ChipFind - документация

Электронный компонент: LCP02-150B1

Скачать:  PDF   ZIP
1/8
A.S.D.TM
LCP02-150B1
s
Protection IC recommended for ringing SLICs.
s
Wide firing voltage range: from -110V to +95V.
s
Low gate triggering current: I
G
= 5mA max.
s
Peak pulse current: I
PP
= 30A (10/1000s) .
s
Holding current: I
H
= 150mA min.
s
UL497B approved (file E136224)
FEATURES
SO-8 WIDE
The LCP02-150B1 has been developed to protect
SLICs operating on both negative and positive bat-
tery supplies, as well as on high voltage SLICs. It
provides crowbar mode protection for both TIP and
RING lines. The surge suppression is assumed for
each wire by two thyristor structures, one dedi-
cated to positive surges the second one for nega-
tive surges. Both positive and negative threshold
levels are programmable by two gates (Gn and
Gp). The use of transistors decreases the battery
currents during surge suppression.
The LCP02-150B1 has high Bellcore Core, ITU-T
and FCC Part 68 lightning surge ratings, ensuring
rugged performance in the field. In addition, it is
also specified to assist a designer to comply with
UL1950, IEC950 and CSA C22.2. It is UL 497B
approved (file E136224), and has UL94-V0 resin
approved
DESCRIPTION
September 2000 - Ed: 4A
Gn
TIP
Gp
GND
RING
FUNCTIONAL DIAGRAM
TM: ASD is trademarks of STMicroelectronics.
PROTECTION IC
FOR RINGING SLICS
s
Dual battery supply voltage SLICs
- negative battery supply configuration
- negative & positive battery supply configuration
s
Central Office (CO)
s
Private Branch Exchange (PBX)
s
Digital Loop Carrier (DLC)
s
Asymmetrical Digital Subscriber Line (ADSL G.Lite)
s
Fiber in the Loop (FITL)
s
Wireless Local Loop (WLL)
s
Hybrid Fiber Coax (HFC)
s
ISDN Terminal Adapter
s
Cable modem
MAIN APPLICATIONS
GND
TIP
RING
G
P
G
n
NC
NC
GND
PIN-OUT CONFIGURATION
LCP02-150B1
2/8
Peak surge
voltage
(V)
Voltage
waveform
(s)
Required
peak current
(A)
Current
waveform
(s)
Minimum serial
resistor to meet
standard ( )
ITU-T K20
4000
1000
10/700
10/700
100
25
5/310
5/310
50
0
ITU-T K21
4000
1500
10/700
10/700
100
37.5
5/310
5/310
50
0
VDE0433
2000
10/700
50
5/310
5
VDE0878
2000
1.2/50
50
1/20
0
IEC61000-4-5
level 3
level 4
10/700
1.2/50
50
100
5/310
8/20
5
25
FCC Part 68
lightning surge type A
1500
800
10/160
10/560
200
100
10/160
10/560
20
15
FCC Part 68
lightning surge type B
1000
9/720
25
5/320
0
BELLCORE
GR-1089-CORE
First level
2500
1000
2/10
10/1000
500
100
2/10
10/1000
20
25
BELLCORE
GR-1089-CORE
Second level
5000
2/10
500
2/10
40
BELLCORE
GR-1089-CORE
Intrabuilding
800
1500
2/10
2/10
100
100
2/10
2/10
0
0
COMPLIES WITH FOLLOWING STANDARDS
Symbol
Parameter
Value
Unit
I
PP
Peak pulse current
10/1000
s
5/310
s
1/20
s
30
45
65
A
I
TSM
Non repetitive surge peak on-state current
(F = 50Hz)
t
p
= 0.2 s
t
p
= 1s
t
p
= 15 min
5.5
4.2
1.5
A
V
GN
max
V
GP
max
V
bat
max
Maximum negative battery voltage range
Maximum positive battery voltage range
Total battery supply voltage
See fig.1
-110 to 0
0 to +95
190
V
T
op
Operating temperature range (see note 1)
-20 to +85
C
T
stg
Storage temperature range
- 55 to + 150
C
T
L
Lead solder temperature (10s duration)
260
C
ABSOLUTE MAXIMUM RATINGS (T
amb
= 25 C)
Note 1: Within the Top range, the LCP02-150B1 keeps on operating.
The impacts of the ambient temperature are given by derating
curves.
100
50
% I
PP
t
t
r
p
0
t
LCP02-150B1
3/8
Symbol
Parameter
Value
Unit
R
th (j-a)
Junction to ambient
150
C/W
THERMAL RESISTANCE
TIP
RING
G
P
G
n
GND
NC
NC
GND
1
TIP
RING
Gn from -110V to +0V
Gp from +0V to +95V
Vbat
190V
Gn connected to negative supply voltage
Gp connected to positive supply voltage
V t: differential voltage between V
and V
ba
Gp
Gn
Fig. 1: Test circuit
LCP02-150B1
4/8
Symbol
Parameter
Test conditions
Min.
Max.
Unit
I
Gn
Negative gate trigger
current
V
Gn/GND
= -60V
Measured at 50Hz
5
mA
I
H-
Holding current
(see fig.2)
Go-No Go test, V
Gn
= -60V
150
mA
I
RGL-
Reverse leakage
current Gn/Line
Tj = 25C, V
Gn/line
= -190V
5
A
V
DGL-
Dynamic switching
voltage Gn / Line
(see note 2)
V
Gn/GND
= -60V
10/1000s 1kV R
P
= 25
I
PP
= 30A
10/700s 2kV R
P
= 25
I
PP
= 30A
1.2/50s
2kV R
P
= 25
I
PP
= 30A
18
8
15
V
1 - PARAMETERS RELATED TO THE NEGATIVE SUPPRESSOR
Symbol
Parameter
Test conditions
Min.
Max.
Unit
I
Gp
Positive gate trigger
current
V
Gp/GND
= 60V
Measured at 50Hz
5
mA
I
RGL+
Reverse leakage
current Gp/LINE
Tj = 25C, V
Gp/line
= +190V
5
A
V
DGL+
Dynamic switching
voltage Gp / Line
(see note 2)
V
Gp/GND
= +60V
10/1000s 1kV R
P
= 25
I
PP
= 30A
10/700s 2kV R
P
= 25
I
PP
= 30A
1.2/50s
2kV R
P
= 25
I
PP
= 30A
18
8
35
V
2 - PARAMETERS RELATED TO THE POSITIVE SUPPRESSOR
Symbol
Parameter
Test conditions
Typ.
Max.
Unit
I
R
Reverse
leakage current
Tj = 25C, V
LINE
= +90V, V
GP/LINE
= +1V
Tj = 25C, V
LINE
= -105V, V
GN/LINE
= -1V
5
5
A
C
off
Capacitance
LINE/GND
V
R
= -3V, F =1MHz, V
Gp
= 60V, V
Gn
= -60V
60
pF
Note 2: The V
DGL
value is the difference between the peak line voltage during the surge and the programmed gate voltage.
3 - PARAMETERS RELATED TO LINE/GND
ELECTRICAL CHARACTERISTICS (T
amb
= 25C)
LCP02-150B1
5/8
-20
0
20
40
60
80
100
0.4
0.6
0.8
1
1.2
1.4
1.6
T (C)
IH (T) / IH(25C)
Fig. 2: Relative variation of holding current versus
junction temperature.
0.01
0.1
1
10
100
1000
0
2
4
6
8
10
t (s)
I
(A)
TSM
Fig. 3: Maximum non repetitive surge peak on
state current versus overload duration (with 50Hz
sinusoidal wave and initial junction temperature
equal to +25C).
20
40
60
80
100
0
10
20
30
40
50
60
70
Vline (V)
C (pF)
line +
line -
Fig. 4: Capacitance versus reverse applied
voltage (typical values) with V
GN
= -90V and
V
GP
= +90V.