ChipFind - документация

Электронный компонент: GP1U783R

Скачать:  PDF   ZIP
GP1U78R Series
s
Outline Dimensions
(Unit : mm )
s
Features
s
Absolute Maximum Ratings
(Ta = 25C )
s
Applications
s
Recommended Operations Conditions
s
Electrical Characteristics
1. Less sensitive to fluorescent lamp driven
by inverter.
2. Improved anti-electromagnetic noise char-
acteristic by mesh type light detecting
window.
*3 The burst wave as shown in the following figure shall be transmitted by the transmitter shown in Fig. 1.
Parameter
Symbol
MIN.
TYP.
Dissipation current
I
CC
-
-
High level output voltage
V
OH
V
CC
- 0.5
-
Low level output voltage
V
OL
-
-
High level pulse width
T
1
400
-
Low level pulse width
T
2
400
-
B. P. F. center frequency
f
o
-
*1 No dew formation
*2 For 5 seconds
GP1U78R Series
2
2
15.6
1.6
3.6
1.7
2.54
2.54
3.3
14.2
1.4
3.9
2.4
Rib
Recommended drilling as viewed
from the soldering face
1 2 3
1 Vout
2 Vcc
3 GND
1 2 3
Parameter
Symbol
Value
Unit
Supply voltage
V
CC
4.7 to 5.3
V
Parameter
Symbol
Rating
Unit
Supply voltage
V
CC
0 to 6.3
V
*1
Operating temperature
T
opr
- 10 to + 70
C
Storage temperature
S
stg
- 20 to + 70
C
*2
Soldering temperature
T
sol
260
C
Conditions
No input light
*3
-
( Ta = 25C, V
CC
= + 5V)
MAX.
Unit
5.0
mA
-
V
0.45
V
800
s
800
-
kHz
g
1 Detector center
g
1
g
1
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
"
"
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
Remote Control
IR Detecting Unit For
3. Various B.P.F ( Band Pass Filter ) frequency
*4
40
*4 Diversified models with a different B. P. F. frequency, as shown in a separate table, are also available.
* Tolerance
:
0.3mm
3
-
0.8
7.5
0.5
3.65
0.5
12.6
+
0.5
-
0.3
15
+
0.5
-
0.3
1. TVs
2. VCRs
4. BS receivers
3. CATV set top boxes
GP1U78R Series
s
Model Line-up
s
Internal Block Diagram
The value of f
O
is shown in a separate table.
Duty 50%
600
s
600
s
Model No.
B.P.F. frequency
Unit
GP1U78R
40
kHz
GP1U780R
36
GP1U781R
38
GP1U782R
36.7
GP1U783R
32.75
GP1U787R
56.8
Vout
Vcc
GND
B.P.F.
Limiter
Amp
Comparator
Integrator
Demodulator
GP1U78R Series
s
Performance
( 1) Linear reception distance characteristics
( 2) Sensitivity angle reception distance characteristics
( 3) Anti outer peripheral light reception distance characteristics
In the above figure, the transmitter should be set so that the output V out can be 40mV
PP
.
100 lx.
(E
V
is an illuminance by CIE standard light source A ( tungsten lamp ) .)
20cm
10k
+
5V
10
F
PD49PI
10k
Oscilloscope
Vout
Transmitter
Vout
Transmitter (GL521 used )
Duty 50
%
Center frequency (fo)
depends on the attached
model list.
Fig. 1. Transmitter
Fig. 2. Standard optical system
Reception distance
:
L
Light detector face
illuminance
:
Ee
vertical directions. )
Using the transmitter shown in Fig. 1, the output signal of the light detecting unit is good enough
to meet the following items in the standard optical system in Fig. 2.
However, the
PD49PI
to be used here should be of the short-circuit current I
SC
= 2.6
A at E
V
=

(
indicates horizontal and
When L= 0.2 to 6.5m, Ee< 10 lx and
= 0 in Fig. 2, the output signal shall meet the electrical
characteristcs in the attached list.
When L= 0.2 to 4.5m, Ee< 10 lx and
<=30 in Fig. 2, the output signal shall meet the electrical
characteristics in the attached list.
When L= 0.2 to 3m, Ee<= 300 lx and
= 0 in Fig. 2, the output signal shall meet the electrical
characteristics in the attached list.
s
Precautions for Use
GP1U78R Series
( 2) Pay attention to a malfunction of the light detecting unit when the surface is stained with
( 3) The shield case shall be grounded on PWB pattern.
( 4) Do not apply unnecessary force to the terminals and case form outside.
( 5) Do not push the light detector surface ( photodiode ) from outside.
( 6) To avoid the electorstatic breakdown of IC, handle the unit under the condition of ground-
( 7) In case of adopting the infrared light detecting unit for the wireless remote control, use it
( 8) As for other general cautions, refer to the chapter " Precautions for Use" ( Page 78 to 93 ) .
characteristics and operating condition of light emitting device and the characteristics of
the light detecting unit.
dust and refuse. Care must be taken not to touch the light detector surface. If it should be
dirty, wipe off with soft cloth so as to prevent scratch. In case some solvents are required,
use metyl alcohol, ethyl alcohol or isoprophyl alcohol. Also, protect the light detecting unit
against flux and others.
ing with human body, soldering iron, etc.
in accordance with the transmission scheme and the signal format recommended in" Coun-
termeasures for malfunction prevention of home appliances with infrared remote control"
issued form Japan Association of Electrical Home Appliances ( AEHA ) in July 1987.
( 1) Use the light emitting unit ( remote control transmitter ) , in consideration of performance,