S2V60
600V 1.7A
Copyright & Copy;2000 Shindengen Electric Mfg.Co.Ltd
OUTLINE DIMENSIONS
RATINGS
SHINDENGEN
Unit : mm
High voltage
High reliability with superior moisture
resistance
Applicable to Automatic Insertion
FEATURES
Conventional Rectification
Power source(Power Supply)
Home Appliances, Office Equipment
Telecommunication, Factory Automation
APPLICATION
Case : AX10
General Purpose Rectifiers
Single
Absolute Maximum Ratings (If not specified Tl=25)
Item
Symbol
Conditions
Ratings
Unit
Storage Temperature
Tstg
-55150
Operating Junction Temperature
Tj
150
Maximum Reverse Voltage
V
RM
600
V
Average Rectified Forward Current
I
O
50Hz sine wave, R-load, Ta=40
1.7
A
Peak Surge Forward Current
I
FSM
50Hz sine wave, Non-repetitive 1cycle peak value, Tj=25
60
A
Current Squared Time
I
2
t
1mst10msTj=25
20
A
2
s
Electrical Characteristics (If not specified Tl=25)
Item
Symbol
Conditions
Ratings
Unit
Forward Voltage
V
F
I
F
=1.7A, Pulse measurement
Max.1.05
V
Reverse Current
I
R
V
R
=V
RM
,
Pulse measurement
Max.10
A
Thermal Resistance
jl
junction to lead
Max.8
/W
0
0.5
1
1.5
2
2.5
0
0.5
1
1.5
2
2.5
S2Vx
Forward Power Dissipation
Tj = 150
C
Sine wave
Average Rectified Forward Current I
O
[A]
Forward Power Dissipation P
F
[W]
Peak Surge Forward Capability
0
10
20
30
40
50
60
70
1
10
100
S2Vx
2
5
20
50
I
FSM
10ms 10ms
1 cycle
Number of Cycles [cycles]
Peak Surge Forward Current I
FSM
[A]
non-repetitive,
sine wave,
Tj=25
C before
surge current is applied