ChipFind - документация

Электронный компонент: 74AC11352N

Скачать:  PDF   ZIP
74AC11352
DUAL 4LINE TO 1LINE DATA SELECTOR/MULTIPLEXER
SCAS167 DECEMBER 1991 REVISED APRIL 1993
Copyright
1993, Texas Instruments Incorporated
1
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 772511443
Permit Multiplexing from N Lines to 1 Line
Perform Parallel-to-Serial Conversion
Strobe Line Provided for Cascading
(N Lines to N Lines)
Flow-Through Architecture Optimizes PCB
Layout
Center-Pin V
CC
and GND Pin Configurations
Minimize High-Speed Switching Noise
EPIC
TM
(Enhanced-Performance Implanted
CMOS) 1-
m Process
500-mA Typical Latch-Up Immunity at 125
C
Package Options Include Plastic
Small-Outline Packages, and Standard
Plastic 300-mil DIPs
description
Each of these data selectors/multiplexers contains inverters and drivers to supply full binary-decoding data
selection to the AND-OR gates. Separate strobe output-enable (OE) inputs are provided for each of the two
four-line sections.
The 74AC11352 is characterized for operation from 40
C to 85
C.
FUNCTION TABLE
(each multiplexer)
SELECT INPUTS
DATA INPUTS
STROBE
OUTPUT
B
A
C0
C1
C2
C3
OE
Y
X
X
X
X
X
X
H
H
L
L
L
X
X
X
L
H
L
L
H
X
X
X
L
L
L
H
X
L
X
X
L
H
L
H
X
H
X
X
L
L
H
L
X
X
L
X
L
H
H
L
X
X
H
X
L
L
H
H
X
X
X
L
L
H
H
H
X
X
X
H
L
L
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
A
B
1Y
GND
2Y
1OE
2OE
2C3
1C0
1C1
1C2
1C3
V
CC
2C0
2C1
2C2
D OR N PACKAGE
(TOP VIEW)
EPIC is a trademark of Texas Instruments Incorporated.
74AC11352
DUAL 4LINE TO 1LINE DATA SELECTOR/MULTIPLEXER
SCAS167 DECEMBER 1991 REVISED APRIL 1993
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 772511443
logic symbol
MUX
0
16
1C0
1
15
1C1
2
14
1C2
3
13
1C3
EN
6
0
1
A
1Y
3
1
2
B
11
2C0
10
2C1
9
2C2
8
2C3
7
2Y
5
1OE
2OE
G
0
3
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram (positive logic)
1OE
2OE
1C0
1C1
1C2
1C3
B
A
2C1
2C2
2C3
2C0
1Y
2Y
3
5
6
16
15
14
13
2
1
11
10
9
8
7
Data 1
Data 2
Select
74AC11352
DUAL 4LINE TO 1LINE DATA SELECTOR/MULTIPLEXER
SCAS167 DECEMBER 1991 REVISED APRIL 1993
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 772511443
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(see Note 1)
0.5 V to V
CC
+ 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
(see Note 1)
0.5 V to V
CC
+ 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
CC
)
20 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
)
50 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
(V
O
= 0 to V
CC
)
50 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through V
CC
or GND pins
100 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range
65
C to 150
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
recommended operating conditions (see Note 2)
MIN
NOM
MAX
UNIT
VCC
Supply voltage
3
5
5.5
V
VCC = 3 V
2.1
VIH
High-level input voltage
VCC = 4.5 V
3.15
V
VCC = 5.5 V
3.85
VCC = 3 V
0.9
VIL
Low-level input voltage
VCC = 4.5 V
1.35
V
VCC = 5.5 V
1.65
VI
Input voltage
0
VCC
V
VO
Output voltage
0
VCC
V
VCC = 3 V
4
IOH
High-level output current
VCC = 4.5 V
24
mA
VCC = 5.5 V
24
VCC = 3 V
12
IOL
Low-level output current
VCC = 4.5 V
24
mA
VCC = 5.5 V
24
t/
v
Input transition rise or fall rate
0
10
ns/V
TA
Operating free-air temperature
40
85
C
NOTE 2: Unused or floating inputs must be held high or low.
74AC11352
DUAL 4LINE TO 1LINE DATA SELECTOR/MULTIPLEXER
SCAS167 DECEMBER 1991 REVISED APRIL 1993
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 772511443
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25
C
MIN
MAX
UNIT
PARAMETER
TEST CONDITIONS
VCC
MIN
TYP
MAX
MIN
MAX
UNIT
3 V
2.9
2.9
IOH = 50
A
4.5 V
4.4
4.4
5.5 V
5.4
5.4
VOH
IOH = 4 mA
3 V
2.58
2.48
V
VOH
I
24
A
4.5 V
3.94
3.8
V
IOL = 24 mA
5.5 V
4.94
4.8
IOH = 50 mA
5.5 V
IOH = 75 mA
5.5 V
3.85
3 V
0.1
0.1
IOL = 50
A
4.5 V
0.1
0.1
5.5 V
0.1
0.1
VOL
IOL = 12 mA
3 V
0.36
0.44
V
VOL
IOL = 24 mA
4.5 V
0.36
0.44
V
IOL = 24 mA
5.5 V
0.36
0.44
IOL = 50 mA
5.5 V
IOL = 75 mA
5.5 V
1.65
II
VI = VCC or GND
5.5 V
0.1
1
A
IOZ
VO = VCC or GND
5.5 V
0.5
5
A
ICC
VI = VCC or GND,
IO = 0
5.5 V
8
80
A
Ci
VI = VCC or GND
5 V
3.5
pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V
0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
TA = 25
C
MIN
MAX
UNIT
PARAMETER
(INPUT)
(OUTPUT)
MIN
TYP
MAX
MIN
MAX
UNIT
tPLH
A or B
Y
2.5
7.1
9
2.5
10
ns
tPHL
A or B
Y
3
7.2
9
3
10.8
ns
tPLH
Any C
Y
2.3
6.7
8.1
2.3
8.9
ns
tPHL
Any C
Y
3
6.8
8.1
3
9.5
ns
tPLH
OE
Y
2
5.3
6.6
2
7.2
ns
tPHL
OE
Y
2.2
5.6
6.8
2.2
8.3
ns
74AC11352
DUAL 4LINE TO 1LINE DATA SELECTOR/MULTIPLEXER
SCAS167 DECEMBER 1991 REVISED APRIL 1993
5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 772511443
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V
0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
TA = 25
C
MIN
MAX
UNIT
PARAMETER
(INPUT)
(OUTPUT)
MIN
TYP
MAX
MIN
MAX
UNIT
tPLH
A or B
Y
2.2
4.5
6.2
2.2
7.4
ns
tPHL
A or B
Y
2.5
5.3
7.5
2.5
8.9
ns
tPLH
Any C
Y
2
4.2
5.7
2
6.6
ns
tPHL
Any C
Y
2.5
5.1
6.8
2.5
7.9
ns
tPLH
OE
Y
1.7
3.6
5.1
1.7
5.5
ns
tPHL
OE
Y
2.2
4.5
5.9
2.2
7.2
ns
operating characteristics, V
CC
= 5 V, T
A
= 25
C
PARAMETER
TEST CONDITIONS
TYP
UNIT
Cpd
Power dissipation capacitance
CL = 50 pF,
f = 1 MHz
30
pF
PARAMETER MEASUREMENT INFORMATION
tPHL
tPLH
50% VCC
VCC
0
50% VCC
50% VCC
VOH
VOL
Input
(see Note B)
Output
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
From Output
Under Test
CL = 50 pF
(see Note A)
500
LOAD CIRCUIT
50% VCC
NOTES: A. CL includes probe and jig capacitance.
B. Input pulses are supplied by generators having the following characteristics: PRR
10 MHz, ZO = 50
, tr = 3 ns, tf = 3 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI's standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL
APPLICATIONS"). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER'S RISK.
In order to minimize risks associated with the customer's applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI's publication of information regarding any third
party's products or services does not constitute TI's approval, warranty or endorsement thereof.
Copyright
1998, Texas Instruments Incorporated