ChipFind - документация

Электронный компонент: Q62702-D1026

Скачать:  PDF   ZIP
Silicon Schottky Diodes
BAT 14- ... 4
q
Medium barrier diodes for detector and mixer
applications
q
Hermetical ceramic package
q
For frequencies up to 40 GHz
ESD: Electrostatic discharge sensitive device, observe handling precautions!
Maximum Ratings
Type
Ordering Code
Package
1)
Pin Configuration
BAT 14-014
BAT 14-034
Q62702-D1005
Q62702-D1019
T1
Frequency
band (GHz)
... 4 (S)
BAT 14-044
BAT 14-064
Q62702-D1026
Q62702-D1036
... 8 (C)
BAT 14-074
BAT 14-094
Q62702-D1041
Q62702-D1051
... 12 (X)
BAT 14-104
BAT 14-114
Q62702-D1056
Q62702-D1061
... 18 (Ku)
BAT 14-124
Q62702-D1066
... 40 (Ka)
Cathode: black dot,
heat sink
Parameter
Symbol
Values
Unit
Reverse voltage
V
R
3
V
Junction temperature
T
j
175
C
Storage temperature range
T
stg
65 ... + 150
Forward current BAT 14-014 ... BAT 14-064
BAT 14-074 ... BAT 74-124
I
F
100
50
mA
Operating temperature range
T
op
65 ... + 150
1)
For detailed information see chapter Package Outlines.
BAT 14- ... 4
BAT 14- ... 4
Electrical Characteristics
at
T
A
= 25 C, unless otherwise specified.
Unit
Values
Parameter
Symbol
min.
typ.
max.
V
Breakdown voltage
I
R
= 10
A
V
(BR)
3
Forward voltage
I
F
= 1 mA
BAT 14-014/-034
BAT 14-044/-064
BAT 14-074/-094
BAT 14-104/-114
BAT 14-124
I
F
= 10 mA
BAT 14-014/-034
BAT 14-044/-064
BAT 14-074/-094
BAT 14-104/-114
BAT 14-124
V
F









0.42
0.43
0.44
0.46
0.47
0.5
0.53
0.55
0.58
0.63









pF
Diode capacitance
f
= 1 M Hz,
V
R
= 0
BAT 14-014/-034
BAT 14-044/-064
BAT 14-074/-094
BAT 14-104/-114
BAT 14-124
C
T




0.25
0.2
0.17
0.13
0.1
0.35
0.25
0.2
0.15
0.12
dB
Noise figure (single sideband)
IF amplifier noise
F
IF
= 1.5 dB,
P
LO
= 3 dBm,
f
IF
= 10.7 MHZ
f
= 3 GHz
BAT 14-014
BAT 14-034
f
= 6 GHz
BAT 14-044
BAT 14-064
f
= 9.3 GHz
BAT 14-074
BAT 14-094
f
= 16 GHz
BAT 14-104
BAT 14-114
BAT 14-124
F
SSB








5.5
6.5
5.5
6.5
5.5
6.5
6.0
7.0
9.0








Differential forward resistance
I
F
= 10/50 mA
BAT 14-014
BAT 14-034
BAT 14-044
BAT 14-064
BAT 14-074
BAT 14-094
BAT 14-104
BAT 14-114
BAT 14-124
r
f








3
4
3.5
4.5
4.5
5.5
5.5
7
8








Case capacitance
C
C
0.1
BAT 14- ... 4
BAT 14- ... 4
Forward current
I
F
=
f
(
V
F
)
of BAT 14-094
Measuring circuit for IF amplifier noise
Ceramic p. c. board for noise measurement
at 9.375 GHz (material = alumina;
E
R
= 9.94; thickness
= 0.635 mm)
Dimensions in mm
Single sideband noise
F
SSB
=
f
(
P
LO
)
f
LO
= 9.375 GHz,
f
IF
= 10.7 MHZ at
F
IF
= 1.5 dB