packets (same device)
12
-
t
CYCLE
Figure 53
t
CCSAMTOREAD
Offset between CC packet and read data (same device)
8
-
t
CYCLE
Figure 53
t
CE
CTM/CFM stable before NAP/PDN exit
2
-
t
CYCLE
Figure 49
t
CD
CTM/CFM stable after NAP/PDN entry
100
-
t
CYCLE
Figure 48
t
FRM
ROW packet to COL packet ATTN framing delay
7
-
t
CYCLE
Figure 47
t
NLIMIT
Maximum time in NAP mode
10.0
s
Figure 46
Direct RDRAM
TM
Page 13
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
t
REF
Refresh interval
32
ms
Figure 51
t
BURST
Interval after PDN or NAP (with self-refresh) exit in which all
banks of the RDRAM must be refreshed at least once.
200
s
Figure 52
t
CCTRL
Current control interval
34 t
CYCLE
100ms
ms/t
CYCLE
Figure 53
t
TEMP
Temperature control interval
100
ms
Figure 54
t
TCEN
TCE command to TCAL command
150
-
t
CYCLE
Figure 54
t
TCAL
TCAL command to quiet window
2
2
t
CYCLE
Figure 54
t
TCQUIET
Quiet window (no read data)
140
-
t
CYCLE
Figure 54
t
PAUSE
RDRAM delay (no RSL operations allowed)
200.0
s
page 38
a. MSE/MS are fields of the SKIP register. For this combination (skip override) the tDCW parameter range is effectively 0.0 to 0.0.
b.
t
S,MIN
and t
H,MIN
for other t
CYCLE
values can be interpolated between or extrapolated from the timings at the 3 specified t
CYCLE
values.
c.
This parameter also applies to a -800 part when operated with t
CYCLE
=2.81ns.
d. This parameter also applies to a -800 or -711 part when operated with t
CYCLE
=3.33ns.
e. With V
IL,CMOS
=0.5V
CMOS
-0.4V and V
IH,CMOS
=0.5V
CMOS
+0.4V
f. Effective hold becomes t
H4
'=t
H4
+[PDNXA
64
t
SCYCLE
+t
PDNXB,MAX
]-[PDNX
256t
SCYCLE
]
if [PDNX
256
t
SCYCLE
] < [PDNXA
64
t
SCYCLE
+t
PDNXB,MAX
]. See Figure 49.
Table 11: Timing Conditions
Symbol
Parameter
Min
Max
Unit
Figure(s)
Direct RDRAM
TM
Page 14
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Timing Characteristics
Table 12: Timing Characteristics
Symbol
Parameter
Min
Max
Unit
Figure(s)
t
Q
CTM-to-DQA/DQB output time @ t
CYCLE
=2.50ns
-0.260
a
+0.260
a
ns
Figure 57
CTM-to-DQA/DQB output time @ t
CYCLE
=2.81ns
-0.300
a,b
+0.300
a,b
CTM-to-DQA/DQB output time @ t
CYCLE
=3.33ns
0.350
a,c
+0.350
a,c
t
QR
, t
QF
DQA/DQB output rise and fall times
0.2
0.45
ns
Figure 57
t
Q1
SCK(neg)-to-SIO0 delay @ C
LOAD,MAX
= 20pF (SD read data valid).
-
10
ns
Figure 60
t
HR
SCK(pos)-to-SIO0 delay @ C
LOAD,MAX
= 20pF (SD read data hold).
2
-
ns
Figure 60
t
QR1
, t
QF1
SIO
OUT
rise/fall @ C
LOAD,MAX
= 20pF
-
5
ns
Figure 60
t
PROP1
SIO0-to-SIO1 or SIO1-to-SIO0 delay @ C
LOAD,MAX
= 20pF
-
10
ns
Figure 60
t
NAPXA
NAP exit delay - phase A
-
50
ns
Figure 49
t
NAPXB
NAP exit delay - phase B
-
40
ns
Figure 49
t
PDNXA
PDN exit delay - phase A
-
4
s
Figure 49
t
PDNXB
PDN exit delay - phase B
-
9000
t
CYCLE
Figure 49
t
AS
ATTN-to-STBY power state delay
-
1
t
CYCLE
Figure 47
t
SA
STBY-to-ATTN power state delay
-
0
t
CYCLE
Figure 47
t
ASN
ATTN/STBY-to-NAP power state delay
-
8
t
CYCLE
Figure 48
t
ASP
ATTN/STBY-to-PDN power state delay
-
8
t
CYCLE
Figure 48
a. t
Q,MIN
and t
Q,MAX
for other t
CYCLE
values can be interpolated between or extrapolated from the timings at the 3 specified t
CYCLE
values.
b. This parameter also applies to a -800 part when operated with t
CYCLE
=2.81ns.
c. This parameter also applies to a -800 or -711 part when operated with t
CYCLE
=3.33ns.
Direct RDRAM
TM
Page 15
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Timing Parameters
Table 13: Timing Parameter Summary
Parameter
Description
Min
-45
-800
Min
-45
-711
Min
-53.3
-600
Max
Units
Figure(s)
t
RC
Row Cycle time of RDRAM banks -the interval between ROWA packets with
ACT commands to the same bank.
28
28
28
-
t
CYCLE
Figure 16
Figure 17
t
RAS
RAS-asserted time of RDRAM bank - the interval between ROWA packet
with ACT command and next ROWR packet with PRER
a
command to the
same bank.
20
20
20
64
s
b
t
CYCLE
Figure 16
Figure 17
t
RP
Row Precharge time of RDRAM banks - the interval between ROWR packet
with PRER
a
command and next ROWA packet with ACT command to the
same bank.
8
8
8
-
t
CYCLE
Figure 16
Figure 17
t
PP
Precharge-to-precharge time of RDRAM device - the interval between succes-
sive ROWR packets with PRER
a
commands to any banks of the same device.
8
8
8
-
t
CYCLE
Figure 13
t
RR
RAS-to-RAS time of RDRAM device - the interval between successive
ROWA packets with ACT commands to any banks of the same device.
8
8
8
-
t
CYCLE
Figure 14
t
RCD
RAS-to-CAS Delay - the interval from ROWA packet with ACT command to
COLC packet with RD or WR command). Note - the RAS-to-CAS delay seen
by the RDRAM core (t
RCD-C
) is equal to t
RCD-C
= 1 + t
RCD
because of differ-
ences in the row and column paths through the RDRAM interface.
9
7
7
-
t
CYCLE
Figure 16
Figure 17
t
CAC
CAS Access delay - the interval from RD command to Q read data. The equa-
tion for t
CAC
is given in the TPARM register in Figure 40.
8
8
8
12
t
CYCLE
Figure 5
Figure 40
t
CWD
CAS Write Delay (interval from WR command to D write data.
6
6
6
6
t
CYCLE
Figure 5
t
CC
CAS-to-CAS time of RDRAM bank - the interval between successive COLC
commands).
4
4
4
-
t
CYCLE
Figure 16
Figure 17
t
PACKET
Length of ROWA, ROWR, COLC, COLM or COLX packet.
4
4
4
4
t
CYCLE
Figure 3
t
RTR
Interval from COLC packet with WR command to COLC packet which causes
retire, and to COLM packet with bytemask.
8
8
8
-
t
CYCLE
Figure 18
t
OFFP
The interval (offset) from COLC packet with RDA command, or from COLC
packet with retire command (after WRA automatic precharge), or from COLC
packet with PREC command, or from COLX packet with PREX command to
the equivalent ROWR packet with PRER. The equation for t
OFFP
is given in
the TPARM register in Figure 40.
4
4
4
4
t
CYCLE
Figure 15
Figure 40
t
RDP
Interval from last COLC packet with RD command to ROWR packet with
PRER.
4
4
4
-
t
CYCLE
Figure 16
t
RTP
Interval from last COLC packet with automatic retire command to ROWR
packet with PRER.
4
4
4
-
t
CYCLE
Figure 17
a. Or equivalent PREC or PREX command. See Figur e 15.
b. This is a constraint imposed by the core, and is therefore in units of
s rather than t
CYCLE
.
Direct RDRAM
TM
Page 16
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Absolute Maximum Ratings
I
DD
- Supply Current Profile
a.The supply current will be 150mA when t
CYCLE
is in the range 15ns to 1000ns.
Table 14: Absolute Maximum Ratings
Symbol
Parameter
Min
Max
Unit
V
I,ABS
Voltage applied to any RSL or CMOS pin with respect to Gnd
- 0.3
V
DD
+0.3
V
V
DD,ABS
, V
DDA,ABS
Voltage on VDD and VDDA with respect to Gnd
- 0.5
V
DD
+1.0
V
T
STORE
Storage temperature
- 50
100
C
Table 15: Supply Current Profile
I
DD
value
RDRAM Power State and Steady-State Transaction Rates
a
a. CMOS interface consumes power in all power states.
b. x16/x18 RDRAM data width.
c. This does not include the I
OL
sink current. The RDRAM dissipates I
OL
V
OL
in each output driver when a logic one is driven.
Min
Max
-45
-800
Max
-45
-711
Max
-53.3
-600
Unit
I
DD,PDN
Device in PDN, self-refresh enabled and INIT.LSR=0.
-
5000
5000
5000
A
I
DD,NAP
Device in NAP.
-
4
4
4
mA
I
DD,STBY
Device in STBY. This is the average for a device in STBY with (1) no
packets on the Channel, and (2) with packets sent to other devices.
-
105
100
90
mA
I
DD,REFRESH
Device in STBY and refreshing rows at the t
REF,MAX
period.
-
105
100
90
mA
I
DD,ATTN
Device in ATTN. This is the average for a device in ATTN with (1) no
packets on the Channel, and (2) with packets sent to other devices.
-
165
155
140
mA
I
DD,ATTN-W
Device in ATTN. ACT command every 8t
CYCLE
, PRE command
every 8t
CYCLE
, WR command every 4
t
CYCLE
, and data is 1100..1100
-
575/
625
b
525/
580
455/
500
mA
I
DD,ATTN-R
Device in ATTN. ACT command every 8t
CYCLE
, PRE command
every 8
t
CYCLE
, RD command every 4
t
CYCLE
, and data is
1111..1111
c
-
490/
520
450/
480
400/
420
mA
Table 16: Supply Current at Initialization
Symbol
Parameter
Allowed Range of t
CYCLE
V
DD
Min
Max
Unit
I
DD,PWRUP,D
I
DD
from power -on to SETR
3.33ns to 3.83ns
2.50ns to 3.32ns
V
DD,MIN
-
150
a
200
mA
I
DD,SETR,D
I
DD
from SETR to CLRR
3.33ns to 3.83ns
2.50ns to 3.32ns
V
DD,MIN
-
250
332
mA
Direct RDRAM
TM
Page 17
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Capacitance and Inductance
Table 17: RSL Pin Parasitics
Symbol
Parameter and Conditions - RSL pins
Min
Max
Unit
Figure
L
I
RSL effective input inductance
4.0
nH
Figure 62
L
12
Mutual inductance between any DQA or DQB RSL signals.
0.2
nH
Figure 62
Mutual inductance between any ROW or COL RSL signals.
0.6
nH
L
I
Difference in L
I
value between any RSL pins of a single device.
-
1.8
nH
Figure 62
C
I
RSL effective input capacitance
a
800
2.0
2.4
pF
Figure 62
711
2.0
2.4
600
2.0
2.6
C
12
Mutual capacitance between any RSL signals.
-
0.1
pF
Figure 62
C
I
Difference in C
I
value between average of {CTM, CTMN, CFM,
CFMN} and any RSL pins of a single device.
-
0.06
pF
Figure 62
R
I
RSL effective input resistance
4
15
Figure 62
a. This value is a combination of the device IO circuitry and package capacitances measured at VDD=2.5V and f=400MHz with pin biased at 1.4V.
Table 18: CMOS Pin Parasitics
Symbol
Parameter and Conditions - CMOS pins
Min
Max
Unit
Figure
L
I ,CMOS
CMOS effective input inductance
8.0
nH
Figure 62
C
I ,CMOS
CMOS effective input capacitance (SCK,CMD)
a
1.7
2.1
pF
C
I ,CMOS,SIO
CMOS effective input capacitance (SIO1, SIO0)
a
-
7.0
pF
a. This value is a combination of the device IO circuitry and package capacitances.
Direct RDRAM
TM
Page 18
K4R271669A/K4R441869A
Version 1.11 Oct. 2000
Center-Bonded uBGA Package
(62 Balls)
Figure 4 shows the form and dimensions of the recom-
mended package for the center-bonded CSP device class
Figure 4: Center-Bonded uBGA Package
Table 19 lists the numerical values corresponding to dimen-
sions shown in Figure 4.
Table 19: Center-Bonded uBGA Package Dimensions
A
B
C
D
E
F
G
H
J
1
2
3
4
5
6
7
D
A
e1
d
E
E1
8
e2
Top
Bottom
Bottom
Bottom
9
10
11
12
Symbol
Parameter
Min
(128Mb/144Mb)
Max
(128Mb/144Mb)
Unit
e1
Ball pitch (x-axis)
1.00
1.00
mm
e2
Ball pitch (y-axis)
0.8
0.8
mm
A
Package body length
11.90
12.10
mm
D
Package body width
10.10
10.30
mm
E
Package total thickness
-
1.00
a
mm
E1
Ball height
0.20
0.30
mm
d
Ball diameter
0.30
0.40
mm
a. The E,MAX parameter for SO-RIMM applications is 0.94mm.