ChipFind - документация

Электронный компонент: UA7915KTER

Скачать:  PDF   ZIP
A7900 SERIES
NEGATIVE VOLTAGE REGULATORS
SLVS058D - JUNE 1976 - REVISED APRIL 2004
1
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
D
3-Terminal Regulators
D
Output Current Up To 1.5 A
D
No External Components
D
Internal Thermal Overload Protection
D
High-Power Dissipation Capability
D
Internal Short-Circuit Current Limiting
D
Output Transistor Safe-Area Compensation
description/ordering information
This series of fixed-negative-voltage
integrated-circuit voltage regulators is designed
to complement Series
A7800 in a wide range of
applications. These applications include on-card
regulation for elimination of noise and distribution
problems associated with single-point regulation. Each of these regulators can deliver up to 1.5 A of output
current. The internal current limiting and thermal shutdown features of these regulators essentially make them
immune to overload. In addition to use as fixed-voltage regulators, these devices can be used with external
components to obtain adjustable output voltages and currents and also as the power-pass element in precision
regulators.
ORDERING INFORMATION
TJ
VO(NOM)
(V)
PACKAGE
ORDERABLE
PART NUMBER
TOP-SIDE
MARKING
-15
Power Flex (KTE)
Reel of 2000
A7915CKTER
A7915C
-15
TO-220, short shoulder (KCS)
Tube of 50
A7915CKCS
A7915C
-12
Power Flex (KTE)
Reel of 2000
A7912CKTER
A7912C
0
C to 125
C
-12
TO-220, short shoulder (KCS)
Tube of 50
A7912CKCS
A7912C
0
C to 125
C
-8
Power Flex (KTE)
Reel of 2000
A7908CKTER
A7908C
-8
TO-220, short shoulder (KCS)
Tube of 50
A7908CKCS
A7908C
-5
Power Flex (KTE)
Reel of 2000
A7905CKTER
A7905C
-5
TO-220, short shoulder (KCS)
Tube of 50
A7905CKCS
A7905C
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright
2004, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
KTE PACKAGE
(TOP VIEW)
OUTPUT
COMMON
INPUT
INPUT
INPUT
OUTPUT
KCS (TO-220) PACKAGE
(TOP VIEW)
COMMON
INPUT
A7900 SERIES
NEGATIVE VOLTAGE REGULATORS
SLVS058D - JUNE 1976 - REVISED APRIL 2004
2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
schematic
COMMON
OUTPUT
12 V to 18 V
5 V to 8 V
6.2 V
5 k
20 k
0.2 k
INPUT
All component values are nominal.
absolute maximum ratings over virtual junction temperature range (unless otherwise noted)
Input voltage, V
I
:
A7924C
-40 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
All others
-35 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
150
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
-65 to 150
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
package thermal data (see Note 1)
PACKAGE
BOARD
JC
JA
Power Flex (KTE)
High K, JESD 51-5
3
C/W
23
C/W
TO-220 (KCS)
High K, JESD 51-5
3
C/W
19
C/W
NOTE 1: Maximum power dissipation is a function of TJ(max),
JA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) - TA)/
JA. Operating at the absolute maximum TJ of 150
C can affect reliability.
recommended operating conditions
MIN
MAX
UNIT
A7905C
-7
-25
VI
Input voltage
A7908C
-10.5
-25
V
VI
Input voltage
A7912C
-14.5
-30
V
A7915C
-17.5
-30
IO
Output current
1.5
A
TJ
Operating virtual junction temperature
0
125
C
A7900 SERIES
NEGATIVE VOLTAGE REGULATORS
SLVS058D - JUNE 1976 - REVISED APRIL 2004
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
electrical characteristics at specified virtual junction temperature, V
I
= -10 V, I
O
= 500 mA (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TJ
A7905C
UNITS
PARAMETER
TEST CONDITIONS
TJ
MIN
TYP
MAX
UNITS
25
C
-4.8
-5
-5.2
Output voltage
IO = 5 mA to 1 A,
P
15 W
VI = -7 V to -20 V,
0
C to 125
C
-4.75
-5.25
V
Input regulation
VI = -7 V to -25 V
12.5
50
mV
Input regulation
VI = -8 V to -12 V
4
15
mV
Ripple rejection
VI = -8 V to -18 V,
f = 120 Hz
0
C to 125
C
54
60
dB
Output regulation
IO = 5 mA to 1.5 A
15
100
mV
Output regulation
IO = 250 mA to 750 mA
5
50
mV
Temperature coefficient of output voltage
IO = 5 mA
0
C to 125
C
-0.4
mV/
C
Output noise voltage
f = 10 Hz to 100 kHz
25
C
125
V
Dropout voltage
IO = 1 A
25
C
1.1
V
Bias current
25
C
1.5
2
mA
Bias current change
VI = -7 V to -25 V
0.15
0.5
mA
Bias current change
IO = 5 mA to 1 A
0.08
0.5
mA
Peak output current
25
C
2.1
A
Pulse-testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible. Thermal effects must
be taken into account separately. All characteristics are measured with a 2-
F capacitor across the input and a 1-
F capacitor across the output.
This specification applies only for dc power dissipation permitted by absolute maximum ratings.
electrical characteristics at specified virtual junction temperature, V
I
= -11 V, I
O
= 500 mA (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TJ
A7906C
UNITS
PARAMETER
TEST CONDITIONS
TJ
MIN
TYP
MAX
UNITS
25
C
-5.75
-6
-6.25
Output voltage
IO = 5 mA to 1 A,
P
15 W
VI = -8 V to -21 V,
0
C to 125
C
-5.7
-6.3
V
Input regulation
VI = -8 V to -25 V
12.5
120
mV
Input regulation
VI = -9 V to -13 V
4
60
mV
Ripple rejection
VI = -9 V to -19 V,
f = 120 Hz
0
C to 125
C
54
60
dB
Output regulation
IO = 5 mA to 1.5 A
15
120
mV
Output regulation
IO = 250 mA to 750 mA
5
60
mV
Temperature coefficient of output voltage
IO = 5 mA
0
C to 125
C
-0.4
mV/
C
Output noise voltage
f = 10 Hz to 100 kHz
25
C
150
V
Dropout voltage
IO = 1 A
25
C
1.1
V
Bias current
25
C
1.5
2
mA
Bias current change
VI = -8 V to -25 V
0.15
1.3
mA
Bias current change
IO = 5 mA to 1 A
0.08
0.5
mA
Peak output current
25
C
2.1
A
Pulse-testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible. Thermal effects must
be taken into account separately. All characteristics are measured with a 2-
F capacitor across the input and a 1-
F capacitor across the output.
This specification applies only for dc power dissipation permitted by absolute maximum ratings.
A7900 SERIES
NEGATIVE VOLTAGE REGULATORS
SLVS058D - JUNE 1976 - REVISED APRIL 2004
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
electrical characteristics at specified virtual junction temperature, V
I
= -14 V, I
O
= 500 mA (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TJ
A7908C
UNITS
PARAMETER
TEST CONDITIONS
TJ
MIN
TYP
MAX
UNITS
25
C
-7.7
-8
-8.3
Output voltage
IO = 5 mA to 1 A,
P
15 W
VI = -10.5 V to -23 V,
0
C to 125
C
-7.6
-8.4
V
Input regulation
VI = -10.5 V to -25 V
12.5
160
mV
Input regulation
VI = -11 V to -17 V
4
80
mV
Ripple rejection
VI = -11.5 V to -21.5 V, f = 120 Hz
0
C to 125
C
54
60
dB
Output regulation
IO = 5 mA to 1.5 A
15
160
mV
Output regulation
IO = 250 mA to 750 mA
5
80
mV
Temperature coefficient of output voltage
IO = 5 mA
0
C to 125
C
-0.6
mV/
C
Output noise voltage
f = 10 Hz to 100 kHz
25
C
200
V
Dropout voltage
IO = 1 A
25
C
1.1
V
Bias current
25
C
1.5
2
mA
Bias current change
VI = -10.5 V to -25 V
0.15
1
mA
Bias current change
IO = 5 mA to 1 A
0.08
0.5
mA
Peak output current
25
C
2.1
A
Pulse-testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible. Thermal effects must
be taken into account separately. All characteristics are measured with a 2-
F capacitor across the input and a 1-
F capacitor across the output.
This specification applies only for dc power dissipation permitted by absolute maximum ratings.
electrical characteristics at specified virtual junction temperature, V
I
= -19 V, I
O
= 500 mA (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TJ
A7912C
UNITS
PARAMETER
TEST CONDITIONS
TJ
MIN
TYP
MAX
UNITS
25
C
-11.5
-12
-12.5
Output voltage
IO = 5 mA to 1 A,
P
15 W
VI = -14.5 V to -27 V,
0
C to 125
C
-11.4
-12.6
V
Input regulation
VI = -14.5 V to -30 V
5
80
mV
Input regulation
VI = -16 V to -22 V
3
30
mV
Ripple rejection
VI = -15 V to -25 V, f = 120 Hz
0
C to 125
C
54
60
dB
Output regulation
IO = 5 mA to 1.5 A
15
200
mV
Output regulation
IO = 250 mA to 750 mA
5
75
mV
Temperature coefficient of output voltage
IO = 5 mA
0
C to 125
C
-0.8
mV/
C
Output noise voltage
f = 10 Hz to 100 kHz
25
C
300
V
Dropout voltage
IO = 1 A
25
C
1.1
V
Bias current
25
C
2
3
mA
Bias current change
VI = -14.5 V to -30 V
0.04
0.5
mA
Bias current change
IO = 5 mA to 1 A
0.06
0.5
mA
Peak output current
25
C
2.1
A
Pulse-testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible. Thermal effects must
be taken into account separately. All characteristics are measured with a 2-
F capacitor across the input and a 1-
F capacitor across the output.
This specification applies only for dc power dissipation permitted by absolute maximum ratings.
A7900 SERIES
NEGATIVE VOLTAGE REGULATORS
SLVS058D - JUNE 1976 - REVISED APRIL 2004
5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
electrical characteristics at specified virtual junction temperature, V
I
= -23 V, I
O
= 500 mA (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TJ
A7915C
UNITS
PARAMETER
TEST CONDITIONS
TJ
MIN
TYP
MAX
UNITS
25
C
-14.4
-15
-15.6
Output voltage
IO = 5 mA to 1 A,
P
15 W
VI = -17.5 V to -30 V,
0
C to 125
C
-14.25
-15.75
V
Input regulation
VI = -17.5 V to -30 V
5
100
mV
Input regulation
VI = -20 V to -26 V
3
50
mV
Ripple rejection
VI = -18.5 V to -28.5 V, f = 120 Hz
0
C to 125
C
54
60
dB
Output regulation
IO = 5 mA to 1.5 A
20
300
mV
Output regulation
IO = 250 mA to 750 mA
8
150
mV
Temperature coefficient of output voltage
IO = 5 mA
0
C to 125
C
-1
mV/
C
Output noise voltage
f = 10 Hz to 100 kHz
25
C
375
V
Dropout voltage
IO = 1 A
25
C
1.1
V
Bias current
25
C
2
3
mA
Bias current change
VI = -17.5 V to -30 V
0.04
0.5
mA
Bias current change
IO = 5 mA to 1 A
0.06
0.5
mA
Peak output current
25
C
2.1
A
Pulse-testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible. Thermal effects must
be taken into account separately. All characteristics are measured with a 2-
F capacitor across the input and a 1-
F capacitor across the output.
This specification applies only for dc power dissipation permitted by absolute maximum ratings.
electrical characteristics at specified virtual junction temperature, V
I
= -27 V, I
O
= 500 mA (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TJ
A7918C
UNITS
PARAMETER
TEST CONDITIONS
TJ
MIN
TYP
MAX
UNITS
25
C
-17.3
-18
-18.7
Output voltage
IO = 5 mA to 1 A,
P
15 W
VI = -21 V to -33 V,
0
C to 125
C
-17.1
-18.9
V
Input regulation
VI = -21 V to -33 V
5
360
mV
Input regulation
VI = -24 V to -30 V
3
180
mV
Ripple rejection
VI = -22 V to -32 V, f = 120 Hz
0
C to 125
C
54
60
dB
Output regulation
IO = 5 mA to 1.5 A
30
360
mV
Output regulation
IO = 250 mA to 750 mA
10
180
mV
Temperature coefficient of output voltage
IO = 5 mA
0
C to 125
C
-1
mV/
C
Output noise voltage
f = 10 Hz to 100 kHz
25
C
450
V
Dropout voltage
IO = 1 A
25
C
1.1
V
Bias current
25
C
2
3
mA
Bias current change
VI = -21 V to -33 V
0.04
1
mA
Bias current change
IO = 5 mA to 1 A
0.06
0.5
mA
Peak output current
25
C
2.1
A
Pulse-testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible. Thermal effects must
be taken into account separately. All characteristics are measured with a 2-
F capacitor across the input and a 1-
F capacitor across the output.
This specification applies only for dc power dissipation permitted by absolute maximum ratings.