Outline Dimensions
unit : mm
75
180
268
118
133
211.17 x 158.37
215.2 x 162.4
223 (Bezel Opening Area)
Effective Viewing Area
Active Area
7
60
(S)
(DL3)
(Bezel Opening Area)
122.9
15
1
A'
A
P0.33
7
0.3
P0.33
0.3
(135)
36.5
134
169
190
(132)
7MAX
B'
B
250
8.5
Large Size Graphic Type LCD Module
LM64P89L
(FA/POS/Measuring instruments)
Features
s
26 cm [10.4"] VGA format
s
Built-in long life CCFT B/L
s
Transmissive B/W display
s
High contrast (18 : 1)
Specifications
Parameter
Unit
Parameter
Unit
Display size
26 [10.4]
cm [ "]
Brightness
75
cd/m
2
Dot format (H x V)
640 x 480
dot
Duty ratio
1/240
-
Dot pitch (H x V)
0.33 x 0.33
mm
Backlight type
1CCFT(E)
-
Active area (H x V)
211.2 x 158.4
mm
Power consumption
2 550
mW
Panel type
*1
-
Outline dimensions (W x H x D) 250.0(268.0)*
2
x 190.0 x 7.0
mm
Panel mode
Transmissive
-
Weight
340
g
Color
B/W
-
Operating temperature
0 to +45
C
Contrast ratio
18 : 1
-
Storage temperature
-25 to +60
C
Response time
- [350]
ms
*1...Triple Super Twisted Nematic