ChipFind - документация

Электронный компонент: ICX419AKL

Скачать:  PDF   ZIP
1
E01505
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
ICX419AKL
20 pin DIP (Cer-DIP)
Diagonal 8mm (Type 1/2) CCD Image Sensor for PAL Color Video Cameras
Description
The ICX419AKL is an interline CCD solid-state
image sensor suitable for PAL color video cameras
with a diagonal 8mm (Type 1/2) system. Compared
with the current product ICX039DNA, basic
characteristics such as sensitivity, smear, dynamic
range and S/N are improved drastically.
This chip features a field period readout system and
an electronic shutter with variable charge-storage
time. This chip is compatible with the pins of the
ICX039DNA and has the same drive conditions.
Features
High sensitivity (+6.0dB compared with the ICX039DNA)
Low smear (5.0dB compared with the ICX039DNA)
High D range (+3.0dB compared with the ICX039DNA)
High S/N
High resolution and low dark current
Excellent antiblooming characteristics
Ye, Cy, Mg, and G complementary color mosaic filters on chip
Continuous variable-speed shutter
Substrate bias:
Adjustment free (external adjustment also possible with 6 to 14V)
Reset gate pulse:
5Vp-p adjustment free (drive also possible with 0 to 9V)
Horizontal register: 5V drive
Device Structure
Interline CCD image sensor
Optical size:
Diagonal 8mm (Type 1/2)
Number of effective pixels: 752 (H)
582 (V) approx. 440K pixels
Total number of pixels:
795 (H)
596 (V) approx. 470K pixels
Chip size:
7.40mm (H)
5.95mm (V)
Unit cell size:
8.6m (H)
8.3m (V)
Optical black:
Horizontal (H) direction: Front 3 pixels, rear 40 pixels
Vertical (V) direction:
Front 12 pixels, rear 2 pixels
Number of dummy bits:
Horizontal 22
Vertical 1 (even fields only)
Substrate material:
Silicon
Optical black position
(Top View)
2
12
V
H
Pin 1
Pin 11
40
3
2
ICX419AKL
Block Diagram and Pin Configuration
(Top View)
11
12
13
14
15
16
17
18
19
20
Note) : Photo sensor
NC
V
DSUB
NC
GND
GND
RD
RG
NC
H
1
H
2
10
9
8
7
6
5
4
3
2
1
V
OUT
V
DD
GND
V
L
V
1
GND
SUB
V
2
V
3
V
4
Note)
Horizontal Register
V
e
r
tical Register
Cy
Cy
Mg
G
Cy
Mg
Cy
Cy
Mg
G
Cy
Mg
Ye
Ye
G
Mg
Ye
G
Ye
Ye
G
Mg
Ye
G
Pin Description
Pin No.
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Symbol
Description
V
4
V
3
V
2
SUB
GND
V
1
V
L
GND
V
DD
V
OUT
Vertical register transfer clock
Vertical register transfer clock
Vertical register transfer clock
Substrate clock
GND
Vertical register transfer clock
Protective transistor bias
GND
Output circuit supply voltage
Signal output
Symbol
Description
NC
V
DSUB
NC
GND
GND
RD
RG
NC
H
1
H
2
Substrate bias circuit supply voltage
GND
GND
Reset drain bias
Reset gate clock
Horizontal register transfer clock
Horizontal register transfer clock
3
ICX419AKL
Absolute Maximum Ratings
Item
Substrate clock
SUB
GND
Supply voltage
Clock input voltage
Voltage difference between vertical clock input pins
Voltage difference between horizontal clock input pins
H
1
, H
2
V
4
RG
GND
RG
SUB
V
L
SUB
Pins other than GND and
SUB
V
L
Storage temperature
Operating temperature
0.3 to +50
0.3 to +18
55 to +10
15 to +20
to +10
to +15
to +17
17 to +17
10 to +15
55 to +10
65 to +0.3
0.3 to +30
30 to +80
10 to +60
V
V
V
V
V
V
V
V
V
V
V
V
C
C
1
Ratings
Unit
Remarks
1
+27V (Max.) when clock width < 10s, clock duty factor < 0.1%.
V
DD
, V
RD
, V
DSUB
, V
OUT
GND
V
DD
, V
RD
, V
DSUB
, V
OUT
SUB
V
1
, V
2
, V
3
, V
4
GND
V
1
, V
2
, V
3
, V
4
SUB
4
ICX419AKL
DC Characteristics
Output circuit supply current
Item
I
DD
Symbol
5.0
Min.
Unit
Remarks
Typ.
Max.
mA
10.0
Bias Conditions 1 [when used in substrate bias internal generation mode]
Output circuit supply voltage
Reset drain voltage
Protective transistor bias
Substrate bias circuit supply voltage
Substrate clock
1
V
L
setting is the V
VL
voltage of the vertical transfer clock waveform, or the same supply voltage as the V
L
power supply for the V driver should be used. (When CXD1267AN is used.)
2
Do not apply a DC bias to the substrate clock pin, because a DC bias is generated within the CCD.
Item
V
DD
V
RD
V
L
V
DSUB
SUB
Symbol
15.0
15.0
1
15.0
2
Min.
V
V
V
Unit
Remarks
Typ.
Max.
14.55
14.55
14.55
15.45
15.45
15.45
V
RD
= V
DD
Bias Conditions 2 [when used in substrate bias external adjustment mode]
Output circuit supply voltage
Reset drain voltage
Protective transistor bias
Substrate bias circuit supply voltage
Substrate voltage adjustment range
Substrate voltage adjustment precision
3
V
L
setting is the V
VL
voltage of the vertical transfer clock waveform, or the same supply voltage as the V
L
power supply for the V driver should be used. (When CXD1267AN is used.)
4
Connect to GND or leave open.
5
The setting value of the substrate voltage (V
SUB
) is indicated on the back of the image sensor by a
special code. When adjusting the substrate voltage externally, adjust the substrate voltage to the indicated
voltage. The adjustment precision is 3%. However, this setting value has not significance when used in
substrate bias internal generation mode.
V
SUB
code -- one character indication
Code and optimal setting correspond to each other as follows.
Item
V
DD
V
RD
V
L
V
DSUB
V
SUB
V
SUB
Symbol
15.0
15.0
3
4
Min.
V
V
V
%
Unit
Remarks
Typ.
Max.
14.55
14.55
6.0
3
15.45
15.45
14.0
+3
V
RD
= V
DD
5
5
<Example> "L"
V
SUB
= 9.0V
V
SUB
code
Optimal setting
f
6.5
G
7.0
h
7.5
J
8.0
K
8.5
L
9.0
m
9.5
N
10.0
P
10.5
Q
11.0
S
12.0
U
13.0
V
13.5
W
14.0
R
11.5
T
12.5
E
6.0
5
ICX419AKL
Clock Voltage Conditions
1
Input the reset gate clock without applying a DC bias. In addition, the reset gate clock can also be driven
with the following specifications.
Readout clock voltage
Vertical transfer clock
voltage
Horizontal transfer
clock voltage
Reset gate clock
voltage
1
Substrate clock voltage
Item
V
VT
V
VH1
, V
VH2
V
VH3
, V
VH4
V
VL1
, V
VL2
,
V
VL3
, V
VL4
V
V
| V
VH1
V
VH2
|
V
VH3
V
VH
V
VH4
V
VH
V
VHH
V
VHL
V
VLH
V
VLL
V
H
V
HL
V
RGL
V
RG
V
RGLH
V
RGLL
V
SUB
Symbol
14.55
0.05
0.2
9.6
8.3
0.25
0.25
4.75
0.05
4.5
23.0
Min.
1
2
2
2
2
2
2
2
2
2
2
2
3
3
4
4
4
5
Waveform
diagram
V
VH
= (V
VH1
+ V
VH2
)/2
V
VL
= (V
VL3
+ V
VL4
)/2
V
V
= V
VH
n V
VL
n (n = 1 to 4)
High-level coupling
High-level coupling
Low-level coupling
Low-level coupling
Low-level coupling
Remarks
Reset gate clock
voltage
Item
V
RGL
V
RG
Symbol
4
4
Waveform
diagram
Remarks
15.0
0
0
9.0
9.0
5.0
0
1
5.0
24.0
Typ.
15.45
0.05
0.05
8.5
9.65
0.1
0.1
0.1
0.5
0.5
0.5
0.5
5.25
0.05
5.5
0.8
25.0
Max. Unit
V
V
V
V
Vp-p
V
V
V
V
V
V
V
Vp-p
V
V
Vp-p
V
Vp-p
0.2
8.5
Min.
0
9.0
Typ.
0.2
9.5
Max. Unit
V
Vp-p
6
ICX419AKL
Horizontal transfer clock equivalent circuit
Vertical transfer clock equivalent circuit
H
1
H
2
C
H1
C
H2
C
HH
V
1
C
V12
V
2
V
4
V
3
C
V34
C
V23
C
V41
C
V1
C
V2
C
V4
C
V3
R
GND
R
4
R
1
R
3
R
2
Clock Equivalent Circuit Constant
C
V1
, C
V3
C
V2
, C
V4
C
V12
, C
V34
C
V23
, C
V41
C
H1
C
H2
C
HH
C
RG
C
SUB
R
1
, R
3
R
2
, R
4
R
GND
Symbol
Capacitance between vertical transfer clock
and GND
Capacitance between vertical transfer clocks
Capacitance between horizontal transfer clock
and GND
Capacitance between horizontal transfer clocks
Capacitance between reset gate clock and GND
Capacitance between substrate clock and GND
Vertical transfer clock series resistor
Vertical transfer clock ground resistor
Item
Min.
3300
3300
820
330
120
91
47
11
680
75
82
68
Typ.
Max.
pF
pF
pF
pF
pF
pF
pF
pF
pF


Unit
Remarks
7
ICX419AKL
Drive Clock Waveform Conditions
(1) Readout clock waveform
(2) Vertical transfer clock waveform
V
VH
= (V
VH1
+ V
VH2
)/2
V
VL
= (V
VL3
+ V
VL4
)/2
V
V
= V
VH
n V
VL
n (n = 1 to 4)
100%
90%
10%
0%
tr
tf
0V
twh
M
2
M
V
VT
V
VH1
V
VHH
V
VHL
V
VH
V
VLH
V
VL1
V
VLL
V
VHL
V
VHH
V
VL
V
VHH
V
VH
V
VLH
V
VLL
V
VL
V
VHL
V
VL3
V
VHL
V
VH3
V
VHH
V
VH2
V
VHH
V
VHH
V
VHL
V
VHL
V
VH
V
VLH
V
VL2
V
VLL
V
VL
V
VH
V
VL
V
VHL
V
VLH
V
VLL
V
VHL
V
VH4
V
VHH
V
VHH
V
VL4
V
1
V
3
V
2
V
4
8
ICX419AKL
(3) Horizontal transfer clock waveform
(4) Reset gate clock waveform
V
RGLH
is the maximum value and V
RGLL
is the minimum value of the coupling waveform during the period from
Point A in the above diagram until the rising edge of RG. In addition, V
RGL
is the average value of V
RGLH
and
V
RGLL
.
V
RGL
= (V
RGLH
+ V
RGLL
)/2
Assuming V
RGH
is the minimum value during the period twh, then:
V
RG
= V
RGH
V
RGL
Negative overshoot level during the falling edge of RG is V
RGLm
.
(5) Substrate clock waveform
100%
90%
10%
0%
V
SUB
tr
tf
twh
M
2
M
V
SUB
tr
twh
tf
90%
10%
twl
V
H
V
HL
Point A
twl
V
RG
V
RGH
V
RGL
V
RGLH
RG waveform
V
RGLL
H
1
waveform
twh
tr
tf
+2.5V
V
RGLm
V
RGL
+ 0.5V
9
ICX419AKL
Clock Switching Characteristics
1
When vertical transfer clock driver CXD1267AN is used.
2
tf
tr 2ns.
3
The overlap period for twh and twl of horizontal transfer clocks H
1
and H
2
is two.
Min.
two
Typ.
Max.
16
20
Unit
ns
Remarks
Item
Horizontal transfer clock
Symbol
H
1
, H
2
3
Min.
twh
Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max.
twl
tr
tf
2.3
11
1.5
2.5
20
5.38
13
1.8
20
5.38
51
15
0.01
0.01
3
19
0.5
0.5
15
15
0.01
0.01
3
250
19
0.5
Unit
s
ns
ns
s
ns
s
Remarks
During readout
1
2
During drain
charge
Item
Readout clock
Vertical transfer
clock
Reset gate clock
Substrate clock
Symbol
V
T
V
1
, V
2
,
V
3
, V
4
H
H
1
H
2
RG
SUB
Hor
iz
ontal
tr
ansf
er cloc
k
0.5
During
imaging
During
parallel-serial
conversion
10
ICX419AKL
Image Sensor Characteristics
Item
Sensitivity
Saturation signal
Smear
Video signal shading
Uniformity between
video signal channels
Dark signal
Dark signal shading
Flicker Y
Flicker R-Y
Flicker B-Y
Line crawl R
Line crawl G
Line crawl B
Line crawl W
Lag
Symbol
S
Ysat
Sm
SHy
Sr
Sb
Ydt
Ydt
Fy
Fcr
Fcb
Lcr
Lcg
Lcb
Lcw
Lag
Min.
1040
1000
Typ.
1300
115
Max.
105
20
25
10
10
2
1
2
5
5
3
3
3
3
0.5
Unit
mV
mV
dB
%
%
%
%
mV
mV
%
%
%
%
%
%
%
%
Measurement
method
1
2
3
4
4
5
5
6
7
8
8
8
9
9
9
9
10
Remarks
Ta = 60C
Zone 0 and
I
Zone 0 to
II'
Ta = 60C
Ta = 60C
Zone Definition of Video Signal Shading
Measurement System
Note) Adjust the amplifier gain so that the gain between [
A] and [
Y], and between [
A] and [
C] equals 1.
CCD
C.D.S
LPF1
AMP
CCD signal output
Y signal output
Chroma signal output
(3dB down 6.3MHz)
(3dB down 1MHz)
[
C]
S/H
S/H
LPF2
[
Y]
[
A]
(Ta = 25C)
14
V
10
14
12
10
Ignored region
Effective pixel region
Zone 0,
I
Zone
II, II'
V
10
H
8
H
8
752 (H)
582 (V)
11
ICX419AKL
Image Sensor Characteristics Measurement Method
Measurement conditions
1) In the following measurements, the device drive conditions are at the typical values of the bias and clock
voltage conditions. (when used with substrate bias external adjustment, set the substrate voltage to the
value indicated on the device.)
2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical
black level (OB) is used as the reference for the signal output, which is taken as the value of Y signal output
or chroma signal output of the measurement system.
Color coding of this image sensor & Composition of luminance (Y) and chroma (color difference) signals
As shown in the left figure, fields are read out. The charge is
mixed by pairs such as A1 and A2 in the A field. (pairs such
as B in the B field)
As a result, the sequence of charges output as signals from
the horizontal shift register (Hreg) is, for line A1, (G + Cy),
(Mg + Ye), (G + Cy), and (Mg + Ye).
These signals are processed to form the Y signal and chroma (color difference) signal. The Y signal is formed
by adding adjacent signals, and the chroma signal is formed by subtracting adjacent signals. In other words,
the approximation:
Y = {(G + Cy) + (Mg + Ye)}
1/2
= 1/2 {2B + 3G + 2R}
is used for the Y signal, and the approximation:
R Y = {(Mg + Ye) (G + Cy)}
= {2R G}
is used for the chroma (color difference) signal. For line A2, the signals output from Hreg in sequence are
(Mg + Cy), (G + Ye), (Mg + Cy), (G + Ye).
The Y signal is formed from these signals as follows:
Y = {(G + Ye) + (Mg + Cy)}
1/2
= 1/2 {2B + 3G + 2R}
This is balanced since it is formed in the same way as for line A1.
In a like manner, the chroma (color difference) signal is approximated as follows:
(B Y) = {(G + Ye) (Mg + Cy)}
= {2B G}
In other words, the chroma signal can be retrieved according to the sequence of lines from R Y and (B Y)
in alternation. This is also true for the B field.
Cy
Ye
Cy
Ye
G
Mg
G
Mg
Cy
Ye
Cy
Ye
Mg
G
Mg
G
B
A1
A2
Hreg
Color Coding Diagram
12
ICX419AKL
Definition of standard imaging conditions
1) Standard imaging condition
I
:
Use a pattern box (luminance 706cd/m
2
, color temperature of 3200K halogen source) as a subject. (Pattern
for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter and
image at F5.6. The luminous intensity to the sensor receiving surface at this point is defined as the standard
sensitivity testing luminous intensity.
2) Standard imaging condition
II
:
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.
Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted
to the value indicated in each testing item by the lens diaphragm.
1. Sensitivity
Set to standard imaging condition
I
. After selecting the electronic shutter mode with a shutter speed of
1/250s, measure the Y signal (Ys) at the center of the screen and substitute the value into the following
formula.
S = Ys
[mV]
2. Saturation signal
Set to standard imaging condition
II
. After adjusting the luminous intensity to 10 times the intensity with
average value of the Y signal output, 200mV, measure the minimum value of the Y signal.
3. Smear
Set to standard imaging condition
II
. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to
500 times the intensity with average value of the Y signal output, 200mV. When the readout clock is
stopped and the charge drain is executed by the electronic shutter at the respective H blankings, measure
the maximum value YSm [mV] of the Y signal output and substitute the value into the following formula.
Sm = 20
log
4. Video signal shading
Set to standard imaging condition
II
. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity so
that the average value of the Y signal output is 200mV. Then measure the maximum (Ymax [mV]) and
minimum (Ymin [mV]) values of the Y signal and substitute the values into the following formula.
SHy = (Ymax Ymin)/200
100 [%]
5. Uniformity between video signal channels
Set to standard imaging condition
II
. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then measure the maximum (Crmax, Cbmax [mV]) and minimum (Crmin, Cbmin
[mV]) values of the R Y and B Y channels of the chroma signal and substitute the values into the
following formula.
Sr = | (Crmax Crmin)/200 |
100 [%]
Sb = | (Cbmax Cbmin)/200 |
100 [%]
6. Dark signal
Measure the average value of the Y signal output (Ydt [mV]) with the device ambient temperature 60C and
the device in the light-obstructed state, using the horizontal idle transfer level as a reference.
250
50
1
10
1
500
YSm
200
[dB] (1/10V method conversion value)
13
ICX419AKL
7. Dark signal shading
After measuring 6, measure the maximum (Ydmax [mV]) and minimum (Ydmin [mV]) values of the dark
signal output and substitute the values into the following formula.
Ydt = Ydmax Ydmin [mV]
8. Flicker
1) Fy
Set to standard imaging condition
II
. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then measure the difference in the signal level between fields (
Yf [mV]). Then
substitute the value into the following formula.
Fy = (
Yf/200)
100 [%]
2) Fcr, Fcb
Set to standard imaging condition
II
. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, insert an R or B filter, and then measure both the difference in the signal level between
fields of the chroma signal (
Cr,
Cb) as well as the average value of the chroma signal output (CAr, CAb).
Substitute the values into the following formula.
Fci = (
Ci/CAi)
100 [%] (i = r, b)
9. Line crawls
Set to standard imaging condition
II
. Adjust the luminous intensity so that the average value of the Y signal
output is 200mV, and then insert a white subject and R, G, and B filters and measure the difference
between Y signal lines for the same field (
Ylw,
Ylr,
Ylg,
Ylb [mV]). Substitute the values into the
following formula.
Lci = (
Yli/200)
100 [%] (i = w, r, g, b)
10. Lag
Adjust the Y signal output value generated by strobe light to 200mV. After setting the strobe light so that it
strobes with the following timing, measure the residual signal (Ylag). Substitute the value into the following
formula.
Lag = (Ylag/200)
100 [%]
Light
Y signal output 200mV
Ylag (lag)
FLD
V1
Strobe light
timing
Output
14
ICX419AKL
Drive Circuit 1 (substrate bias internal generation mode)
22/16V
0.01
9V
3.3/16V
3.3/20V
0.01
1/35V
1
100
H
1
H
2
NC
RG
RD
GND
GND
NC
V
DSUB
NC
22/20V
CCD OUT
[
A]
15V
XSUB
XV2
XV1
XSG1
XV3
XSG2
XV4
H
2
H
1
RG
100k
0.01
CXD1267AN
1
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
13
12
11
3.9k
V
4
V
3
V
2
SUB
GND
V
L
GND
V
DD
V
OUT
V
1
ICX419
(BOTTOM VIEW)
1
2
3
4
5
6
7
8
9
10
20 19 18 17 16 15 14 13 12 11
1M
15
ICX419AKL
Drive Circuit 2 (substrate bias external adjustment mode)
22/16V
0.01
9V
3.3/16V
3.3/20V
0.01
1/35V
0.1
100
H
1
H
2
NC
RG
RD
GND
GND
NC
V
DSUB
NC
22/20V
CCD OUT
[
A]
15V
XSUB
XV2
XV1
XSG1
XV3
XSG2
XV4
H
2
H
1
RG
27k
0.01
CXD1267AN
1
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
13
12
11
3.9k
0.1
39k
15k
47k
15k
270k
100k
1/35V
1/35V
0.1
V
4
V
3
V
2
SUB
GND
V
L
GND
V
DD
V
OUT
V
1
ICX419
(BOTTOM VIEW)
1
2
3
4
5
6
7
8
9
10
20 19 18 17 16 15 14 13 12 11
1M
56k
16
ICX419AKL
Spectral Sensitivity Characteristics (Excludes lens characteristics and light source characteristics)
Sensor Readout Clock Timing Chart
1.0
0.8
0.6
0.4
0.2
0
400
450
500
Cy
Ye
Mg
G
550
Wave Length [nm]
Relativ
e Response
600
650
700
Odd Field
Even Field
V1
V2
V3
V4
V1
V2
V3
V4
2.5
2.6 2.5 2.5
33.6
1.5
0.2
Unit: s
17
ICX419AKL
Drive Timing Chart (Vertical Sync)
FLD
VD
BLK
HD
V1
V2
V3
V4
CCD
OUT
620
625
1
2
3
4
5
15
20
25
310
320
335
330
340
581
582
1 3 5
2 4 6
1 3 5
2 4 6
582
581
2
1
4
3
6
5
10
315
325
2
1
4
3
6
5
18
ICX419AKL
Drive Timing Chart (Horizontal Sync)
745
750
1
3
5
10
20
30
40
1 2 3
5
10
20
22
1 2 3 1 2 3
10
20
752
HD
BLK
H1
H2
RG
V1
V2
V3
V4
SUB
19
ICX419AKL
Notes on Handling
1) Static charge prevention
CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following
protective measures.
a) Either handle bare handed or use non-chargeable gloves, clothes or material.
Also use conductive shoes.
b) When handling directly use an earth band.
c) Install a conductive mat on the floor or working table to prevent the generation of static electricity.
d) Ionized air is recommended for discharge when handling CCD image sensor.
e) For the shipment of mounted substrates, use boxes treated for the prevention of static charges.
2) Soldering
a) Make sure the package temperature does not exceed 80C.
b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a ground 30W
soldering iron and solder each pin in less than 2 seconds. For repairs and remount, cool sufficiently.
c) To dismount an image sensor, do not use a solder suction equipment. When using an electric desoldering
tool, use a thermal controller of the zero cross On/Off type and connect it to ground.
3) Dust and dirt protection
Image sensors are packed and delivered by taking care of protecting its glass plates from harmful dust and
dirt. Clean glass plates with the following operation as required, and use them.
a) Perform all assembly operations in a clean room (class 1000 or less).
b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should
dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized
air is recommended.)
c) Clean with a cotton bud and ethyl alcohol if the grease stained. Be careful not to scratch the glass.
d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when
moving to a room with great temperature differences.
e) When a protective tape is applied before shipping, just before use remove the tape applied for
electrostatic protection. Do not reuse the tape.
4) Installing (attaching)
a) Remain within the following limits when applying a static load to the package. Do not apply any load more
than 0.7mm inside the outer perimeter of the glass portion, and do not apply any load or impact to limited
portions. (This may cause cracks in the package.)
b) If a load is applied to the entire surface by a hard component, bending stress may be generated and the
package may fracture, etc., depending on the flatness of the ceramic portions. Therefore, for installation,
use either an elastic load, such as a spring plate, or an adhesive.
39N
Lower ceramic
Upper ceramic
Compressive strength
Low melting
point glass
29N
Shearing strength
29N
Tensile strength
0.9Nm
Torsional strength
20
ICX419AKL
c) The adhesive may cause the marking on the rear surface to disappear, especially in case the regulated
voltage value is indicated on the rear surface. Therefore, the adhesive should not be applied to this area,
and indicated values should be transferred to other locations as a precaution.
d) The upper and lower ceramic are joined by low melting point glass. Therefore, care should be taken not to
perform the following actions as this may cause cracks.
Applying repeated bending stress to the outer leads.
Heating the outer leads for an extended period with a soldering iron.
Rapidly cooling or heating the package.
Applying any load or impact to a limited portion of the low melting point glass using tweezers or other
sharp tools.
Prying at the upper or lower ceramic using the low melting point glass as a fulcrum.
Note that the same cautions also apply when removing soldered products from boards.
e) Acrylate anaerobic adhesives are generally used to attach CCD image sensors. In addition, cyano-
acrylate instantaneous adhesives are sometimes used jointly with acrylate anaerobic adhesives. (reference)
5) Others
a) Do not expose to strong light (sun rays) for long periods, color filters will be discolored. When high
luminance objects are imaged with the exposure level control by electronic-iris, the luminance of the
image-plane may become excessive and discolor of the color filter will possibly be accelerated. In such a
case, it is advisable that taking-lens with the automatic-iris and closing of the shutter during the power-off
mode should be properly arranged. For continuous using under cruel condition exceeding the normal
using condition, consult our company.
b) Exposure to high temperature or humidity will affect the characteristics. Accordingly avoid storage or
usage in such conditions.
21
ICX419AKL
Package Outline Unit: mm
Son
y Cor
por
ation
20 pin DIP (600mil)
0.7
3
11.55
3
0.55
9.0
7.55
V
H
14.2
1
10
11
20
13.1
15.24
0 to 9
1.4
0.25
(R0.7)
(1.0)
11
10
17.6
1.4
(4.0)
(1.7)
3.26 0.3
0.7
3
14.6
4.0 0.3
1.27
0.46
0.8
0.83
0.4
0.4
1.778
0.3
20
1
C
B
~
~
B'
~
M
A
18.0 0.4
15.1 0.3
PACKAGE STRUCTURE
PACKAGE MATERIAL
LEAD TREATMENT
LEAD MATERIAL
PACKAGE MASS
DRAWING NUMBER
Cer-DIP
TIN PLATING
42 ALLOY
2.6g
AS-B14(E)
1. "A" is the center of the effective image area.
2. The two points "B" of the package are the horizontal reference.
The point "B'" of the package is the vertical reference.
3. The bottom "C" of the package is the height reference.
4. The center of the effective image area, relative to "B" and "B'" is
(H, V) = (9.0, 7.55) 0.15mm.
5. The rotation angle of the effective image area relative to H and V is 1.
6. The height from the bottom "C" to the effective image area is 1.41 0.15mm.
7. The tilt of the effective image area relative to the bottom "C" is less than 60m.
8. The thickness of the cover glass is 0.75mm, and the refractive index is 1.5.
9. The notch and the hole on the bottom must not be used for reference of fixing.