ChipFind - документация

Электронный компонент: 74AC11353

Скачать:  PDF   ZIP
74AC11353
DUAL 1OR4 DATA SELECTOR/MULTIPLEXER
SCAS044A JUNE 1988 REVISED APRIL 1993
Copyright
1993, Texas Instruments Incorporated
Revision Information
1
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
Inverting Version of 74AC11253
Permits Multiplexing from N Lines to 1 Line
Performs Parallel-to-Serial Conversion
Flow-Through Architecture Optimizes PCB
Layout
Center-Pin V
CC
and GND Configurations
Minimize High-Speed Switching Noise
EPIC
TM
(Enhanced-Performance Implanted
CMOS) 1-
m Process
Package Options Include Plastic
Small-Outline Packages, and Standard
Plastic 300-mil DIPs
description
Each of these data selectors/multiplexers contains inverters and drivers to supply full binary decoding data
selection to the AND-OR gates. Separate strobe output-enable (1OE or 2OE) inputs are provided for each of
the two four-line sections.
The 3-state outputs can interface with and drive data lines of bus-organized systems. With all but one of the
common outputs disabled (at a high-impedance state), the low impedance of the single enabled output will drive
the bus line to a high or low logic level. Each output has its own strobe. The output is disabled when its strobe
is high.
The 74AC11353 is characterized for operation from 40
C to 85
C.
FUNCTION TABLE
SELECT
INPUTS
DATA INPUTS
STROBE
OE
OUTPUT
Y
B
A
C0
C1
C2
C3
OE
Y
X
X
X
X
X
X
H
Z
L
L
L
X
X
X
L
H
L
L
H
X
X
X
L
L
L
H
X
L
X
X
L
H
L
H
X
H
X
X
L
L
H
L
X
X
L
X
L
H
H
L
X
X
H
X
L
L
H
H
X
X
X
L
L
H
H
H
X
X
X
H
L
L
D OR N PACKAGE
(TOP VIEW)
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
A
B
1Y
GND
2Y
1OE
2OE
2C3
1C0
1C1
1C2
1C3
V
CC
2C0
2C1
2C2
EPIC is a trademark of Texas Instruments Incorporated.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
74AC11353
DUAL 1OR4 DATA SELECTOR/MULTIPLEXER
SCAS044A JUNE 1988 REVISED APRIL 1993
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
logic symbol
MUX
EN
6
0
16
1C0
1
15
1C1
2
14
1C2
3
13
1C3
0
1
A
1Y
3
1
2
B
G
0
3
7
11
2C0
10
2C1
9
2C2
8
2C3
2Y
5
1OE
2OE
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram (positive logic)
1OE
2OE
1C0
1C1
1C2
1C3
B
A
2C1
2C2
2C3
2C0
1Y
2Y
3
5
6
16
15
14
13
2
1
11
10
9
8
7
Data 1
Data 2
Select
74AC11353
DUAL 1OR4 DATA SELECTOR/MULTIPLEXER
SCAS044A JUNE 1988 REVISED APRIL 1993
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(see Note 1)
0.5 V to V
CC
+ 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
(see Note 1)
0.5 V to V
CC
+ 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
CC
)
20 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
)
50 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
(V
O
= 0 to V
CC
)
50 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through V
CC
or GND pins
100 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range
65
C to 150
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
recommended operating conditions
MIN
NOM
MAX
UNIT
VCC
Supply voltage
3
5
5.5
V
VCC = 3 V
2.1
VIH
High-level input voltage
VCC = 4.5 V
3.15
V
VCC = 5.5 V
3.85
VCC = 3 V
0.9
VIL
Low-level input voltage
VCC = 4.5 V
1.35
V
VCC = 5.5 V
1.65
VI
Input voltage
0
VCC
V
VO
Output voltage
0
VCC
V
VCC = 3 V
4
IOH
High-level output current
VCC = 4.5 V
24
mA
VCC = 5.5 V
24
VCC = 3 V
12
IOL
Low-level output current
VCC = 4.5 V
24
mA
VCC = 5.5 V
24
t/
v
Input transition rise or fall rate
0
10
ns/V
TA
Operating free-air temperature
40
85
C
74AC11353
DUAL 1OR4 DATA SELECTOR/MULTIPLEXER
SCAS044A JUNE 1988 REVISED APRIL 1993
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25
C
MIN
MAX
UNIT
PARAMETER
TEST CONDITIONS
VCC
MIN
TYP
MAX
MIN
MAX
UNIT
3 V
2.9
2.9
IOH = 50
A
4.5 V
4.4
4.4
5.5 V
5.4
5.4
VOH
IOH = 4 mA
3 V
2.58
2.48
V
I
24
A
4.5 V
3.94
3.8
IOH = 24 mA
5.5 V
4.94
4.8
IOH = 75 mA
5.5 V
3.85
3 V
0.1
0.1
IOL = 50
A
4.5 V
0.1
0.1
5.5 V
0.1
0.1
VOL
IOL = 12 mA
3 V
0.36
0.44
V
IOL = 24 mA
4.5 V
0.36
0.44
IOL = 24 mA
5.5 V
0.36
0.44
IOL = 75 mA
5.5 V
1.65
II
VI = VCC or GND
5.5 V
0.1
1
A
IOZ
VO = VCC or GND
5.5 V
0.5
5
A
ICC
VI = VCC or GND,
IO = 0
5.5 V
8
80
A
Ci
VI = VCC or GND
5 V
3.5
pF
CO
VO = VCC or GND
5 V
8
pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V
0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
TA = 25
C
MIN
MAX
UNIT
PARAMETER
(INPUT)
(OUTPUT)
MIN
TYP
MAX
MIN
MAX
UNIT
tPLH
A or B
Y
1.5
7
9.6
1.5
10.7
ns
tPHL
A or B
Y
1.5
7.2
9.8
1.5
10.9
ns
tPLH
Any C
Y
1.5
6.5
8.6
1.5
9.6
ns
tPHL
Any C
Y
1.5
6.6
8.7
1.5
9.7
ns
tPZH
OE
Y
1.5
4.4
6
1.5
6.6
ns
tPZL
OE
Y
1.5
5.4
7.2
1.5
7.9
ns
tPHZ
OE
Y
1.5
4.8
6.2
1.5
6.5
ns
tPLZ
OE
Y
1.5
4.9
6.3
1.5
6.6
ns
74AC11353
DUAL 1OR4 DATA SELECTOR/MULTIPLEXER
SCAS044A JUNE 1988 REVISED APRIL 1993
5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V
0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
TA = 25
C
MIN
MAX
UNIT
PARAMETER
(INPUT)
(OUTPUT)
MIN
TYP
MAX
MIN
MAX
UNIT
tPLH
A or B
Y
1.5
4.5
6.6
1.5
7.4
ns
tPHL
A or B
Y
1.5
4.6
6.9
1.5
7.6
ns
tPLH
Any C
Y
1.5
4
5.9
1.5
6.6
ns
tPHL
Any C
Y
1.5
4.2
6.1
1.5
6.8
ns
tPZH
OE
Y
1.5
2.9
4.4
1.5
4.8
ns
tPZL
OE
Y
1.5
3.4
5.1
1.5
5.6
ns
tPHZ
OE
Y
1.5
4.4
5.8
1.5
6.1
ns
tPLZ
OE
Y
1.5
4.1
5.5
1.5
5.8
ns
operating characteristics, V
CC
= 5 V, T
A
= 25
C
PARAMETER
TEST CONDITIONS
TYP
UNIT
C d
Power dissipation capacitance per multiplexer
Outputs enabled
CL = 50 pF
f = 1 MHz
31
pF
Cpd
Power dissipation capacitance per multiplexer
Outputs disabled
CL = 50 pF,
f = 1 MHz
12
pF
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
CL = 50 pF
LOAD CIRCUIT FOR OUTPUTS
S1
2
VCC
Open
GND
500
500
TEST
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
S1
Open
2
VCC
GND
Output
Control
(low-level
enabling)
Output
Waveform 1
S1 at 2
VCC
(see Note C)
Output
Waveform 2
S1 at GND
(see Note C)
VOL
VOH
tPZL
tPZH
tPLZ
tPHZ
50%
50%

VCC
0 V
50% VCC
0 V
VCC
(see Note A)
50% VCC
20% VCC
80% VCC
tPLH
tPHL
50%
50%
0 V
50% VCC
50% VCC
VOH
VOL
Input
(see Note B)
Output
(see Note D)
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
VCC
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR
10 MHz, Zo = 50
, tr
3 ns, tf
3 ns.
For testing pulse duration: tr = tf = 1 to 3 ns. Pulse polarity can be either high-to-low-to-high or low-to-high-to-low.
C. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
D. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI's standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL
APPLICATIONS"). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER'S RISK.
In order to minimize risks associated with the customer's applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI's publication of information regarding any third
party's products or services does not constitute TI's approval, warranty or endorsement thereof.
Copyright
1998, Texas Instruments Incorporated